GEN2000LP 2000 Surge Watts / 1350 Running Watts LPG PORTA BLE GENER ATOR INST RUC TION M A NUAL READ A LL INSTR UCTIONS AND WAR NINGS BEF ORE U SING T HIS PROD UCT . This manual provides important information on proper ope ration & maintenance. Every e ffort has been made to ensure the accu racy of this manual.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 2 Model GEN2000LP 20 00 Surge Watts / 1350 Running W att s LPG (Liquid Pr opane) Por t able Generator This unit is a LPG driven generator. FEATURES: • 20 00 Surge Output • 1350 Running Watts • 120 Volt Operation • 2.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 3 TABLE OF C ONTENTS RECOGNIZ E SAFETY S YMBOLS, WORDS AND LAB ELS .............................................................................................. 4 PACKAGE C ONTENTS PACKAGE C ONTENTS .
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 4 RECOGN IZE SAFETY SYMBOLS, WORDS AND LABEL S What You Need to Know About S af ety I nstructions Warni ng and Imp ortant Saf ety Ins tructi ons ap pearin g in thi s ma nual ar e not me ant to cover al l pos sible co nditions and situatio ns that may occur.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 5 Legal Requirements: Federal and/or State Occupational Safety and Health Administration (OSHA) regulati ons, local codes, and/or ordinances may apply to the intended use of this generator.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 6 High Temperatures: This gener ator produces heat whe n in operation. Temperatures near the exhaust can exceed 150 Degrees Fahrenheit (65 Degrees Celsius). • Do not touch hot surfaces.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 7.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 8 In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 9 PACKAGE CONTENTS The following items are supplied with this Model GEN2000 LP 20 00 Surge Watts / 1350 Running Watts Portable LP Generat or. Verify that all items are included.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 11 The Air Filter is not adjustable. Tampering with the governor can damage your generator and your electrical devices, and will void your warranty. To prevent electrical shock from faulty appliances, the generator should be grounded.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 12 PREPARING THE GENERATOR FOR USE Using this Ge nera tor for the Firs t - Time STOP! The following section describes the required steps for preparing this generator for the first use.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 13 Step 2 – Connect Fuel Sulfur, water, dust, etc. are harmful for engine. If t he gas supply source (LPG) contains these harmful elements, user must use filt er to remove sulfur, water etc.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 14 Step 3 - Ground the Generator Failure t o properl y ground this generator can r esult in elec trocution. Ground this generator by tightening the grounding nut against a grounding w ire as illustrated in Figure 3.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 15 Ground this generator by tightening the grounding nut against a grounding w ire as previously illustrated in Figure 3. A general ly acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 16 USING THE GENERATOR After the engine has been running for several minutes, electrical devices may be connected t o this generator. AC Usage Electrical devices running on AC current may be connected according to their wattage requirements.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 17 Connec t electrical devices to this generator according to the follow ing procedure: 1. Allow the engine to run for several minutes after it has been st arted. 2. Confirm that the electrical device is sw itched off prior to plugging it into this generator.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 18 Device Requirem ents Max. Cord L en gth (ft) by W ire G aug e Amps Watts (120V) Watts (240V) #8 w i re #10 wi re #12 wi re #14 wi re #16 wi re 2.5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 19 MAINTENANCE/CARE Proper routine maintenance of this generator is essential for safe, economical, and trouble - free operation. It will help prolong the life of this generator as well as help reduce air pollution.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 20 Figure 11 - Checking the Oil Changing/Adding Oil The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is l ow, add oil until the l evel is sufficient to operate this generator.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 21 Air Filt er Maintenan ce Routine maintenance of the air filter helps maintain proper airflow to t he carburetor. Occasionally verify that the air filter is free of excessi ve dirt.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 22 STORAGE/TRANSPORT PROCEDURES Never place any type of storage cover on this generator while it is still hot. When transporting or storing this generator for extended time: • Allow generator to fully cool before moving it.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 23 TROUBLESHOOTING IMPORTANT: If trouble persists, call our customer help line at 1 - 866 - 460 - 9436, Monday - Fr iday, 8 AM - 4 PM Central Time. Symptom Cause Solution Engine will not start.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 24 SPECIFICATIO NS Model GEN2000 LP 40 00 Surge Watts / 3250 Running Watts Portable LP Generator Generator Type Brushless, R.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 25 PARTS DIAGRAM.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 26 PARTS DIAGRAM.
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Man ual 27 201 4 08.
デバイスBuffalo Tools GEN2000LPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Buffalo Tools GEN2000LPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBuffalo Tools GEN2000LPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Buffalo Tools GEN2000LPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Buffalo Tools GEN2000LPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Buffalo Tools GEN2000LPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBuffalo Tools GEN2000LPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Buffalo Tools GEN2000LPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBuffalo Tools GEN2000LPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。