T304 T604 T904 T302 T602 T902

T 604

Keep this manual for future reference ©2022 Powersoft

DO000239.01 R0

Page 2 of the Powersoft Power Amplifier (T902) user manual — CLASS3
2ページ · クリックして拡大
2ページ

Important Safety Instructions

Powersoft Power Amplifier (T902) — Important Safety Instructions diagram (page 2)
図 2 · Important Safety Instructions

Common symbols and meanings

Please read and keep all safety and use instructions.

THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE USER TO THE RISK OF ELECTRIC SHOCK.

This product is intended for installation by professional installers only! This document is intended to provide professional installers with basic installation and safety guidelines for this product in typical fixed-installation systems. Please read this document and all safety warnings before attempting installation.

THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO ALERT THE USER TO IMPORTANT OPERATING OR MAINTENANCE INSTRUCTIONS.

THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT TO ALL THE APPLICABLE EUROPEAN DIRECTIVES

1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this equipment near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding- type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

SYMBOL FOR EARTH/GROUND CONNECTION.

SYMBOL INDICATING THAT THE EQUIPMENT IS FOR INDOOR USE ONLY.

SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF THE EUROPEAN PARLIAMENT ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).

0 °C OPERATING TEMPERATURE RANGE: 0°C TO +35°C - DERATING ABOVE 35°C.

+35 O C

85% % STORAGE RELATIVE HUMIDITY RANGE: 10% TO 85% HUMIDITY (NON CONDENSING).

DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.

DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL SKILLED PERSON ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.

DO NOT USE THIS AMPLIFIER IF THE ELECTRICAL POWER CORD IS FRAYED OR BROKEN.

TO AVOID ELECTRICAL SHOCK, DO NOT TOUCH ANY EXPOSED SPEAKER WIRING WHILE THE AMPLIFIER IS OPERATING.

DO NOT SPILL WATER OR OTHER LIQUIDS INTO OR ON THE AMPLIFIER.

THIS DEVICE MUST BE POWERED EXCLUSIVELY BY EARTH CONNECTED MAINS SOCKETS IN ELECTRICAL NETWORKS COMPLIANT TO THE IEC 364 OR SIMILAR RULES

DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO CLEAN ANY PART OF THE AMPLIFIER

POWERSOFT SUGGESTS TO PLUG THE T SERIES TO A 16 A RATING, C OR D CURVE, 10 KA SECTIONING BREAKER.

OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO THESE TERMINALS REQUIRES INSTALLATION BY AN INSTRUCTED PERSON AND THE USE OF READY MADE LEADS.

CLASS3

WIRING

PROPERLY FIT THE AC MAINS PLUG TO THE AMPLIFIER INLET. BEFORE POWERING THIS AMPLIFIER, VERIFY THAT THE CORRECT VOLTAGE RATING IS BEING USED.

TAKE CARE TO LOCK THE OUTPUT TERMINAL BEFORE SWITCHING THE DEVICE ON.

VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF SATISFYING THE POWER RATINGS OF THE DEVICE.

NO NAKED FLAME SOURCES SUCH AS LIGHTED CANDLES SHOULD BE PLACED ON THE AMPLIFIER.

IT IS HIGHLY RECOMMENDED TO UNPLUG THE OUTPUT CONNECTORS BEFORE PROCEEDING WITH THE SELF CHECK PROCEDURE

THE TESTING SIGNALS MIGHT CAUSE LOUDSPEAKER IMPAIRMENTS.

TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY RACK MOUNTED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.

THIS EQUIPMENT SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 2 M

Warranty and Technical Service

This product is covered by a limited warranty.

THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED TO PERSONS, THINGS OR DATA DUE TO AN IMPROPER OR MISSING GROUND CONNECTION.

This Powersoft product contains no user-serviceable parts. All warranty repairs must be carried by a certified technician operating in a Powersoft Authorized Service Centre. Contact The Authorized Service Center For Ordinary And Extraordinary Maintenance. To learn more about warranty terms and conditions, visit powersoft.com/warranty For any service related enquiry, please visit powersoft.com/en/product-repair/

IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL REQUIREMENTS OF SAFETY AND, IN CASE OF DOUBT, REQUIRE AN ACCURATE CHECK BY QUALIFIED PERSONNEL.

Safety Warnings · 10%

Page 3 of the Powersoft Power Amplifier (T902) user manual — Regulatory Compliance Statements
3ページ · クリックして拡大
3ページ

EC Declaration Of Conformity

Regulatory Compliance Statements

ManufacturerPowersoft S.p.A. via E. Conti 5 50018 Scandicci (Fi) Italy

Europe If the time arises to dispose of your product, please recycle all possible component.

This symbol indicates that when the end-user wishes to discard this product, it must be sent to separate collection facilities for recovery and recycling. By separating this product from other household-type waste, the volume of waste sent to incinerators or land-fills will be reduced and natural resources will thus be conserved. The Waste Electrical and Electronic Equipment Directive (WEEE Directive) aims to minimise the impact of electrical and electronic goods on the environment. Powersoft S.p.A. comply with the Directive 2012/19/EU of the European Parliament on waste electrical finance the cost of treatment and recovery of electronic equipment (WEEE) in order to reduce the amount of WEEE that is being disposed of in land-fill site. All of our products are marked with the WEEE symbol; this indicates that this product must NOT be disposed of with other waste. Instead it is the user’s responsibility to dispose of their waste electrical and electronic equipment by handing it over to an approved reprocessor, or by returning it to Powersoft S.p.A. for reprocessing. For more information about where you can send your waste equipment for recycling, please contact Powersoft S.p.A. or one of your local distributors.

We declare that under our sole responsibility the products: Model Names: T152, T154,

T302, T304, T602, T604, T902, T904 Intended use: Professional Audio Amplifier

Are in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives: 2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive 2011/65/EU RoHs Directive

USA FCC Supplier’s DeclaraƟon of Conformity Responsible Party: Powersoft S.p.A. Via Enrico Conti, 5 50018 Scandicci (FI) – Italy Phone: +39 055 735 0230 Fax: +39 055 735 6235 FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

The following harmonized standards are applied: EN 55032:2015, EN 55032:2015 /A11:2020 EN 55035:2017, EN 55035:2017 /A11:2020 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61000-3-11:2000 EN 62368-1:2014 EN 62368-1:2014 /AC:2015

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit
  • Different from that to which the receiver is connected. WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures
Powersoft Power Amplifier (T902) — Regulatory Compliance Statements diagram (page 3)
図 3 · Regulatory Compliance Statements

Marco Cati Quality & Process Manager

Canada Canadian CauƟon This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1)This device may not cause interference. 2)This device must accept any interference, including interference that may cause undesired operation of the device. WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures ICES-003 Class A NoƟce This Class A digital apparatus complies with Canadian ICES-003. RadiaƟon Exposure Statement This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

For compliance questions only[email protected]

Scandicci, January 2021

Page 4 of the Powersoft Power Amplifier (T902) user manual — Output connections
4ページ · クリックして拡大
4ページ

Preliminary operations

Digital Audio Input connection

Package list The box contains the following: 1x T Series amplifier. 3x IEC power cords (region specific) 1x Documentation folder

Digital input is supported via AES3 (AES/EBU) and Dante™ standard protocols. The AES3 input is on a standard Neutrik XLR female. The AES3 connection carries a channel pair through a 110 Ω nominal impedance wire in the form of a balanced (differential) digital signal: in AES3 XLR connectors the identification of hot and cold pins is not an issue; take care to never tie pin 2 or pin 3 (balanced signals) to pin 1 (ground). There is also a fault tolerant active repeater for the AES3 input available on a Neutrik XLR male connector. T Series amplifiers accept 4 Dante/AES67 channels over two Neutrik Ethercon connectors. There are three operating modes: 2in x 2out @ 96kHz (default), 4in x 4out @ 48kHz, 4in x 0out @ 96kHz. Cabling must comply to TIA/EIA-568-B and adopt the T568B scheme pinout. A computer running DanteTM Controller can be used in order to configure audio networking. DanteTM Controller is a software application that manages devices on the network. T Series amplifiers are automatically discovered and displayed in DanteTM Controller with the default identifier: MODELNAME-SERIAL (e.g. T602-00042069).

Location Install your T Series Amplifier in well ventilated rack cabinets. Secure both front and rear brackets to the rack. Connect the AC Mains connector to a circuit breaker. Install the amplifier far from EMF emitting devices. Avoid placing the amplifier close to heat generating sources. Cooling The ventilation openings must not be impeded by any item, keep a distance of at least 50 cm from the front and rear ventilation openings of the amplifier. T Series implements a forced-air cooling system to maintain constant operating temperatures. Air enters from the front panel, exiting at the back of the amplifier. The cooling system features variable-speed DC fans controlled by the heat sink mounted sensors. This ensures that fan noise and internal dust accumulation are kept to a minimum. In the rare case of overheating, the amplifier is protected by limiting the output power to levels that can be sustained at the actual ambient temperature. T Series amplifiers can be stacked one on top of the other, leave one rack unit empty every four to guarantee adequate air flow. Cleaning Use a dry cloth for cleaning the chassis and the front panel. Air filter cleaning should be scheduled in accordance with the dust levels in the amplifier’s operating environment. In order to take out the filters remove the 2 front covers by unscrewing the two T8 Torx screws. Use compressed air to remove the dust from filters, or wash it with clean water (let the filters dry thoroughly before reinstalling them).

Basic Operations

Front Panel

The T Series’ front panel features a high brightness 1.8” TFT Color display, 8 RGB backlit pushbuttons, and a USB port.

Navigating the menu

Get acquainted with the menu structure printed on the foldout cover of this guide. When entering the various screens some of the buttons will be lit, indicating the availability of a usable function. The 4 buttons closest to the display are used to select the channel(s), multiple channels can also be selected at once. When the cogwheel icon

is shown on the top right corner of the display, pressing and holding the top right botton 2 for 2 seconds will prompt the options menu. The leftmost pushbuttons 5 are used to navigate through the different screens. The CH3 3, CH4 4 buttons are sometimes used to cancel or confirm actions. The rightmost pushbuttons 6 are used to edit values. If held pressed they will accelerate and speed up the process.

AC Mains Supply

T Series amplifiers implement a universal switching mode power supply with power factor correction operating in the range from 100 VAC up to 240 VAC ±10%. AC mains connection is in the rear panel through the IEC C20 inlet, the approved power cord is provided.

Switching the amplifier On

Connections

Once properly powered (power cord inserted, sectioning breaker closed), if it was ON when it lost power, then the amplifier will turn ON and pass audio within 10 s. In order to toggle the amplifier between ON and STANDBY keep pressed button 1 for 2 seconds.

Signal Grounding There is no ground switch or terminal on the T Series amplifier. The unit’s signal grounding system is automatic. In order to limit hum and/or interference entering the signal path, use balanced input connections. In the interests of safety, the unit MUST always operate with electrical safety earth connected to the chassis via the dedicated Protective Earth wire.

Output Mute

Through this page, it is possible to mute each channel independently. In order to mute a channel (or a pair of bridged/joined channels) simply press the channel button. The VU meter will be replaced by a “MUTE” text and the channel pushbutton’s color will turn to amber.

Input connections

Speaker Level

  • 2 x XLR female (Analog input 1, and 2)
  • 2 x XLR male (Analog 1 and 2 link output) Four channel version

A gain value appears on the screen and the amplifier’s CH numbers are replaced with the speaker’s letters. By pressing the channel button the outputs that are part of the same speaker are selected, the channel buttons will blink and a value text is highlighted. Press the edit buttons 6 in order to edit the selected values Press and hold the cogwheel button 2 to activate the stepsize selection screen, and use the edit buttons 6 to toggle between 0.1, 0.5, 1.0dB increments.

  • 4 x XLR female (Analog input 1, 2, 3, and 4)

Output connections

Two channel version, right to left:

  • 2 x Speakon NL-4 (channel 1+2 and channel 2+n.c.) Four channel version, right to left:
  • 2 x Speakon NL-4 (channel 1+2 and channel 3+4)

Two channel version

Page 5 of the Powersoft Power Amplifier (T902) user manual — Network Configuration
5ページ · クリックして拡大
5ページ

Speaker Delay

Node Info

Through this screen, it is possible to display node information. Use the edit buttons 6 to navigate the available pages. If the cogwheel button 2 is pressed for more than 2 seconds a submenu will open, containing the following: “LOCK INTERFACE“, “LCD BRIGHTNESS“, “REMOVE GROUPS”, “RESET PROCESSING”. LOCK INTERFACE: Local lock screen, enter a 6 digit password to lock. The locked screen shows only the main view, the standby and navigation buttons are disabled. (Passepartout: 441144) LCD BRIGHTNESS: Choose between 3 different display brightness levels. REMOVE GROUPS: Removes the amplifier from any group, removes also the processing associated with that group. One typical use for this function is to remove any group that is present within the amplifier from any previous operation, while preserving the preset and the snapshot list. RESET PROCESSING: Reset to the factory default processing parameters (unmuted outputs, straight signal routing, no crossovers, EQ=flat, input to output gain=32dB, no limiters, and delay=0ms).

A delay value appears on the screen and the amplifier’s ch numbers are replaced with the speaker’s letters. By pressing the channel button the outputs that are part of the same speaker are selected, the channel buttons will blink and a value text is highlighted. Press the edit buttons 6 in order to edit the selected values. Press and hold the cogwheel button 2 to activate the stepsize selection screen, use the CH1 1 button to toggle between the available units (s, m, ft), and use the edit buttons 6 to toggle between 0.1, 0.5, 1.0, 10 ms; 0.1, 0.5, 1.0, 10 ft; 0.1, 0.5, 1.0, 10 m increments.

Matrix

The selected input appears on the screen and the amplifier’s ch numbers are replaced with the speaker’s letters. By pressing the channel button the outputs that are part of the same speaker are selected, the channel buttons will blink and a value text is highlighted. Press the edit buttons 6 in order to choose between the following: INPUT 1, INPUT 2, INPUT 3, INPUT 4, INPUT 1+2, INPUT 3+4. Press and hold the cogwheel button 2 to activate the custom mix screen, where it is possible to mix the inputs independently.

FW Update

Updating the firmware can be done through Armonía. During the firmware update, the display will show an “Updating Firmware” message, and a bar will show the progress through the various phases.

Source Select

The active sources of the 4 inputs appear on the screen and the amplifier’s ch numbers are replaced with the input numbers. By pressing any channel button its input priority list is selected, pressing the CH1 button 1 will toggle the backup state (ON/OFF). Press the CH2 button 2 to scroll through the sources (ANL, AES3, DNT). Press the edit buttons 6 in order to move the selected source in the list.

Networking T Series amplifiers support Dante networking. The two-gigabit ports internally connected via a Gigabit switch to simplify wiring and eliminate the need for external network switches in small systems. Control and audio are flowing on both ports. The amplifier can be configured for redundancy using AES3 and/or analog inputs; it can also use a redundant source device on Dante. However, it can’t use two audio networks, so never connect a T Series to the secondary network if there is one in the system.

Snapshot

Through this screen. it is possible to recall a snapshot from the local memory. Press and hold the CH2 pushbutton 2 to activate the preview mode.

IP Addressing Factory default network settings are AUTO IP. STATIC IP policy can also be adopted and configured through ArmoníaPlus or the display panel. Both ArmoníaPlusand the T Series must belong to the same subnet. If a DHCP server is not active within the network, the amplifier platform initiates a stateless address auto-configuration (i.e. Zero- configuration networking methodology – Zeroconf): it self assigns a local numeric network address (of the type 169.254.x.y with a subnet mask 255.255.0.0) and automatically distributes and resolves the hostnames of the networking devices.

Output Config

Through this screen, it is possible to Bridge/Unbridge the outputs of the T Series amplifier. Pressing any of the CH buttons will select the related channel. Joined channels must be split prior to performing briging/unbridging.

Speaker Preset

As a rule of thumb, turn the DHCP server on before connecƟng the amplifiers.

Through this screen, it is possible to check the presets that are currently loaded onto each channel. Presets can be sourced both from the internal memory and from an external USB drive. Preset selection is a guided configuration through which the amplifier will ask the user to select the brand, the family, the model, and its application. Once the application is selected and confirmed, channel buttons 1/2/3/4 1 →4 buttons can be used to select the output channel onto which the preset should be loaded.

When the amplifier discovers a DHCP server on the network, it negotiates the networking parameters.

ArmoníaPlus System Manager ArmoníaPlus System Manager is the default interface that allows system setting and customization of the T Series amplifiers. ArmoníaPlus can be installed on a PC running Windows (XP SP3 and higher). Download ArmoníaPlus System Manager for free from the dedicated website:

Network Configuration

This screen portrays the amplifier’s current network configuration. The CH4 pushbutton is lit and can be used to change the configuration. Use the CH1 1 and CH2 2 buttons to choose between “AMP STATUS” and “DANTE STATUS” respectively. It’s then possible to toggle between “AUTO IP” and “STATIC IP”, when the latter is selected, the CH1 1 and CH2 2 buttons are used to navigate across the digits, whilst the edit buttons 6 are used to edit the single digits.

https://www.powersoft.com/en/software/armoniaplus/

Page 6 of the Powersoft Power Amplifier (T902) user manual — Pinouts
6ページ · クリックして拡大
6ページ

Pinouts

Powersoft Power Amplifier (T902) — Pinouts diagram (page 6)
図 4 · Pinouts
Page 7 of the Powersoft Power Amplifier (T902) user manual — T304 - T604 - T 904
7ページ · クリックして拡大
7ページ

Front Panel

Powersoft Power Amplifier (T902) — Front Panel diagram (page 7)
図 5 · Front Panel
Powersoft Power Amplifier (T902) — Front Panel diagram (page 7)
図 6 · Front Panel

Rear Panel

T302 - T602 - T902

Powersoft Power Amplifier (T902) — T302 - T602 - T902 diagram (page 7)
図 7

8 7 10 14 16 12 9 13 15 11

T304 - T604 - T 904

Powersoft Power Amplifier (T902) — T304 - T604 - T 904 diagram (page 7)
図 8

8 7 10 14 12 16 9 13 11 15

Powersoft Power Amplifier (T902) — T304 - T604 - T 904 diagram (page 7)
図 9
Powersoft Power Amplifier (T902) — T304 - T604 - T 904 diagram (page 7)
図 10

7 CH1 (1+/-) | CH2 (2+/-) CH1 (1+/-) | CH2 (2+/-)

8 CH2 (1+/-) | n.c. (2+/-) CH3 (1+/-) | CH4 (2+/-)

Page 8 of the Powersoft Power Amplifier (T902) user manual — SPEAKER PRESET
8ページ · クリックして拡大
8ページ

Menu system

MAIN VIEW

: Press and hold the CH2/Cogwheel button for 2 seconds.

OUTPUT MUTE

SPEAKER LEVEL

SOURCE SELECT

SPEAKER CONFIG

Load to single Outputs Custom

SPEAKER PRESET

Brand Family Model Application Load to Outputs

Dante Status NET CONFIG

Mode Amp IP Mode Enter SM Enter IP Enter GW Enter SM

2s Remove Groups LCD Brightness Reset Processing NODE INFO

Show 15 more labels / short text on this page
2s · Step Size · 2s · 2s SPEAKER DELAY · Step Size · 2s MATRIX · Custom Matrix · 2s SNAPSHOT · Preview · 2s · Reset · 2s Reset · 2s · Amp Status · Local Lock
Page 9 of the Powersoft Power Amplifier (T902) user manual — POWERSOFT.COM
9ページ · クリックして拡大
9ページ

DRIVING HUMAN AUDIO EXPERIENCE

POWERSOFT S.P.A.

Via E. Conti, 5 - Scandicci (FI) 50018 - Italy

support@powersoft.com

+39 055 73 50 230

+39 055 73 56 235

POWERSOFT.COM

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Powersoft Power Amplifier (T902)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Powersoft Power Amplifier (T902)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Powersoft Power Amplifier (T902) 取扱説明書(PDF)

42 ページ·1.6 MB·アンプ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…