INSTALLATION, SERVICING AND USER INSTRUCTIONS For use in Great Britain and the Republic of Ireland (GB, IE) These instructions are to be left with the customer and should be read carefully and kept in a safe place.
2 Contents APPLIANCE COMMISSIONING CHECKLIST 3 GUARANTEE 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specifications 9 Site Requirements 10 Installation 12 COMMISSIONING 18 SERVICING IN.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1.1 A competent person must carry out installation and servicing. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the databadge located on a tag/chain behind the appliance.
5 USER INSTRUCTIONS 4.1 Your stove is fitted with a control valve that can be upgraded to battery powered Remote Control. This upgrade can be fitted by anyone capable of simple DIY jobs.
6 USER INSTRUCTIONS • Remove the ceramic fuel bed components and place to one side You must protect floor covers and handle the ceramic logs with care 5.3 The logs should not require cleaning: • Do not use a vacuum cleaner or brush to clean the logs • Remove any large debris by hand • Make sure no debris blocks the burner ports 5.
7 USER INSTRUCTIONS 6.5 There are two ash panels to lie across the front of the burner. • Place the panel with the flat edge facing the left side of the firebox.
8 USER INSTRUCTIONS This is a safety feature incorporated in all Gazco fires to automatically switch off the gas supply if the pilot light goes out and fails to heat the thermocouple. The surface coating on your Yeoman stove ‘burns off’ during the first 24 hours of operation on high, producing a harmless and temporary odour.
9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Model CAT. Gas Gas Type Working Pressure Aeration Injector Gas Rate m3⁄h Input kW (Gross) Country High Low Dartmoor: YM-N9201BFLUC YM-N9201BFLUCHC I 2H Naural Gas G20 20 mbar ø14.5 mm 375 0.611 6.
10 NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest editon). See Diagram 1. 1.2 Any terminal which is less than 2 metres above any access (level ground, balcony or above a flat roof to which people have access), is to be fitted with the guard.
11 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1.2 REAR FLUE 8526 Terminal dimensions: 395 x 200 x 200 mm (H x W x D) Cut to length as required on site.
12 INSTALLATION INSTRUCTIONS INSTALLATION 1.1 Your stove is fitted with a control valve that can be upgraded to battery powered Remote Control. This upgrade can be fitted by anyone capable of simple DIY jobs. Your Yeoman dealer keeps two versions of the remote: 1.
13 INSTALLATION INSTRUCTIONS INSTALLATION • Remove the remnant of cardboard • File the newly cut edges to smooth 3.5 External Fixings From outside: • Push the flue assembly through the hole unti.
14 INSTALLATION INSTRUCTIONS INSTALLATION 1 x wall plate 1 x 75mm restrictor fixing screws This kit provides the minimum materials and extra lengths can be added to the vertical and horizontal sections; refer to the next section (6) and Diagram 3. Refer to the Technical Specification page to identify when to use a restrictor.
15 INSTALLATION INSTRUCTIONS INSTALLATION Canopy Fitting 3.3 To fit the canopy to the top of the stove: • Slide the canopy over the top plate, Diagram 4 • Make sure the stove top fits into the gui.
16 INSTALLATION INSTRUCTIONS INSTALLATION • Open the door as set out in Section 5 of the Users Instructions • Remove all the protective packaging from the components The fuel bed consists of 5 logs and 2 ash panels. The logs have letters A,B,C,D and E moulded into them for identification.
17 INSTALLATION INSTRUCTIONS INSTALLATION 5.6 • Place log E across from the rear of log A to log C on the right-hand side using the shaped cut-outs as location guides. The front of the log should sit on the front ash panels and should fit tight to log C, Diagram 13 5.
18 INSTALLATION INSTRUCTIONS COMMISSIONING 1.1 Having run the gas supply to the stove: • Purge the Supply Pipe to expel any debris blocking the gas controls • Connect the gas supply to the 8mm compression elbow at the RH rear of the stove, see diagram 1 1.
19 SERVICING INSTRUCTIONS SERVICING/FAULT FINDING 1 AR0620 This stove must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations. Refer to ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS In Installation Instructions section 5 1.
20 SERVICING INSTRUCTIONS SERVICING/FAULT FINDING.
21 SERVICING INSTRUCTIONS REPLACING PARTS 1.1 All main components can be replaced without removing the stove from its installation. I T IS ESSENTIAL THAT THE GAS SUPPLY TO THE STOVE IS TURNED OFF AT THE ISOLATION DEVICE BEFORE PROCEEDING FURTHER . 1.2 If you need to remove the flue from the stove, you must replace its seals.
22 SERVICING INSTRUCTIONS REPLACING PARTS 3.3 To remove the electrode: • Disconnect the ignition lead and undo the retaining nut • Remove the electrode noting the orientation of the electrode terminal when reassembling, Diagram 4 3.
23 SERVICING INSTRUCTIONS REPLACING PARTS 4.2 • Replace with a new ignition lead following the same route as the old one • Replace the valve cover and the pilot assembly 4.3 • Check operation of the new ignition lead 5.1 The piezo assembly used on this appliance is not serviceable and is unlikely to fail.
24 SERVICING INSTRUCTIONS REPLACING PARTS • Undo the magnetic valve-retaining nut from the back of the control valve • Gently tap out the magnetic valve and replace with a new unit • Replace the retaining nut and tighten, Diagram 13 7.
25 SERVICING INSTRUCTIONS REPLACING PARTS 10.1 In order to change between gas types you need to change the following items. • Pilot Unit • Control Valve • Main Injector • Aeration Plate (if required) • Databadge The relevant parts can be ordered as a conventional kit from Yeoman.
26 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.
デバイスYeoman 8456の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Yeoman 8456をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはYeoman 8456の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Yeoman 8456の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Yeoman 8456で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Yeoman 8456を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はYeoman 8456の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Yeoman 8456に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちYeoman 8456デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。