EN ULTRASONIC HUMIDIFIER User Manual FR HUMIDIFICATEUR À ULTRASONS Manuel d’utilisation ES HUMIDIFICADOR ULTRASÓNICO Manual del usuario DE ULTRASCHALL- LUFTBEFEUCHTER Bedienungshandbuch IT UMIDIFICATORE A ULTRASUONI Manuale d'uso NL ULTRASONE LUCHTBEVOCHTIGER Gebruikershandleiding PL NAWILŻACZ ULTRADŹWIĘKOWY Instrukcja obsługi
Model Name:
User Manual · User Manual

Français 13
Español 23
Deutsche 33
Italiano 43
Nederlands 53
Polski 63
FR Manuel d’entretien et d’utilisation
ES Guía de uso y cuidado
IT Manuale d'uso e manutenzione
NL Gebruik- en onderhoud Gids
PL Instrukcja użytkowania i pielęgnacji
DE Bedienungs- und Pflegehandbuch


Water Tank Cap PACKAGE CONTENTS
Pre-Soaked Aroma Pads (2)
circulation. Doing so may result in improper readings produced by the built-in humidity sensor.
heat exchange with outside air, water collection can occur when the humidified air touches the cold surface. In such cases, it is recommended to use in a lower mist level.


Press the power button to turn unit on. • If there is no water inside, the power button does not
turn on the Night Mood Light. The light at the bottom of the water tank will turn on, illuminating the tank. • The brightness of the light should be switched
work.
OFF > 100% > 50% > 20% > OFF > Display light Off.
mist, press the warm mist button. • Warm humidification mode is always OFF and is
the desired timer setting is lit on the display. • The programmable timer button will cycle through the
heated only when the user operates the button.
following settings: 0 hours, 2 hours, 4 hours, 8 hours, and 12 hours. To cancel the timer at any time, press the timer button until 0 hours is shown on the display.

programmable humidistat can be set in 5% increments, from 40% to 60% humidity. • Manual humidity is set in 40% > 45% > 50% > 55% > 60%
the time on the display.
humidifier will cycle off until the humidity in the room drops 5% below the set humidity level, then will cycle on until the set humidity level is reached again.
red LED indicator will continue to blink at the same time.
output. • The corresponding mist level will be lit on the display.
Each press will increase by one. • Once you reach level 5, it will repeat at level 1.
time the humidity level button is pressed.
sterilizes the flow path of the reservoir. • Power of the product is activated and turned off when
TM Technology Removes bacteria* present in water, Ensuring a safe and sanitized mist for you and your family. (*Based on independent laboratory test conducted on Escherichia coil, Staphylococcus aureus, Salmonella typhimurium, Klebsiella pneumoniae)

the potential for white dust; a deposit of minerals left behind from using hard water in your humidifier.
Installation Instructions: 1. Open the Water Tank Cap and fill the tank with water up to 'Max'. 2. Remove demineralization capsule from the package. 3. Put the capsule into the tank and wait for 10 minutes. 4. Demineralization capsule cannot be reused. If you want to place an order of our demineralization capsule, please visit www.winixeurope.eu
temperature of water you use, and the mist level setting you choose, you may experience longer or shorter runtimes.
Pre-Soaked Aroma Pads & Aroma Pad Tray
indicator. • Each press will increase by one. Once you reach level 5,
essential oil to deliver aroma into the air.
it will repeat at level 1.
Installation Instructions: 1. Turn off the humidifier. 2. Push the Oil Tray at the back of the base and pull it out. 3. Tear the pouch at the notch to expose pad, insert pad into the Aroma Tray. 4. Enjoy the refreshing aroma! The scent lasts up to 48 hours (2 full days).
360° Rotating Mist Nozzle • Rotate the mist nozzle to adjust the mist output
direction.
comfortable and quiet environment.
CAUTION 1) Contact with exposed pad may cause eye irritation. In case of contact with eyes, flush with water immediately. If eye irritation persists, consult with a doctor. 2) If you want to remove the aroma pad or if the humidifier has not been operating for a long time, clean and dry the tray and put it back in place. 3) Never put the aroma pad in the water tank.
independent Night Mood Light and control light display.
Auto Shut Off Protection
automatically.

Read all instructions before installation and use
ultrasonic membrane with their fingers, the natural oil and cosmetics on the skin can damage the surface, resulting in irregular mist output. In order to have the unit run properly after this occurs, you need to: 1. Wash the water tank and the base 2 ~ 3 times and then restart the unit. In case the unit is not washed, the unit will operate normally after running for 30 min ~ 1 hour on continuous mode. 2. If the water is not enough, the mist may not be generated properly. (This may be a defect in the air hinge or water valve) There should be at least 30 mm of water in the base after removing the water tanks.
A waterproof mat or pad is recommended for under the humidifier. A finished floor may be damaged by water or moisture exposure. • Do not reach for a unit that has fallen into water.
Unplug it immediately. • Always unplug the unit from the electrical outlet
immediately after using and before cleaning. • Do not place or store the unit where it can fall or be
pulled into a tub or sink.
Wash the nozzle, cover separately, and let tank dry in the shade
water. • Naturally occurring stains inside the tank can be
cleaned using a soft cloth. • Do not use chemicals such as bleach, abrasive, etc. to
clean.
Deep cleaning (with vinegar)
Cleaning the ultrasonic transducer
of time, be sure to dry the Mist Output completely and wipe clean. • Clean the tank, reservoir, tank cap, and transducer/
the humidifier at least once or twice a week. • Tilt it in the direction of the air
ultrasonic membrane with a 10:1 ratio mixture of water and white vinegar. • Fill the tank with diluted vinegar water to the maximum
hinge when disposing of the water in the main body. • Do not allow water into this
opening (air outlet). • Never touch the transducer/ultrasonic membrane with
your fingers; the natural oil and cosmetics in the skin can damage the surface. • Never clean the ultrasonic membrane by scraping with
for 30 to 60 minutes. • Pour out mixed water and rinse with clean tap water
a hard object. Scratching the surface of the vibrator with a sharp object may cause the Mist Output to weaken or cause failure. • Never submerge the base in water or any other liquid.
Guide bracket silencer



1 lavender and 1 eucalyptus.
Please don't put any other materials other than
Aroma Pads.
Replacing Aroma Pads

Do not pull on the power cord when unplugging the unit.
Do not tie or knot the power cord while unit is in operation.
fire. • Perform regular maintenance on the ultrasonic
If the unit becomes submerged in water, unplug it and contact customer service.
Do not unplug or move the unit while in operation.
Do not plug additional appliances into the same outlet or power supply.
Do not touch the plug with wet hands.
time. • Do not touch the water or any part of the unit that is
Unplug the unit when not in operation for extended periods of time.
Do not place around heating elements.
Do not use around mist or fumes from industrial oil or around large quantities of metallic dust.
children to use this unit without supervision. • Do not use outdoors. For indoor use only.
The cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching or placing heavy objects on it.
Do not install in any sort of motor or transport vehicle. (trucks, boats, ships, etc)
Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire.
Do not place in an area with excessive amounts of noxious gases.
with a special cord. Reassembly is available from the manufacturer or its service agent. • This appliance is not intended for use by a person
Do not place near any flammable materials. (aerosols, fuel, gases, etc)
Do not have the unit facing into wind or drafts.
(including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge about the unit, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. • Children should be supervised to ensure they do not
Do not place below any electrical outlet.
Do not place in excessively humid areas where the unit may become wet.
play with the appliance. • This unit is not intended to be used to preserve
To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
documents or for art conservation.

Thank you for purchasing a Winix Ultrasonic Humidifier. This product is for household use only. Please read all instructions carefully before operating.
Pressing the power button does not work
- Dispose the remaining water from the main body and
the water tank from previous use. Refill the water tank with new tap water.
There's no steam coming out
The Empty Tank Alarm isn't turning off
- Please fill the tank with water more than halfway. • Is the nozzle and cover well seated?
- After a few moments, the water in the water tank fills
the reservoir and the Empty Tank Alarm turns off.
- Please install the cover correctly. • Please clean the ultrasonic module.
- Drain the water inside the humidifier and place it on a
It has a strong odor
flat, stable surface.
- Clean the inside of the main body and the water tank.

The exterior, design, and product specifications may be changed without prior notice to improve product performance.
The terms of the warranty are as follows: 1. This product is manufactured under stringent quality control and inspections. 2. The warranty will be voided if product failure is a result of negligence or misuse by the consumer. Shipping and service fees may be incurred even during the warranty period. 3. A proof of purchase must be presented upon claiming a Product Warranty. 4. Store the proof of purchase in a safe place or register your product on winixeurope.eu to upload your proof of purchase. 5. This warranty is valid only in the Europe.

Benefits of WINIX Pre-Soaked Aroma Pads:
Benefits of using WINIX Demineralization Capsules:
(sold separately depending on model)
Vaporizer Scent Pads are non-medicated refill pads designed with Polymer PP to release soothing relief vapors to enhance your humidification experience and to help provide added comfort.
lifespan.
soaked aroma pad offers 48 hours of long-lasting comfort.
5 tank fillings or when you notice an increase of white residue.
to use and install, preventing messy spills and doing away with the need for constant refilling.
capsule could differ based on the quality of water.
Our humidifier helps add comfort wherever you are.
Never use water softening additives in your humidifier.


To expedite service, please specify the model name and number, the nature of the problem, your contact information, and your address.
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。