@ WHITE-RODGERS 1F85-277 Heating & Air Conditioning 7 Day/5-1-1 Programmable/Non-programmable, Auto Changeover, Multi-Stage/Heat Pump Thermostat INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOWALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURYAND/OR PROPERTY DAMAGE.
MOUNTING AND WIRING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
WIRING DIAGRAMS = I Polarity must be observed, tf the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made, Damage to equ pment w occur when power s restored, E/W1 SYSTE 2t .
Multi-Stage Terminal Outputs Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the thermostat for use with either multi-stage electric heat systems or multi-stage gas systems. When con- figured for electric heat, the G terminal (blower/fan) will be energized on a call for heat.
Before you begin programming your thermostat, you should be familiar with its features and with the display and the location andoperation of the thermostat buttons. Your thermostat consists oftwo parts: the thermostat cover and the base. To remove the cover, pull itstraight out from the base.
CONFIGURATION MENU Press the SYSTEM button until OFF is displayed, then press the (_ and (_ simultaneously INSTALLER/CONFIGURATION MENU Press Displayed Press Q or Q Step Button(s) (Factory Default) to.
5) Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1 ° of temperature required to reach setpoint.
SPECIFICATIONS ELECTRICAL DATA Electrical Rating: 20 to 30 VAC 50/60 Hz or DC 0.05 to 1.5 Amps (Load per terminal) 2.5 Amps Maximum Total Load (All terminals combined) TH E RMAL DATA Setpoint Temperat.
PROGRAMMING YOURTHERMOSTAT This section will help you plan your thermostat's program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
OPERATION heating program period appears. The time will change in 15- minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode. 5. Press PRGM once. The currently programmed start time and setpoint temperature for the Monday's 2nd heating program period will appear.
TROUBLESHOOTING Symptom No Heat (continued) No Cool Heat, Cool or Fan Runs Constantly Possible Cause Furnace (Air Conditioner) Cycles Too Fast or Too Slow (narrow or wide temperature swing) 5. Heating system requires service or thermostat requires replacement.
TROUBLESHOOTING Symptom Forgot Keypad Lockout Code (continued) Why won't my 2nd or 3rd stage come on? Possible Cause First stage is keeping up with demand. Corrective Action (Z) and (_ and SYSTEM button at the same time to reset the lockout code, unlock the keypad and reset all configuration menu settings.
デバイスWhite Rodgers 1F85-277の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 1F85-277をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 1F85-277の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 1F85-277の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 1F85-277で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 1F85-277を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 1F85-277の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 1F85-277に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 1F85-277デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。