Watlow ElectricメーカーSeries 142の使用説明書/サービス説明書
ページ先へ移動 of 8
Series 142 User ’ s Manual Safety High Limit or On-Off Heat Controller 1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580 Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507, Internet: http://www.watlow.com The Watlow Series 142 Safety Limit is a compact, environmentally protected safety limit or temperature controller.
2 ■ User’s Manual Watlow Series 142 Figure 2a — Series 142 dimensions. Installation Procedure 1. Drill two 5mm (0.187 in.) diameter holes in the desired panel location. 2. Mount the unit with two 6-32 screws, 6mm (0.25 in.) hex nut and #6 internal tooth lock washer.
Watlow Series 142 User’s Manual ■ 3 NOTE: All terminals are 4mm (1/4 in.) quick connects. Figure 3a — 120V~ power wiring (142A - _ _ _ _ - 1 _ 00). Figure 3b — 208/240V~ power wiring (142A - _ _ _ _ - 2 _ 00). Figure 3c — Reset switch. NOTE: Jumpering the reset terminals does not convert from limit to an on-off control mode.
4 ■ User’s Manual Watlow Series 142 Figure 4 — System wiring example. ∫ WARNING: Install high or low temperature limit control protection in sys- tems where an overtemperature fault condition could present a fire hazard or other hazard.
Watlow Series 142 User’s Manual ■ 5 (2072) Limit Control Mode • High limit control • Latched manual reset with ±1.7 ° C (3 ° F) hysteresis • Can only be reset when process temperature drops below limit set point. Terminals are provided for remote reset in the event of an overtemperature condition.
6 ■ User’s Manual Watlow Series 142 (2071) To order, complete the code number to the right with the information below: 1 4 2 A - _ _ _ _ - _ _ 0 0 Series 142 = Temperature safety limit, limit, lat.
Jim Boigenzahn Winona, Minnesota, USA Name of Authorized Representative Place of Issue General Manager December 2001 Title of Authorized Representative Date of Issue Signature of Authorized Representa.
8 ■ User’s Manual Watlow Series 142 automatic power reset — A feature in latching limit controllers that does not recognize power outage as a limit condition. When power is restored, the output is re-ener- gized automatically, as long as the temperature is within limits.
デバイスWatlow Electric Series 142の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Watlow Electric Series 142をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWatlow Electric Series 142の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Watlow Electric Series 142の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Watlow Electric Series 142で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Watlow Electric Series 142を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWatlow Electric Series 142の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Watlow Electric Series 142に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWatlow Electric Series 142デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。