1 This instantaneous water heater (fig. 1) is intended to provide economical heating of water sufficient for a single outlet i.e. kitchen sink or wash basin and can be installed with a sanitary water fitting.
When the hot-water tap is opened, the heater switches itself on automatically when the minimum water flow rate is exceeded and heats the water as it passes through the appliance.

The heater is pre-set in the factory to an out- let temperature of about 38 °C, which is ideal for washing your hands. When this tem- perature is reached, the electronic regulator reduces the power in order to ensure that the outlet temperature does not exceed this value. This automatic temperature regulation means that it is only necessary to open the hot water tap to obtain water at a constant, safe temperature for washing hands. On the control panel, the temperatures 35 °C, 38 °C and 45 °C can be selected. Cold water may be added if a lower temperature is required.
If the flow rate is too low, if the flow pressure is too low, or if the warm-water tap is closed, the appliance switches itself off automatically. For an optimum flow of water, always fit the special jet regulator enclosed with the appliance. This regulator is inserted into the thread on the end of the tap and fits into any standard sleeve size M 22/24.
The maximum possible outlet temperature is determined by the tem- perature of the incoming water, the rate of flow and the heating power of the heater (see diagram). The flow rate can be pre- set (“Adjusting the water flow”, 28).
max. temperature increase t1–t2 in Kelvin
3,5 kW 4,4 kW 5,7 kW 6,5 kW
1,0 1,5 2,0 2,5 3,0 3,5 4,0

Typ MCX 3 MCX 4 MCX 6 MCX 6-220 MCX 7 Art. No. 15003 15004 15006 15005 15007 Capacity Liter 0,2 Nominal pressure MPa (bar) 1 (10) Heating system Bare wire heating system IES® Required water resistance at 15 °C in Ω cm ≥ 1100 ≥ 800 ≥ 800 ≥ 800 ≥ 1100
Electric supply 1~ / N / PE 220 – 240 V AC 1~ / N / PE 220 V AC 2~ / PE 400 V AC Nominal power rating 3,5 kW 4,4 kW 5,7 kW 6,0 kW 6,5 kW Nominal current 15 A 19 A 25 A 27 A 16 A
Temperature choice 35 °C – 38 °C – 45 °C
Factory temperature setting 38 °C Maximum inlet temperature 70 °C Factory flow setting at 3 bar 2,0 l/min 2,5 l/min 3,3 l/min 4,5 l/min 3,7 l/min Maximum temperature increase at rated power and a flow rate of… 1)
2,0 l/min 25 K 31 K 41 K 43 K 46 K 2,5 l/min 20 K 25 K 33 K 34 K 37 K 3,0 l/min 17 K 21 K 27 K 29 K 31 K 3,5 l/min 14 K 18 K 23 K 24 K 26 K 4,0 l/min 12 K 16 K 20 K 21 K 23 K
Required l/min to switch on l/min 1,2 1,5
Required l/min to switch off l/min 1,0 1,3 Min. required cable size 2) mm2 1,5 2,5 4,0 4,0 2,5 Weight filled with water ca. 1,5 kg Dimensions (H × W × D) 13,5 × 18,6 × 8,7 cm Protection class acc. to VDE 1 Type of protection according to VDE IP 25


Electrical connection with mains power cable (shorten if necessary)
Top edge of wash basin approx. 850 Top edge of wash basin approx. 850
Axis wall bracket approx. 520 Axis wall bracket approx. 520
Unvented installation (closed outlet) with tap for pressurised appliances 4 Fit jet regulator:

Electrical connection with mains power cable (shorten if necessary)
Dimensions in mm · Dimensions in mm

The heater is installed as shown in the immediate vicinity of the outlet in a frost-free room. We guarantee trouble-free operation only if CLAGE fittings and accessories are used. Note the fol- lowing during installation:
The hot water temperature may not exceed 55 °C if the appliance is connected to a shower. If the appliance is operated with preheated water, it must be ensured that its temperature is also limited to 55 °C by the customer.

Installation guidelines:
Hose DN Dexternal PN Rmin 8 mm 12 mm 20 bar 27 mm Ensure sufficient equipotential bonding.
L min L min α = 90° L min α = 180° L min α = 360° 60 mm 140 mm 180 mm 260 mm




a. Seal b. Strainer c. Cold water-connection (inlet) d. Hot water-connection (outlet) e. Rating plate cover

Removing the appliance from the wall bracket
Put the wide screwdriver tip into the interlock between the water connections until it stops, then press slightly upwards (1), tilt the appliance forward by max. 15° (2) and remove it upwards (3).

Only by a specialist!
Fill the appliance completely with water by repeatedly opening and closing the hot- water tap before connecting to electrical power. The heating element may be damaged if this is not done!

9 (220 V~) MCX 6-220 (240 V~) MCX 3..6-240 (400 V 2~) MCX 7
To prevent damage to the appliance, the instantaneous water heater must be purged of air before using it for the first time.
Each time it is emptied (for example after work on the plumbing system or following repair work on the appliance), the instantaneous water heater must be purged before it is used again.
Do not switch on the electric power at this time!
Circuit diagram


The rating plate and the hood screw are located under this cover.
On the inner part of the cover, you can find the name of the appli- cation type (1), as well as the serial number (2) and the article number (3).



May only be carried out by a specialist. Remove the cover (see Fig. 10), undo the hood screw underneath and remove the hood.
Decreasing the flow rate: Turn the adjusting screw clockwise to decrease the flow rate, thus making a higher outlet temperature possible.
Increasing the flow rate: Turn the adjusting screw counter-clockwise to increase the flow rate, thus reducing the pos- sible outlet temperature.


The touch key allows you to select one of the three preset temperatures.
Every key press sets the temperature to the next level:
35 °C 38 °C 45 °C (max.)
Press the key once again starts the cycle all over.
The current selected temperature is indicated by one of three coloured LEDs.

Key lock and temperature lock
The current selected temperature setting can be locked against unintended alteration. Thus, the temperature cannot be changed by a single keypress anymore.
Activate keylock / Deactivate keylock: Press and hold touch key for approx. 5 seconds until the active LED goes out, then release the touch key.
As the control panel’s energy saving feature, the active LED turns off automatically about 20 seconds after the last operation (e.g. tapping or temperature selection).
To identify the selected setting at any time, the LED can be enabled permanently and the LED standby function will then be disabled with the following procedure:
If the tap is opened or the touch key is used in LED standby mode (LED off), the last active LED lights up (wake up), but the temperature setting will not change yet. Only when pressed once again, the temperature setting will be adjusted.
The LED Standby function can be activated in the same way again.
This function is retained even after power failure.

This product was manufactured climate neutrally according to Scope 1 + 2. We recommend the purchase of 100% green electricity to make the operation climate neutral as well.
Your product was manufactured from high-quality, reusable materials and components. Please respect in case of discarding that electrical devices should be disposed of separately from household waste at the end of their service life. Therefore, please take this device to a munici- pal collection point that return used electronic devices to the recycling system. Disposing it correctly will support environmental protection and will prevent any potential negative effects on human beings and the environment that could arise from inappropriate handling of these devices at the end of their service life. Please contact your local authority for further details of your nearest designated collection point or recycling site.
Business customers: If you wish to discard equipment, please contact your dealer or supplier for further information.
The following table will help you to determine and rectify the reasons for possible problems.
No water flows Water supply is turned off Open the main water valve and the shut-off valve
The jet regulator is not fitted Fit the special CLAGE jet regulator
Check the water flow pressure or let check the water flow adjustment by an authorized techni- cian
Water flows more slowly than expected
Water pressure is not suf- ficient
Dirt in the pipes Remove any dirt from the filter, valves and taps / check the technical data
Remove any dirt / increase the flow water pres- sure, close other taps, open the shut-off valve further
The heater switches itself on and off
Water pressure is varying, flow rate is too low
Let adjust the water flow by an authorized tech- nician, open the shut-off valve, fit the special CLAGE jet regulator, check water pressure
Water pressure is not suf- ficient
Dirt Remove dirt from the inlet and outlet
Supply voltage varies Check the supply voltage
Hot water tempera- ture varies
Water connections mixed up Check installation
Hot water tempe- rature too low and one LED flashes slowly
Adjust the flow either at the tap, the valve or have the flow adjusted by a authorized techni- cian (“Adjusting the water flow”, 28).
Flow rate is too high or inlet temperature is too low
Fault Cause Action · Water remains cold

Replace temperature sensor (authorized techni- cian)
One LED flashes rapidly and water remains cold
Defective heating element Replace heating element (authorized techni- cian)
All LEDs flash rap- idly and water gets warm
Reposition control panel connector (authorized technician)
Defective control panel cable
Replace control panel (authorized technician)
All LEDs flash rapidly and water remains cold
Defective power unit Call customer service
LED turns off shortly after keypress Keylock is active Deactivate keylock (“How to use”, 29)
Touch key was not touched in centre
LED flashes after keypress
Don‘t touch the touch key for approx. 3 seconds (until LED lights up normally); for proper han- dling, touch the touch key right in the centre Touch key calibration active
No LED lights LED Standby active Check LED by touching the touchkey. If still no LED lights up, check the fuses!
If the connection cable is damaged, it must be replaced with an original spare cable from the manufacturer by an authorised technician in order to avoid any hazards.
If you cannot rectify the fault with the aid of the troubleshooting table, please contact custo- mer service.
If you cannot rectify the fault with the aid of this table, please contact customer service.
Pirolweg 1 – 5 21337 Lüneburg Germany
We can either give you the name and address of an authorised customer service company or repair the heater ourselves. In the latter case, please send in the heater (at your cost and risk) with details of the problem and a copy of the sales invoice.
Defective temperature sen- sor · After-Sales Service



Pos. Désignation 1 Vis de réglage de la quantité d’eau 2 Capot avec clavier de commande 3 Cartouche chauffante 4 Limiteur de température de sécurité (STB) 5 Filtre 6 Raccords à eau 7 Support mural 8 Borne de sécurité de mise à la terre 9 Passe-câble
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
よくあるトラブル、考えられる原因、対処法。
| 問題 | 考えられる原因 | 対処法 | |
|---|---|---|---|
| No water flows | Water supply is turned off | Open the main water valve and the shut-off valve | p.12 |
| Water flows more slowly than expected | The jet regulator is not fitted | Fit the special CLAGE jet regulator | p.12 |
| Water flows more slowly than expected | Water pressure is not suf- ficient | Check the water flow pressure or let check the water flow adjustment by an authorized techni- cian | p.12 |
| Water flows more slowly than expected | Dirt in the pipes | Remove any dirt from the filter, valves and taps / check the technical data | p.12 |
| The heater switches itself on and off | Water pressure is varying, flow rate is too low | Remove any dirt / increase the flow water pres- sure, close other taps, open the shut-off valve further | p.12 |
| Water remains cold | Water pressure is not suf- ficient | Let adjust the water flow by an authorized tech- nician, open the shut-off valve, fit the special CLAGE jet regulator, check water pressure | p.12 |
| Water remains cold | Dirt | Remove dirt from the inlet and outlet | p.12 |
| Hot water tempera- ture varies | Supply voltage varies | Check the supply voltage | p.12 |
| Hot water tempera- ture varies | Water connections mixed up | Check installation | p.12 |
| Hot water tempe- rature too low and one LED flashes slowly | Flow rate is too high or inlet temperature is too low | Adjust the flow either at the tap, the valve or have the flow adjusted by a authorized techni- cian (“Adjusting the water flow”, 28). | p.12 |