72 Battery Operated 4-Wire Operation Millivolt Compatible Digital Display DC V oltage Comp atible S tage: 1-Heat, 1-Cool Easy Slide Switch Operation USERS INFORMA TION MANUAL MODEL TST ATBBNQ001 NON-PROGRAMMABLE DIGIT AL THERMOST AT NOTE TO INST ALLER: This manual must be left with the equipment user .
P age 1 Ta ble Of Content s LOCA TION OF CONTROLS DISPLAY NORMAL OPERA TION PREP ARA TION REMOVE OLD THERMOSTA T WIRE CONNECTIONS JUMPER CONFIGURA TION TEST OPERA TION TROUBLESHOOTING W ARRANTY 2 4 5 .
TST A TBBNQ001 Safety W arnings P age 2 CAUTION Follow Installation Instructions carefully . DISCONNECT POWER T O THE HEA TER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOST A T AND INST ALLING THE NEW THERMOST A T . W ARNING The 2 Alkaline “AA” batteries must be replaced at least every 12 months to assure proper operation.
Location of Controls P age 3 MODE SWITCH Heat, Cool or Off On or Auto FAN SWIT CH UP & DOWN BUTTONS 72.
Display P age 4 Current room temperature. If the Up or Down arrow buttons are pressed the thermostat will show the desired Set T emp temperature indicator . Once this screen is reached you may use the Up or Down arrow buttons to adjust the desired room temperature.
P age 5 Normal Operation Manual Operation Select heat or cool with the mode switch. Normally leave the fan switched to auto. In fan auto, the fan will turn on only with a heat or cool demand. When Fan On is selected, the fan will run continuously , even when the mode switch is set to Off .
Step #1 Prep aration P age 6 These tools will be required: Flat Blade Screwdriver Wire cutter & S tripper Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermost at. Carefully unpack the thermost at.
P age 7 Step #2 Remove & Replace Old Thermost at Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away . Disconnect the wires from the old thermostat.
P age 8 The top of the thermostat housing has two (2) screw- driver slots to assist when seperating. Repeat the procedure in the other screw driver slot. Separate the housing halves by pulling the top forward until the pins release, and then lift the bottom out.
P age 9 Battery Replacement REPLACE WITH A LKALINE BA TTERIES A T LEAST ONCE EVER Y YEAR, OR WHEN THE “LOW BA TTER Y” ICON APPEARS (pages 2,8). USE “ AA ” SIZE ALKALINE BA TTERIES USE “ AA .
72 Heat Off Cool Fan On FanA uto If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below , or the wiring diagrams that follow . Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked Y1 or Y Cooling Y Power Rh, R, M, V r , A R B B Rev .
Sample Wiring Diagrams FA N COOLING POWER W G R Y W Y B O G R 4 Wire, 1 St age Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat * , Electric Cool, split systems & package units P age 11 GAS OR ELECTRIC HEA T 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 12 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with O reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE O * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration.
P age 13 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with B reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE B * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration.
P age 14 Sample Wiring Diagrams FA N POWER G R W W Y B O G R 3 Wire, 1 St age Heat Residential Gas or Electric Heat units with a separately controlled fan. GAS OR ELECTRIC HEA T 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 15 Sample Wiring Diagrams POWER W R W Y B O G R 2 Wire, 1 St age Gas Heat Residential Gas or Millivolt units. GAS OR ELECTRIC HEA T 2 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 16 Sample Wiring Diagrams FA N COOLING POWER G R Y W Y B O G R 3 Wire, 1 St age Cooling Residential Electric Cool units 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 17 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are shown in the factory default positions for typical gas furnace heating with electric cooling.
P age 18 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper is used to select Fan On (G) with Heat (W). Jumper shown in the factory default position.
P age 19 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are used to select heat pump operation. Note: Thermost at Does Not Have Auxiliary Heat / Emergency Heat Capability . Leave jumpers in original factory default positions (figure-A) for non heat pump applications.
P age 20 Step #5 T est Operation Adjust the Slide Switch until it is located under the word HEA T on the thermostat. Press the Up or Down buttons until the set temperature is 10 degrees above room temperature. The HV AC unit should energize in the heating mode (pages 4-5).
P age 21 T roubleshooting SYMPTOM: The slide switches on the thermostat are very difficult to move. CAUSE: The backplate of the thermost at is deformed by being screwed tightly into a wall that is not perfectly flat. REMEDY : Loosen the screws holding the thermostat into the wall.
P age 22 T roubleshooting 4Z95 72 Heat Off Cool Fan On FanA uto C c F FOR HOME OR OFFICE USE T ested to Comply with FCC S tandards Battery S tat TST A TBBNQ001 SYMPTOM: The heating does not attempt to turn on. CAUSE: The heating setpoint is set too low or the Mode Switch is not set for Heat, or the batteries are too weak.
THIS WARRANTY DOES NOT INCL UDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping , servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer .
デバイスBryant TSTATBBNQ001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant TSTATBBNQ001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant TSTATBBNQ001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant TSTATBBNQ001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant TSTATBBNQ001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant TSTATBBNQ001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant TSTATBBNQ001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant TSTATBBNQ001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant TSTATBBNQ001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。