Xantrex Automatic Generator Start Control System AG S Owner's Manual.
2 Notice of Copyright Automatic Generator Start Control System © October 2002 Xantrex International. All rights reserved. Xantrex is a registered trademark of Xantrex International. Disclaimer UNLESS SPECIFICALL Y AGREED TO IN WRITING, XANTREX TECHNOLOGY INC.
3 INTRODUCTION Thank you for purchasing a Xantrex Automatic Generator Start Control System. Xantrex T echnology Inc. takes pride in manufacturing quality products specifically designed to meet your needs. Main Features The Automatic Generator Start Control System (AGS) auto- mati cally controls and monitors an auxiliary generator .
THINGS YOU SHOULD KNOW The Automatic Generator Start Control System (AGS) has the following features: Starts the generator automatically in response to a low battery . The AGS continuously monitors the house battery and will start the generator automatically if the battery is low .
5 THEOR Y OF OPERA TION System The AGS system, when in AUTO or AUT O QUIET TIME mode, continuously monitors the house battery and two air conditioning/heater thermostats. If the LOCAL TIME of day is not within the AUTO QUIET TIME window , it will start the generator to charge the battery or to cool or heat as required.
6 OPERA TION When it is off, the OFF light is illuminated. DEF AUL T : OFF mode. AUTO Mode In AUTO mode, the Control Module will respond to requests for generator start from a low battery condition or from an air condi- tioning demand.
7 PM Set Time Sets the LOCAL TIME, QUIET TIME “BEGIN” or QUIET TIME “END” according to the selection made by the SELECT switch. T o set a time parameter , select the hour by repeatedly pressing the SET TIME button until the correct hour light is on.
8 INST ALLA TION The Automatic Generator Start Control System (AGS) consists of two modules, the Remote Panel and the Controller . Service Precaution Labels Install service precaution labels on or near the generator and near the AGS Remote. AGS Remote Panel This AGS Remote Panel provides information and control of the Control Module.
9 #18 A WG wire should be used. The in-line connector for the Co ntroller has the following DC connections. NO. DESCRIPTION 1 ST ART : Generator start signal contact. 2 STOP: Generator stop signal contact. 3 GENERA TOR DC HOUR METER. 4 RESERVED (Future ignition lock-out).
10 ST ART ST ART COMMON POSITIVE POWER (+) BA TT SENSE POSITIVE(+) NEGA TIVE POWER/SENSE(-) THERMOST A T 1 THERMOST A T 2 THERMOST A T 1, 3 COMMON THERMOST A T 2 COMMON DC CONNECTIONS 16 pin Connector.
DA T A CABLE 4 CONDUCTOR SUPPLIED AGS CONTROLLER AGS REMOTE P ANEL 11.
12 COMMON QUESTIONS Why is the display blank except for the mode lights? If buttons are not pressed within five seconds, the Remote Panel goes into a sleep mode to conserve energy . Why is action not immediate? The Remote Panel waits 15 seconds to determine if any more changes are to be made.
13 PROBLEM No lights on the AGS Remote are on Generator automatically comes on but does not stay on. Generator turns on when batteries are charged and air conditioner/heaters are off. Generator does not automatically turn on when AGS control attempts to turn on.
14 GLOSSAR Y AGS (Automatic Generator Start Control System) A control system to automatically start the auxiliary generator in response to a low battery and/or cooling/heating demand. AGS Controller The part of the AGS Control System that connects to the wiring of the coach.
15 LIMITED W ARRANTY What does this warranty cover? This Limited W arranty is provided by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in the Automatic Generator Start Control System.
16 What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of the customer ’s electrical systems.
17 LIMITED W ARRANTY Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages, so the above limitation(s) or exclusion(s) may not apply to you.
18 Return Procedure 1. Package the unit safely , preferably using the original box and packing materials. Please ensure that your product is shipped fully insured in the original packaging or equivalent. This warranty will not apply where the product is damaged due to improper packaging.
19 SPECIFICA TIONS XANTREX P ART NUMBERS AGS System ............................................................ 84-2064-00 includes Remote Panel, Controller , and 50' data cable (4/6 con duc- tor) INST ALLA TION Mating Connector ................
Xantrex T echnology Inc . T oll free 1 800 670 0707 Direct 1 604 422 2777 F ax 1 604 420 2145 CustomerService@xantrex.com www .xantrex.com 445-0190-01-01 Rev .
デバイスXantrex Technology AGSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantrex Technology AGSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantrex Technology AGSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantrex Technology AGSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantrex Technology AGSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantrex Technology AGSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantrex Technology AGSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantrex Technology AGSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantrex Technology AGSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。