FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
2 Waterford TARA T25 Direct Vent Freestanding Gas Stove W A TERFORD TARA Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Waterford Direct Vent Freestanding Gas Stove by Waterford Irish Stoves.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 3 T ABLE OF CONTENTS Converting a Factory Built Metal Chimney .............. 22 High Elevation ...................................................... 23 System Data Chart ..........................
4 Waterford TARA T25 Direct Vent Freestanding Gas Stove This is a copy of the label that accompanies each TARA Direct Vent Freestanding Gas Stove. We have printed a copy of the contents SAFETY LABEL here for your review. The safety label is located on the inside of the drop down pedestal door.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 5 IMPORT ANT : SA VE THESE INSTRUCTIONS The TARA Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first.
6 Waterford TARA T25 Direct Vent Freestanding Gas Stove specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per the instruc- tions starting on page 9.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 7 OPTIONAL F AN INST ALLA TION for units starting with serial # 11106 to 13347 / 217000001 to present.
8 Waterford TARA T25 Direct Vent Freestanding Gas Stove INST ALLA TION 9) Connect the red wire from the thermodisc to the red wire of the speed control wire harness. 10) Connect the live black wire from power cord to the black wire of the speed control wire harness.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 9 VENTING INTRODUCTION The following vent systems in combination with the Tara Direct Vent Freestanding Gas Stove, have been tested and listed as .
10 Waterford TARA T25 Direct Vent Freestanding Gas Stove INST ALLA TION EXTERIOR VENT TERMINAL LOCA TIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(min.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 11 INST ALLA TION RESIDENTIAL AND MANUF ACTURED HOMES / MOBILE HOMES MINIUMUM HORIZONT AL TERMINA TION INST ALLA TIONS You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove.
12 Waterford TARA T25 Direct Vent Freestanding Gas Stove Diagram 4 Diagram 2a Diagram 3 HORIZONT AL INST ALLA TIONS 1) Set the unit in its desired location. Check to determine if wall studs are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 13 INST ALLA TION VERTICAL TERMINA TION WITH CO-LINEAR FLEX SYSTEM This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. The flue length must be a minimum length of 8 ' (2.
14 Waterford TARA T25 Direct Vent Freestanding Gas Stove DV ST OVE HORIZONT AL VENT KIT (#946-1 16 & #946-216) INST ALLA TION Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 15 DURA-VENT TERMINA TION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent Direct Vent System installations: horizontal termina- tion and vertical termination. Confirm the max- imum horizontal run and maximum vertical rise from the diagram on page 18.
16 Waterford TARA T25 Direct Vent Freestanding Gas Stove INST ALLA TION from the rear of the unit to the wall. It is also important to note the wall thickness. (The wall thimble is suitable for 2 x 4 or 2 x 6 wall construction.) Select the amount of vertical rise desired for "vertical-to-horizontal" type instal- lations.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 17 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI.
18 Waterford TARA T25 Direct Vent Freestanding Gas Stove INST ALLA TION RIGID PIPE VENTING - VERTICAL TERMINA TIONS for both Residential & Manufactured Homes/Mobile Homes The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 19 b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 3) With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 10" x 10" (inside dimensions) square hole.
20 Waterford TARA T25 Direct Vent Freestanding Gas Stove Diagram 9 Diagram 8: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 21 CA THEDRAL CEILINGS Round Support (RDS) & Square Support (SQS) If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.
22 Waterford TARA T25 Direct Vent Freestanding Gas Stove Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 23 Diagram 7 4) To determine the length of flex required, measure from 3" (76mm) above the top of the Flashing down to the level of the open- ing. Add to this measurement the distance from the center of the chimney to out through the wall.
24 Waterford TARA T25 Direct Vent Freestanding Gas Stove CONVERSION KIT FROM NA TURAL GAS T O PROP ANE Kit: #290-969 for TARA Gas Stove using SIT 820 NOVA Gas Valve Conversion Kit Contains: 1 910-018 .
Waterford TARA T25 Direct Vent Freestanding Gas Stove 25 8) Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit. INST ALLA TION 1) Shut off the gas supply. 2) Remove the Cast Iron Front Panel. Hold the cast iron front panel at the bottom and lift upwards and out from the stove.
26 Waterford TARA T25 Direct Vent Freestanding Gas Stove OPTIONAL FRONT GRILL 1) Remove the Cast Iron Front Panel. Catch the cast iron front panel at the bottom and lift upwards and out from the stove. Once free of the locating tabs, the panel can be dropped down; freeing it from the top of the stove.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 27 OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
28 Waterford TARA T25 Direct Vent Freestanding Gas Stove WIRING DIAGRAM - T ARA This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 29 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
30 Waterford TARA T25 Direct Vent Freestanding Gas Stove NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 31 MAINTENANCE Top View of pilot flame MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.
32 Waterford TARA T25 Direct Vent Freestanding Gas Stove Valve Bracket with Valve - Top View Screw Screw Screw Screw Stove Front MAINTENANCE VAL VE MAINTENANCE If your valve requires maintenance or replace- ment, use the following instructions. Note: Always close off the gas supply before removing the valve.
Waterford TARA T25 Direct Vent Freestanding Gas Stove 33 REPLACEMENT / SP ARE P ARTS LIST PARTS LIST 1) W260021** Front Casting (Black) 2) 280-022 Door 3) W260040/P Glass 4) 41225 Gasket for Glass 6) .
_____________________________________________________________________________________ ____________________________________________________________ _____________________________________________________.
W ARRANTY Waterford Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd.
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ .
デバイスWaterford Appliances T25-NGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Waterford Appliances T25-NGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWaterford Appliances T25-NGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Waterford Appliances T25-NGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Waterford Appliances T25-NGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Waterford Appliances T25-NGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWaterford Appliances T25-NGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Waterford Appliances T25-NGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWaterford Appliances T25-NGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。