Black BoxメーカーLE074AE-R2の使用説明書/サービス説明書
ページ先へ移動 of 26
CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.
1 FCC ST A TEMENT FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
2 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS Contents Chapter Page 1. Specifications ....................................................................................... 3 2. Introduction.....................................................
3 CHAPTER 1: Specifications Connectors — LE071A, LE073A: (1) RJ-45 male; LE171: (1) RJ-45 female, LE072A, LE074A: (1) BNC male; LE172: (1) BNC female; LE075A: (1) AUI male; LE175: (1) AUI female Size — 4.1"H x 2.4"W x 1"D (10.4 x 6.
4 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 2. Introduction 2.1 A vailable Models The following models of the Adapters and the Media Units are available: Modular Parallel Adapters: • LE071A.
5 CHAPTER 2: Introduction 2.2 Features The Adapters offer the following features: • Fits any Ethernet cable type via modular snap-on media units • Supplied with drivers for Novell ® NetWare ® (O.
6 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 3. Installation IMPOR T ANT! Make sure the computer is turned off while performing the install procedure.
7 CHAPTER 3: Installation 3.2 Connect the Network Cable Connect the network cable unit as illustrated for each model below. 3.2.1 LE071A AND LE073A For the Modular Parallel Adapter w/SPC for 10BT (LE071A) and the Modular Parallel Adapter w/EPS for 10BT (LE073A), refer to Fig.
8 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 3.2.2 LE072A AND LE074A For the Modular Parallel Adapters for BNC (LE072A and LE074A), refer to Fig. 3-3. Fig. 3-3. Connecting an RG-58/U Coaxial Cable to the Media Unit. Make sure that the RG-58A/U coaxial cable has a T-connector at the end.
9 CHAPTER 3: Installation NOTE Both ends of the T- connector must be attached to network cabling. If the Adapter is at the end of a network segment, the end of the T-connector not attached to the network must have a 50-ohm terminator installed. 3.2.3 LE075A For the Modular Parallel Adapter for AUI, refer to Fig.
10 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 3.3 Plug the Ethernet Adapter into the Computer Plug the 25-pin connector on your Modular Parallel Adapter into the parallel port at the back of your notebook/laptop computer, holding the Adapter with the logo at the top.
11 CHAPTER 3: Installation 3.5 Install the AC Power Adapter If the SPC is not used, plug the AC power adapter cable into the small round socket at the back of the Modular Media Unit, as shown in Fig. 3-6 . Plug the other end of the AC adapter cable into any standard electrical outlet.
12 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 4. Software Setup and Operation The ODI subdirectory contains the following DOS ODI files for use with Novell NetWare and other network operating systems using the ODI specifications: • LSL.COM — The Novell Link Support Layer program • SETODI.
13 • .ETHERNETPOCKET PROTOCOL.INI—Sample initialization file • .NIFSETDOS.NIF— Configuration file used by the setup program The MSLANMAN.OS2DRIVERS subdirectory contains the drivers and files for Microsoft LAN Manager OS/2 workstation. • .ETHERNETPOCKET SETNDIS.
14 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 4.2.2 C ONFIGURATION (O PTIONAL ) The SETODI is a self-configuring driver that automatically detects the correct LPT port, interrupt line, and unidirectional/bidirectional mode to be used. If you have a special configuration, you may need to override this automatic selection by using the NET.
15 4.2.3 O PERATION To start work on the NetWare workstation, run the STARTNET batch file. Then log into the network. The STARTNET.BAT file includes the following set of commands: LSL SETODI IPXODI NETX F: If you wish, you may enter these commands in the AUTOEXEC.
16 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 3. When prompted, insert the Network Drivers diskette. 4. Select “Modular Parallel Adapter” from the menu. 5. Continue with the installation until it is completed. 6. Reboot the PC. Installation for LAN Manager versions 2.
17 CHAPTER 4: Software Setup and Operation The options are as follows: • POLLING—A PC may use either IRQ-7 or IRQ-5 for handling the parallel port communications. If you need to work without interrupts (usually only with test evaluations), delete the semicolon in this line.
18 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 7. In the “Network Settings” window, choose “OK.” From the next window choose “Restart Computer.
19 CHAPTER 4: Software Setup and Operation 4.5.2 C ONFIGURATION (O PTIONAL ) SETAILAN accepts the following standard command line switches: HELP, XEROX, IEEE, MPX, PACKET_SIZE, REMOVE, VERBOSE, “?” and “@.” In addition to the standard command line switches, SETAILAN accepts the following: UNIDIR, LPTn, EPP, and DISABLELINK 4.
20 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS Hardware related switches are: UNIDIR, EPP, DISABLELINK and LPTn. The Network Drivers diskette contains the SETDIAG self-test diagnostic utility program, which tests the adapter and reports the results of the tests.
21 CHAPTER 5: Self-T est and Diagnostics To run the self-test and diagnostics program: 1. Copy the SETDIAG.* files from the supplied network drivers diskette into the network directory.
22 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS 5.1.1 A DVANCED RAM T EST The diagnostics portion of the SETDIAG program activates a brief RAM test. However, to thoroughly test the Adapter’s RAM, several time- consuming tests are required. The Advanced RAM Test option in the SETDIAG main menu activates those tests.
23 CHAPTER 6: Error Messages If problems occur during operation of your Adapter, one of the messages below will be displayed. Error messages can be recognized by the beep and the word FATAL that precedes the message. All other messages on the screen are for information only.
24 MODULAR P ARALLEL ADAPTERS AND MODULAR MEDIA UNITS While we trust that your Adapter will operate reliably over a long period of time, if you encounter any problems while using it, please perform the following steps before contacting Black Box. 1. Make sure that your adapter is properly installed, powered, and connected to the network.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1996. Black Box Corporation. All rights reserved..
デバイスBlack Box LE074AE-R2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Black Box LE074AE-R2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBlack Box LE074AE-R2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Black Box LE074AE-R2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Black Box LE074AE-R2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Black Box LE074AE-R2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBlack Box LE074AE-R2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Black Box LE074AE-R2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBlack Box LE074AE-R2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。