72 74 70 C OOL H EAT AUTO Mo I2:00 Heat P ump & Heat Cool Meets California T itle 24 Residential Dual Setpoint 5+2 Day Programmable 4 T ime periods V ery Easy to Program Easy T o Read Display Ther.
Ta ble Of Content s FRONT P ANEL DISPLAY QUICK STA RT Set the clock and go BASIC OPERA TION PROGRAMMING 4 Time Periods ADV ANCED SETUP ABOUT ADV ANCED OPERA TION W ARRANTY P age 1 CAUTION Follow Installation Instructions before proceeding . SET THERMOST AT T O MODE “ OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR REST ORING F ACTORY DEF AUL TS.
72 74 70 C OOL H EAT AUTO Mo I2:00 Front Panel P age 2 Liquid Cryst al Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Heat = Red, Cool = Green 1 2 3 4 5 2 3 4 5 .
1 2 4 3 Mode Indicators Selects the operation mode of the equipment. HEA T - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies.
5 6 7 8 Morning, Day , Evening & Night Indication Indicates the program time period. Page 8-1 1. Setup Indication Indicates the thermostat is in the programming mode. Page 12. Fan Operation Indication Fan On - indicates constant, continuous fan operation.
During Setup & Programming: Pressing the Mode button selects different flashing items. (Represented in dark black ) Pressing the Up and Down buttons will modify the flashing selection. Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to enter Setup screens.
The HEA T setting indicates the temperature the r oom has to reach befor e the furnace will turn on to heat the room. The COOL setting indicates the temperature the r oom has to reach befor e the air conditioner will turn on to cool the room. OFF indicates both heating and air conditioning systems are turned off .
buttons. In any mode, adjust the desired Set T emperature with Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously . Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature.
Programming 4 T ime periods P age 8 Press Press Press Press Press the Mode button. While holding the Mode, press the Up button for 2 seconds to enter time period programming. Continued Select the Day of the Week. MoTuW eThFr or SaSu. (Weekday or Weekend schedule) Adjust the start time for Morning.
MODE Programming 4 T ime Periods P age 9 Press Press Press Press Press Continued Adjust the start time for Day . Adjust the cooling setpoint for Day . (35 - 99) Adjust the start time for Evening. Adjust the cooling setpoint for Evening. (35 - 99) Adjust the heating setpoint for Day .
Programming 4 T ime Periods P age 10 Press Press Press Press Continued Adjust the start time for Night. Adjust the cooling setpoint for Night. (35 - 99) Adjust the heating setpoint for Evening. (35 - 99) MODE MODE MODE MODE Adjust the heating setpoint for Night.
Programming 4 T ime Periods P age 11 Press MODE Press the Mode button. While holding the Mode, press the Up button for 2 seconds to exit time period programming.
Advanced Setup P age 12 Press Press Press Continued Adjust the time of day clock. Select the day of the week. Press the Mode button. While holding the Mode, press the Fan button for 5 seconds to enter Setup screens. NOTE: Each step # is located at the top right corner of the display for easy reference.
Advanced Setup P age 13 Press Press Press Press Continued Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) Select Electric Heat On or Off. (S tep 5 only appears if heat pump is off in step 3) Adjust the minimum difference between cooling & heating setpoints.
Advanced Setup P age 14 Select the display back- light always On , or Off after 8 seconds. On Off Select thermostat operation in degrees F ahrenheit or C entigrade. C F Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to leave the Setup screens.
Advanced Setup P age 15 S tep # Description Range Factory Default 1 T ime of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Heat Pump Off / On Off 4 Reversing V alve polarity O / .
About Advanced Features & Operation P age 16 2 ST AGE OPERA TION - The 2nd S tage of heat or cool is turned on when ( 1 ) the 1st S tage has been on for a minimum of two minutes, and ( 2 ) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees.
About Advanced Features & Operation P age 17 ELECTRIC HEA T - Selecting Electric Heat on, page 13, step 5 , will cause the thermostat to turn on the fan any time there is a heat demand. Since all control the fan, this feature should be off is only electric.
About Advanced Features & Operation P age 18 KEYP AD LOCK - T o prevent unauthorized use of the thermostat, the front panel buttons may be disabled. T o disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together .
About Advanced Features & Operation P age 19 DUAL SETPOINT BEHA VIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade.
P age 20 About Advanced Features & Operation F ACTOR Y DEF AUL TS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Down button for 2 sec.
P age 21 P/N 88-347 Rev . 1 W arranty Five- Ye ar Warranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation , whether or not actual use begins on that date, then the product does meet this warranty .
デバイスBryant TSTATBBPB501の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant TSTATBBPB501をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant TSTATBBPB501の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant TSTATBBPB501の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant TSTATBBPB501で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant TSTATBBPB501を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant TSTATBBPB501の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant TSTATBBPB501に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant TSTATBBPB501デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。