

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
OperaƟ ng Temperature -20o to 50oC
-5o to 120oF
Environmental ProtecƟ on RaƟ ng IP67
Input Voltage 12 V DC
EsƟ mated baƩ ery run Ɵ me at 100% brightness at 60% brightness
Weigh only 12 hours 16 hours Weigh/Read 6 hours 8 hours Read only 3 hours 4 hours
To ensure opƟ mum performance of the TWR-ϧ, the internal baƩ ery may need to be charged for up to 16 hours before fi rst Ɵ me use.


> About > BaƩ ery.
or too cold (below 0oC). The Scale will keep operaƟ ng while plugged in but will not charge properly unƟ l at room temperature.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
Find animal Look up and add animal to a session
On-screen Help Touch to display informaƟ on about the current screen

Touch Screen Tap the screen icons, fi eld names or buƩ ons to view or enter data.
Weigh buƩ on Records animal weight
Power buƩ on
Zero buƩ on Sets the displayed weight to zero.
Home BuƩ on Return to the Home screen
NavigaƟ on keys These buƩ ons can be used to navigate the funcƟ ons of the scale as an alternaƟ ve to the touch screen.
Bluetooth status BaƩ ery charge indicator

Weighing mode AUTO - AutomaƟ c weight lock MAN - Manual weight lock

Antenna connecƟ on (for panel reader antenna)
BaƩ ery charger
USB port (connect to PC)
USB port (for memory sƟ ck) Serial port (mini adapter supplied to change connector sex)
Loadbar connecƟ ons

Gallagher TWR-ϧ Weigh Scale Quick Start Guide

The TWR-ϧ can be placed on a table top or mounted on the bracket supplied.
The bracket can be mounted on a fl at verƟ cal surface, a round post, or a rail.
To mount the bracket on a fl at verƟ cal surface, or a round wooden post, use the 4 x tek screws included with the unit.


To mount the bracket on either a verƟ cal or horizontal bar, use the ‘U’ bolts included with the unit.


Gallagher TWR-ϧ Weigh Scale Quick Start Guide
If using loadbars, follow these steps: 1. Select a weighing site that provides a solid, level and well drained surface. 2. Ensure the loadbars and plaƞ orm are well secured and clear of any obstrucƟ ons. 3. Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and plaƞ orm sit fl at without any rocking or twisƟ ng to avoid weighing inaccuracies. Note: It may be necessary to shim the loadbars or plaƞ orm to ensure there are no twisƟ ng pressures within the plaƞ orm. Weights should be evenly distributed over the top of the weigh bars. 4. For Wired Loadbars: Connect the loadbar cables to the TWR-ϣ. For Wireless Loadbars: The TWR-1 must be within 8-10m of the loadbars. Refer to the Gallagher Loadbars InstrucƟ ons for further installaƟ on informaƟ on. A beep will sound indicaƟ ng a successful connecƟ on/disconnecƟ on of the loadbars.


Gallagher TWR-ϧ Weigh Scale Quick Start Guide
The TWR-5 has an internal reader, that when connected to a Gallagher Antenna panel will capture the Electronic ID tag data.
To weigh animals in a crush, you will need:
To mount your Antenna panel, refer to the instrucƟ ons included with the panel.

MounƟ ng bracket
Amphenol connector (2.)
MounƟ ng holes
MounƟ ng holes
Amphenol connector · Antenna Cable

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
The fi rst Ɵ me the TWR-ϧ is powered on, the First Time Start-Up screen will display. Tap the screen to update the language, Ɵ me, date and weight fi elds as required and then tap Save.

To change any of these seƫ ngs later, they can be accessed via Seƫ ngs
on the right of the Home screen.
For more informaƟ on about this screen or any TWR-ϧ screen, tap
displayed in the top right corner of the screen. This will display the On-screen Help with more informaƟ on about what you see on the screen.
When the TWR-ϧ is leŌ idle for more than 30 minutes it will automaƟ cally shutdown to preserve the baƩ ery.
Press the Power buƩ on to turn the unit back on.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
1. On the TWR-5, tap Seƫ ngs > Equipment ConnecƟ ons > Loadbars > Wireless. 2. The TWR-5 will search for the loadbars. When the loadbars have been located, tap to select them from the list, then tap Connect. Note: As per the Wireless Loadbar InstallaƟ on instrucƟ ons, your loadbars must be switched on and in range to display in the search list. 3. The connecƟ on process will take up to 30 seconds while pairing occurs between the loadbars and the TWR-5. Once completed, tap Done.
> Equipment ConnecƟ ons > EID Reader. 8. Select how the Reader is being connected. This will be by Bluetooth, Serial cable, USB or using the internal reader (Panel). If using the internal reader, a successful connecƟ on will show as
in the footer bar. Note: A mini serial adapter is included with the TWR-ϧ if a female serial connecƟ on is required.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
Refer to Bluetooth – Connect EID Reader in the TWR-5 On-screen Help or your EID Reader User Manual for further informaƟ on on pairing the reader.
Connecting to a Drafter/Sorter To connect the TWR-ϧ to a draŌ er, use the data cables supplied with your draŌ er. Refer to your DraŌ er User Manual for more informaƟ on. 1. Turn On the TWR-ϧ.
> Equipment ConnecƟ ons > DraŌ er. 3. Specify the type of draŌ er that is being connected, to complete the setup.
If your draŌ er is not listed, tap Create Custom and follow the confi guraƟ on wizard set up your draŌ er.
When you gather informaƟ on about an animal, it is recorded in a Session. Each event such as weighing, adds a record to the current session. A template using pre-determined defaults can be set up and used each Ɵ me you start a new session. Note: It is recommended a new session is opened for a new day’s acƟ vity or for a new group of animals. An animal cannot appear within the same session more than once. To start a new weighing session:

To customize the session: click on the OPTIONS buƩ on at the lower leŌ of the screen. Here you can set up the weighing mode, draŌ ing opƟ ons, traits and name for the session. Refer to Session OpƟ ons (p. 11) for more informaƟ on.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
If weighing in MAN - Manual weight lock, you must fi rst press Weigh
. When the weight becomes stable, it will lock.
aŌ er a successful weight lock.
Reading tags with the Internal Reader
When the internal reader is connected it will display as
in the screen footer. • If no loadbars are detected, the internal reader will always be acƟ ve, ready to
read a tag and will display as
unƟ l a weight is detected on the plaƞ orm.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
, as it reads the tag. The internal reader will go in and out of acƟ ve mode as it detects weight on the weighing plaƞ orm.

The Session OpƟ ons menu is used to confi gure seƫ ngs for the current session.
From this screen, tap the required opƟ on to change the session name, turn draŌ ing On or Off , add traits to the session, change the weight lock mode and confi gure Advanced seƫ ngs.
Tap Save to keep any changes.
for step by step informaƟ on to set up draŌ ing, add traits to the session or to confi gure the Advanced seƫ ngs. New traits are set up in the Seƫ ngs menu before they can be added to a session.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
The informaƟ on collected during a session can be viewed from the session’s Weigh screen.

To view informaƟ on about all the animals in the session;
tap All Animals,

to view weight range of animals.
To view informaƟ on about an individual animal weighed;

Tap an animal VID to view this animal on the Weigh screen.

to view the history of weights for the selected animal, from the Weigh screen.

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
Download the Gallagher Animal Performance app from Google Play or the App Store.
If required, follow the prompts and create a Gallagher Account.
The TWR-ϧ is a tough and reliable product designed for use in typical livestock environments. Proper care and maintenance can extend its life.
It is important to update the TWR-ϧ soŌ ware from Ɵ me to Ɵ me to ensure you have the latest enhancements. Updates are regularly released to enhance the features of the scale or to correct issues. These updates can be accessed by signing into Gallagher Animal Performance on your PC:

Gallagher TWR-ϧ Weigh Scale Quick Start Guide
This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collecƟ on point for the recycling of waste electrical and electronic equipment. The separate collecƟ on and recycling of your waste equipment at the Ɵ me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more informaƟ on about where you can drop off your waste equipment for recycling, please contact your local city recycling offi ce or the dealer from whom you purchased the product. FCC
This device complies with Industry Canada licence-exempt RSS standard(s). OperaƟ on is subject to the following two condiƟ ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operaƟ on of the device. Under Industry Canada regulaƟ ons, this radio transmiƩ er may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmiƩ er by Industry Canada. To reduce potenƟ al radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communicaƟ on. This radio transmiƩ er (IC: 7369A-G0260X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna Types: - BR600 Small Antenna Panel (G03121) - BR1300 Large Antenna Panel (G031424) - Sheep Auto DraŌ er Antenna Panel (G05714)
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use by Gallagher Group Limited is under license. Other trademarks and trade names are those of their respecƟ ve owners.
Industry Canada
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。