Page 1 of the Dometic Climate Control Harrier (HL36H401RI) user manual — Harrier Lite HL36H401RI, HL36H401RIY Harrier Plus HP36H401RI, HP36H401RIY
1ページ · クリックして拡大
1ページ

CLIMATE CONTROL

HARRIER

Dometic Climate Control Harrier (HL36H401RI) — CLIMATE CONTROL diagram (page 1)
図 1

Harrier Lite HL36H401RI, HL36H401RIY Harrier Plus HP36H401RI, HP36H401RIY

Air conditioning roof unit Installation Manual EN

Page 2 of the Dometic Climate Control Harrier (HL36H401RI) user manual — CLIMATE CONTROL
2ページ · クリックして拡大
2ページ

© 2020 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.

Page 4 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 2.1 Handling the device !
4ページ · クリックして拡大
4ページ

Safety and installation instructions Harrier series

2 Safety and installation instructions

Please observe the prescribed safety instructions and stipulations from the vehicle manufacturer and service workshops.

The manufacturer accepts no liability for damage in the following cases:

  • Faulty assembly or connection
  • Damage to the product resulting from mechanical influences and incorrect connection voltage
  • Alterations to the product without express permission from the manufacturer
  • Use for purposes other than those described in the operating manual

2.1 Handling the device !

  • WARNING!
  • Installation and repair of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).
  • Electrical devices are not toys. Keep electrical devices out of reach of children or infirm persons. Do not allow them to use electrical devices without supervision.
  • Persons whose physical, sensory or mental capabilities or whose lack of experience and knowledge prevent them from using the device safely should not use it without supervision or instruction by a responsible person.
  • Do not undo the upper cover of the roof air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires. !
  • CAUTION!
  • The roof air conditioner must be installed securely so that it cannot fall down.
  • Only operate the roof air conditioner if you are certain that the housing and the cables are not damaged.
  • Do not use the roof air conditioner near flammable fluids or in closed rooms.
  • Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept.
  • Do not reach into air outlets or insert any foreign objects in the device. A
  • NOTICE!
  • Only use the device as intended.
  • The roof air conditioner is not suitable for use in agricultural or construction vehicles.
Page 5 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 3 Target group for this instruction manual
5ページ · クリックして拡大
5ページ

Harrier series Target group for this instruction manual

  • Do not make any alterations or conversions to the device.
  • Never drive through automatic car washes when the roof air conditioner is mounted.
  • If faults occur in the refrigerant circuit, the system must be checked by a specialist company and repaired properly. The refrigerant must never be released into the air. I

2.2 Handling electrical cables !

  • WARNING!
  • The electrical power supply may only be connected by a qualified electrician.
  • The appliance shall be installed in accordance with national wiring regulations. !
  • NOTICE!
  • Use cable ducts to lay cables through walls with sharp edges.
  • Do not lay loose or bent cables next to electrically conductive materials (metal).
  • Do not pull on the cables.

3 Target group for this instruction manual

The instructions in this manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied.

Page 6 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 5 Accessories
6ページ · クリックして拡大
6ページ

Scope of delivery Harrier series

4 Scope of delivery

Dometic Climate Control Harrier (HL36H401RI) — 4 Scope of delivery diagram (page 6)
図 2 · 4 Scope of delivery

1 1 Roof air conditioner

2 1 Roof plate

3 1 Air distribution box (ADB)

4 1 ADB centre cover

5 5 Duct sections

6 3 Cable connectors

7 4 Fastening bolts

8 1 Remote control

5 Accessories

Available as accessories (not included in the scope of delivery):

Description Ref. no.

Extension duct sections (each section covers additional 10 mm) 4450017931

Longer fastening bolts (for 80 – 120 mm roof thicknesses) 4450012023

Page 7 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 7 Labels
7ページ · クリックして拡大
7ページ

Harrier series Intended use

6 Intended use

The Harrier series air conditioner are designed for installation on the roof of a caravan or recreational vehicle to provide reverse cycle heating and cooling. The device is intended for vehicles with roofs that are from 30 to 100 mm thick. The device must be installed so that it is within ±10° of the horizontal plane. It is not suitable for houses and apartments.

The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work properly if exposed to strong vibrations.

The function of the roof air conditioner is guaranteed for temperatures between –2 °C and 52 °C. I

Dometic Climate Control Harrier (HL36H401RI) — 6 Intended use diagram (page 7)
図 3 · 6 Intended use

7 Labels

Dometic Climate Control Harrier (HL36H401RI) — 7 Labels diagram (page 7)
図 4 · 7 Labels

Labels are attached to the Harrier series roof air conditioners. These labels provide the user and fitter with information on specifications of the device.

The roof air conditioner label is located on the side of the electronics box and can be seen through the side vent. The ADB label is located inside the centre cover.

Page 8 of the Dometic Climate Control Harrier (HL36H401RI) user manual — A
8ページ · クリックして拡大
8ページ

8 Installation !

8.1 Note on installation

Read this installation manual completely before installing the roof air conditioner.

The following tips and instructions must be observed while installing the roof air conditioner: D !

  • CAUTION! Beware of injury
  • Improper installation of the roof air conditioner can result in irreparable damage to the device and put the safety of the user at risk.
  • The manufacturer assumes no liability for malfunctions and for the safety of the roof air conditioner, especially for injury and/or damage to property, if the roof air conditioner is not fitted in accordance with these installation instructions.
  • Always wear the recommended protective clothing (e.g. protective goggles, gloves).

A

  • NOTICE! Beware of damage
  • Observe the structural engineering of the vehicle and seal of all openings made when installing the roof air conditioner.
  • Check whether the roof of the vehicle is able to support the weight of a person before climbing onto it. Ask the vehicle manufacturer about the permissible roof loads.
Page 9 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.1.2 Note on installation location
9ページ · クリックして拡大
9ページ

8.1.1 Note on transport

Dometic Climate Control Harrier (HL36H401RI) — 8.1.1 Note on transport diagram (page 9)
図 5 · 8.1.1 Note on transport
  • Pay attention to the orientation of the up arrows on the carton. Do not install the unit if it has been upside down for any period of time (fig. 4 A ).
  • Always have someone help you carry the roof air conditioner.
  • Always lift the roof air conditioner to move it and never drag it over the roof (fig. 4 B ).
  • Do not use the ventilation slots to lift it (fig. 4 C ).

8.1.2 Note on installation location

  • Before installing the roof air conditioner, check whether any vehicle components could be damaged by the installation of the roof air conditioner (such as lamps, cupboards, doors).
  • Before installation, find out (by consulting the manufacturer of the vehicle) whether the construction is designed for the static weight and the loads of the air conditioner when the vehicle is in motion. The manufacturer of the roof air conditioner assumes no liability whatsoever.
  • The vehicle manufacturer may have already provided points where the opening for the installation of the roof air conditioner can be made without any risk of weakening the construction or cutting power cables.
  • Select a flat and sufficiently level area at the centre of the vehicle roof between two longitudinal sections for installation.
  • The roof inclination of the installation surface may not exceed 10°.
Page 10 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.1.3 Note on electrical system
10ページ · クリックして拡大
10ページ
  • Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm should be kept.
  • Make sure that there are no objects within the vehicle which could obstruct the attachment of the air outlet unit or the cooled air from flowing through the swivelling air distribution nozzles.
  • For safety reasons, note the location of existing wiring harnesses, wires and other components within the installation area, in particular those which are not visible, when installing the roof air conditioner (when drilling or screwing etc.).

8.1.3 Note on electrical system

  • Only a qualified electrician should connect the roof air conditioner to the electrical power.
  • Check that the voltage specification on the type plate is the same as that of the power supply.
  • Do not lay cables which are loose or bent next to electrically conductive material (metal).
  • Install an all-pole switch with a contact opening width of at least 3 mm on the installation side.
  • Ensure that the mains voltage supply has a residual current circuit breaker.
  • Make sure that the grounding cable of the air conditioner is connected to the vehicle‘s grounding system.

There are two ways of installing the roof air conditioner:

  • Making a new opening (chapter “Making a new opening” on page 11). In this case the opening must be reinforced by an appropriate frame.
  • Using an existing opening in the vehicle such as a roof hatch or replacing an old air conditioner (chapter “Installing in an existing opening” on page 13).
Page 11 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.2 Making a new opening
11ページ · クリックして拡大
11ページ

8.2 Making a new opening

Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 11)
図 6 · 8.2 Making a new opening

See fig. 5

➤Select an area at the centre on the roof between two longitudinal supports. A

Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 11)
図 7 · 8.2 Making a new opening

➤Mark the position and size of the opening (preferably 400 x 400 mm or

optionally 360 x 360 mm).

Page 12 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.2 Making a new opening
12ページ · クリックして拡大
12ページ
Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 12)
図 8 · 8.2 Making a new opening

See fig. 6

➤Drill out the corners (A).

➤Carefully cut out the opening on the roof using a keyhole saw or a similar

tool (B).

➤Make sure no electrical power cables are damaged.

Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 12)
図 9 · 8.2 Making a new opening

See fig. 7

➤Before installation, check whether the roof hole needs reinforcing.

➤If needed, remove the foam according to the width of your reinforcing rails

(not in scope of delivery) (A).

➤Fit the reinforcing rails (B).

➤If needed, fit a suitable H-frame to provide reinforcement to the roof.

Page 13 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.2 Making a new opening
13ページ · クリックして拡大
13ページ
Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 13)
図 10 · 8.2 Making a new opening
  • NOTE
  • Existing roof hatch openings in accordance with fig. 8 are suitable for installing the roof air conditioner.
  • Dispose of all waste material, glue, silicone and seals separately. Observe the disposal guidelines.
  • The manufacturer only assumes liability for parts included in the scope of delivery. The validity of the warranty expires if the device is installed together with third-party parts.

See fig. 8

➤Remove all screws and fixtures of the existing roof hatch or air conditioner.

➤Take out the roof hatch or air conditioner.

Dometic Climate Control Harrier (HL36H401RI) — 8.2 Making a new opening diagram (page 13)
図 11 · 8.2 Making a new opening

See fig. 9

➤Remove the sealant around the opening using a scraper or similar tool.

Page 14 of the Dometic Climate Control Harrier (HL36H401RI) user manual — See fig. 0 A
14ページ · クリックして拡大
14ページ
Dometic Climate Control Harrier (HL36H401RI) — See fig. 0 A diagram (page 14)
図 12 · See fig. 0 A

See fig. 0 A

➤Seal the screw holes and recesses with a flexible non-hardening butyl sealing

compound (e.g. SikaLastomer-710, Selleys Butyl Mastic, Bostik ezycaulk butyl sealant, or similar products).

Dometic Climate Control Harrier (HL36H401RI) — See fig. 0 A diagram (page 14)
図 13 · See fig. 0 A

The roof air conditioner must be connected to an electric circuit which is able to supply the required current (see Technical data in Operating Manual).

➤Select the cross-section of the cable corresponding to the length:

– Length < 7.5 m1.5 mm² – Length > 7.5 m: 2.5 mm²
Page 15 of the Dometic Climate Control Harrier (HL36H401RI) user manual — See fig. 0 A
15ページ · クリックして拡大
15ページ
Dometic Climate Control Harrier (HL36H401RI) — See fig. 0 A diagram (page 15)
図 14 · See fig. 0 A

See fig. a

➤Make an opening on one side in order to feed through the electrical power

supply cable.

➤Feed the 240 Vw cable through the opening into the vehicle interior.

Dometic Climate Control Harrier (HL36H401RI) — See fig. 0 A diagram (page 15)
図 15 · See fig. 0 A

See fig. b

➤Orientate roof frame based on opening size.

➤Fit the roof frame into the roof opening

➤Seal around the roof frame with flexible non-hardening butyl sealing com-

pound (e.g. SikaLastomer-710, Selleys Butyl Mastic, Bostik ezycaulk butyl sealant, or similar products).

Page 16 of the Dometic Climate Control Harrier (HL36H401RI) user manual — See fig. 0 A
16ページ · クリックして拡大
16ページ
Dometic Climate Control Harrier (HL36H401RI) — See fig. 0 A diagram (page 16)
図 16 · See fig. 0 A

➤Lift the roof air conditioner onto the roof of the vehicle.

➤Position the roof air conditioner onto the roof plate and align into the groove

in the base pan. Observe the direction of travel.

Page 17 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.5.1 Attaching the roof air conditioner
17ページ · クリックして拡大
17ページ

8.5.1 Attaching the roof air conditioner

Dometic Climate Control Harrier (HL36H401RI) — 8.5.1 Attaching the roof air conditioner diagram (page 17)
図 17 · 8.5.1 Attaching the roof air conditioner

See fig. d

➤Use the corners of the front of the base pan to help align the unit with the roof

plate.

Page 18 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.5.2 Electrical connection
18ページ · クリックして拡大
18ページ

8.5.2 Electrical connection

Dometic Climate Control Harrier (HL36H401RI) — 8.5.2 Electrical connection diagram (page 18)
図 18 · 8.5.2 Electrical connection

rd rd ye bk bk bu br br wh wh

1 220 – 240 Vw mains

4 Heatsink metal net

10 Out air sensor

Show 19 more labels / short text on this page
2 Evaporator plate · 3 Communication wire · 5 Condenser plate · 6 Reversing valve · 7 Inverter compressor · 8 Fan evaporator · 9 Fan condenser · 11 Evaporator sensor · 12 Condenser sensor · 13 Discharge sensor · 14 Inductor · ye yellow · bn brown · bu blue · gn green · vt violet · rd red · wh white · bk black
Page 19 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.5.2 Electrical connection
19ページ · クリックして拡大
19ページ
Dometic Climate Control Harrier (HL36H401RI) — 8.5.2 Electrical connection diagram (page 19)
図 19 · 8.5.2 Electrical connection

➤Connect the roof air conditioner with the mains voltage supply.

Connect the cables (1) to a cable connector (2).

Page 20 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.5.4 Communication cable
20ページ · クリックして拡大
20ページ

8.5.4 Communication cable

➤Pull out the filter slightly to create a gap for the communication cable (3).

➤Feed the communication cable through the gap and locate the wire in the

opening.

Dometic Climate Control Harrier (HL36H401RI) — 8.5.4 Communication cable diagram (page 20)
図 20 · 8.5.4 Communication cable

See fig. g

➤Stack the duct sections and place against the roof thickness: the duct height

should match the roof height. Or use the below table as a guide:

Roof thickness Number of duct sections Harrier Light

Number of duct sections Harrier Plus

25. 28 mm 1 (See NOTICE on page 11) 2 (See NOTICE on page 11)
28. 38 mm 2 3
38. 48 mm 3 4
48. 58 mm 4 5
58. 68 mm 5 6 (extra duct section must be ordered)
Dometic Climate Control Harrier (HL36H401RI) — 8.5.4 Communication cable diagram (page 20)
図 21 · 8.5.4 Communication cable

➤Attach the required number of duct sections on the ADB.

Page 21 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 8.5.5 Communication cable
21ページ · クリックして拡大
21ページ

➤Fasten the ADB to the ceiling through to the roof air conditioner with the

4 bolts supplied.

Dometic Climate Control Harrier (HL36H401RI) — See fig. h A diagram (page 21)
図 22 · See fig. h A

See fig. h A

➤Tighten the screws using a torque spanner and a fastening torque of

2.5 Nm ±0.3 Nm.

8.5.5 Communication cable

➤Connect the communication 4 pin plug into the socket on the side of the

display (2) in the ADB.

➤Ensure the cable is located into the small opening away from the filter area.

➤Secure excess cable into the holders.

➤Push the filter back fully in.

Page 22 of the Dometic Climate Control Harrier (HL36H401RI) user manual — See fig. h A
22ページ · クリックして拡大
22ページ
Dometic Climate Control Harrier (HL36H401RI) — See fig. h A diagram (page 22)
図 23 · See fig. h A

See fig. i

➤Clip the centre cover to the ADB.

The installation is now completed. Connect to the power and test.

Page 23 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 9 Technical data
23ページ · クリックして拡大
23ページ

Harrier series Technical data

9 Technical data

Contains fluorinated greenhouse gases. Hermetically sealed equipment.

Harrier Lite HL36H401RI, HL36H401RIY

Harrier Plus HP36H401RI, HP36H401RIY

Compressor cooling capacity3600 W

Cooling capacity based on ISO 5151: 2413 W 3028 W

Heating capacity based on ISO 5151: 2421 W 3017 W

Rated input voltage220 V w to 240 V w / 50 Hz
Rated current cooling7.5 A 6.9 A

Rated current heating 6.1 A 5.9 A

Required fuse10 A
Operating temperature range–2 °C to +52 °C
RefrigerantR-410A
Refrigerant quantity0.650 kg 0.750 kg
CO 2 equivalent1.357 t 1.566 t
Global warming potential (GWP)2088
Protection class (outdoor unit)IPX4

Suggested max. vehicle length (with insulated walls): 7.5 m

Dimensions L x W x H (height above vehicle roof): 997 x 665 x 240 mm 1070 x 750 x 280 mm

Weight37 kg 44 kg

Inspection/certification:

Page 24 of the Dometic Climate Control Harrier (HL36H401RI) user manual — 4445102831 4450018156 554-584-MA02 04/2020
24ページ · クリックして拡大
24ページ

4445102831 4450018156 554-584-MA02 04/2020

dometic.com

YOUR LOCAL

YOUR LOCAL

YOUR LOCAL SALES OFFICE

DEALER

SUPPORT

dometic.com/dealer

dometic.com/contact

dometicĶ ,*ű0 )"0Ŗ,= "s

*+-)"1")&01*#*+"1& *+- ,&"0ķ4%& % *+-/&0"1%"*+"1& /*2-ķ , "#*2,!&,1%"-2 )& 9)&,$0*#ĸ DOMETIC GROUP AB "+3E/,0$ 1 ,ĉčŖĉďĉčČ*), 4"!",

Dometic Climate Control Harrier (HL36H401RI)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Dometic Climate Control Harrier (HL36H401RI)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Dometic Climate Control Harrier (HL36H401RI) 取扱説明書(PDF)

24 ページ·799 KB·エアコン·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…