BunnメーカーFMD-4の使用説明書/サービス説明書
ページ先へ移動 of 45
OPERA TING & SERVICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .
2 INTRODUCTION This equipment dispenses hot beverages or soups on demand from powdered product. It is for indoor use only on a sturdy counter or shelf.
3 00656.0000 00831.0000 28368.0000 USER NOTICES (Cont.) FMD-5 28964.0003 FMD-4 28964.0004 35135 012103.
4 INITIAL SET -UP 1. Locate the drip tray assembly inside the dispenser door . 2. Remove the drip tray and the drip tray cover and set them aside. ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power sour ce until specified in Initial Set-Up.
5 INITIAL FILL & HEA T CAUTION - The dispenser must be disconnected from the power sour ce throughout the initial set-up, except when specified in the instructions. 1. Turn-on the water supply and connect the dispenser to the power source. 2. Water will automatically flow into the tank to the proper level and then shut-off.
6 COLD BEVERAGE SET -UP (OPTIONAL) Cold beverages may be dispensed from the left dispense position. Simply place the HOT/COLD switch near the left whipper chamber in the “COLD” (upper) position. CLEANING Refer to the decal on the rear of the dispenser door for cleaning recommendations and proccedures.
7 DRAINING THE HOT W A TER T ANK CAUTION - The dispenser must be disconnected from the power sour ce throughout these steps. 1. Disconnect the dispenser from the power source. 2. Place the tank heater switch in the “OFF” position. 3. Shut-off and disconnect the incoming water supply.
8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
9 TROUBLESHOOTING (cont.) PROBLEM Product will not dispense (cont.) Water is not hot PROBABLE CAUSE 5. Solenoid Valve (Inlet) 6. Control Board #1 and Probe 7. Auger Drive 8. Water Strainer 9. Lime build-up CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions.
10 TROUBLESHOOTING (cont.) PROBLEM Water is not hot (Cont.) Spitting or excessive steaming Dripping from dispense tip Water flows into tank continuously PROBABLE CAUSE 4. Tank Heater Switch 5. Relay (120V versions only) 6. Control Board #2 (120V versions only) 1.
11 TROUBLESHOOTING (cont.) PROBLEM Product overflows container Weak product PROBABLE CAUSE 1. Dispense Switch 2. Dispense Solenoid Valve 1. Water Temperature 2. Whipper Motor 3. Frother 4. Dispense Solenoid Valve 5. Auger Drive 6. Auger Spring 7. Auger Motor 8.
12 TROUBLESHOOTING (CONT .) PROBLEM Dispenser is making unusual noises Excess dust Display not lit PROBABLE CAUSE 1. Plumbing Lines 2. Water Supply 3. Tank Heater 1. Fan 1. Lamp 2. Lamp Holder 3. Starter - Lamp 4. Ballast REMEDY Plumbing lines should not be rest- ing on the counter top.
13 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.
14 SERVICE AUGER DRIVE COMPONENTS - FMD-4 (CONT .) 5. Check the voltage across the positive (red wire) terminal and the negative (black wire) terminal on the auger motor with a voltmeter. With the rinse/ run switch in the run (lower) position press and hold the dispense switch.
15 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) RED to BRN/WHI from Control Board #1 J3-3 RED to WHI/RED from Control Board #1 J3-2 RED to WHI/ORN from Control Board #1 J3-1 RED to WHI/YEL from Control Board #2 J3-3 BLK to GRN from Control Board J3-4 P1639 FIG.
16 SERVICE (cont.) AUGER DRIVE COMPONENTS - FMD-4 & FMD-5 (cont.) 4. Disconnect the dispenser from the power supply. If voltage is present as described and the auger does not turn, replace the auger motor . If voltage is not present as described, refer to the wir - ing diagrams and check the dispenser wiring harness.
17 SERVICE (cont.) AUGER DRIVE COMPONENTS - FMD-4 & FMD-5 (cont.) Auger Drive Motor (Refer to Fig. 5) 1. Remove all hopper assemblies (20) and set aside for reassembly. 2. Remove the four #8-32 screws securing the hop- per support plate (19), remove plate and set aside for reassembly.
18 J4 J1 J2 J3 J4 J1 J2 J3 Location The front door lamp ballast is located behind the front access panel on the left front side of the compo- nent bracket. T est Procedure 1. Disconnect the dispenser from the power source. 2. Disconnect the two black lead on the ballast from the main harness.
19 J1 J2 CONTROL THERMOST A T - FMD-4 & FMD-5 FIG. 9 CONTROL THERMOST A T P2635 Location The control thermostat is located at the upper left rear of the dispenser housing. Test Procedure 1. Disconnect the dispenser from the power source. 2. Disconnect the black wire of the control thermo- stat from the black lead from the limit thermostat.
20 J4 J1 J2 J3 J4 J1 J2 J3 5. Reconnect the six pin connector of the wiring harness to J3 of the control board. 6. Disconnect the four pin connector from J4 of control board #1. 7. Check the voltage across pins 1 & 4 of the four pin connector on the wiring harness with a voltmeter.
21 SERVICE (cont.) 16. Reconnect the ten pin connector of the wiring harness to J2 of control board #1. 17. Gently pull the liquid level probe out of the tank lid and inspect for corrosion. Replace it if necessary. 18. Place the probe so that neither end is in contact with any metal surface of the dispenser.
22 J4 J1 J2 J3 J4 J1 J2 J3 Tank Heater Relay Control Circuitry (Control Board #2)(120V dispensers only): 1. Disconnect the dispenser from the power source. 2. Disconnect the six pin connector from J3 of con- trol board #2. 3. Check the voltage across pins 5 & 6 of the six pin connector on the wwiring harness with a voltme- ter.
23 PLACE CUP HERE PLACE CUP HERE PLACE CUP HERE PLACE CUP HERE PLACE CUP HERE RELEASE BUTTON WHEN CUP IS 2/3 FULL ! WARNING H O T L I Q U I D PUSH and HOLD BUTT ON UNTIL CUP IS 2/3 FULL, THEN R ELEASE.
24 SERVICE (cont.) DISPENSE SWITCHES (cont.) 7. Check for continuity across the terminals (top right to top left; bottom right to bottom left) of the dispense switch with the switch in the “ON” posi- tion. Continuity must not present when the switch is in the “OFF” released position.
25 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) FA N FIG. 15 F AN Location: The fan is located inside the dispenser housing on the center rear of the dispenser base plate. T est Procedures: 1. Disconnect the dispenser from the power source. 2. Disconnect the black and white wires from the fan terminals.
26 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) FROTHER AND WHIPPER MOTOR - FMD-4 (shown) & FMD-5 FIG. 17 FROTHER AND WHIPPER MOTOR Location: The frothers are located behind the dispenser door , mounted on the front panel inside the whipper cham- ber .
27 SERVICE (cont.) FROTHER AND WHIPPER MOTOR - FMD-4 (shown) & FMD-5 (cont.) FIG.19 WHIPPER MOTOR TERMINALS P1221 4. Disconnect vacuum hose (12) from fan baffle (13). 5. Remove the steam collector (1) by pulling it for- ward and at the same time twisting it clockwise.
28 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) INCREASE/DECREASE SWITCH FIG. 20 INCREASE/DECREASE SWITCH P2635 Location: The increase/decrease switch is located on the lower left front of the whipper motor mounting panel. T est Procedure: 1. Disconnect the dispenser from the power source.
29 PUSH and HOLD BUTTON UNTIL CUP IS 2/3 FULL, THEN RELEASE RINSE RINSE LAMP HOLDERS FIG. 22 LAMP HOLDERS P2638 3 4 6 5 1. Door Assy 2. Lamp Holders 3. Lamp 4. Upper Panel 5. Lower Panel 6. Starter W/Socket 2 1 Location: The lamp holders are located on the front of the upper panel behind the display panel.
30 9. Reconnect the plug on the door wiring harness to the connector on the door interconnect wiring harness. 10. Install the door lower panel (5) using six #8-32 screws. LAMP ST AR TER and SOCKET (Refer to Fig. 22) Location: The lamp starter (6) is located inside the door assy (1) on the top of the door lower panel (5).
31 SERVICE (cont.) LIMIT THERMOST A T FIG. 23 LIMIT THERMOST A T P2635 Location: The limit thermostat is located in the center of the tank lid. T est Procedures: 1. Disconnect the dispenser from the power source. 2. Disconnect both black wires from the limit ther - mostat.
32 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) P2635 RINSE/RUN SWITCH FIG. 25 RINSE/RUN SWITCH Location: The rinse/run switch is located on the lower center of the whipper motor mounting panel. T est Procedures: 1. Disconnect the dispenser from the power sour ce.
33 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) FIG. 27 HOT/COLD SWITCH P2635 HOT/COLD SWITCH (Optional) Location: The hot/cold switch is located on the left side of the whipper motor mounting panel. T est Procedure: 1. Disconnect the dispenser from the power source.
34 J4 J1 J2 J3 J4 J1 J2 J3 SOLENOID V AL VE (COLD WA TER - OPTIONAL) FIG. 29 COLD WA TER SOLENOID V AL VE P2635 Location: The cold water solenoid valve is located on the left side of the dispenser base just behind the compo- nent bracket. Test Procedures: 1.
35 J4 J1 J2 J3 J4 J1 J2 J3 SOLENOID V AL VE (DISPENSE) - FMD-4 & FMD-5 FIG. 31 DISPENSE SOLENOID V AL VE Location: The dispense solenoid is located on the upper left center of the tank. T est Procedures: 1. Disconnect the dispenser from the power source.
36 SERVICE (cont.) FIG. 32 DISPENSE SOLENOID V AL VE TERMINALS P1672 Removal and Replacement: 1. Remove the four #8-32 screws securing the side access panel to the housing. Remove panel and set aside. 2. Remove the wires from the solenoid valve. 3. Turn-off the water supply to the dispenser.
37 J4 J1 J2 J3 J4 J1 J2 J3 P2641 FIG. 34 INLET SOLENOID V AL VE TERMINALS SERVICE (cont.) WHI from Main Harness 7. Disconnect the dispenser from the power source.
38 Removal and Replacement: 1. Disconnect the dispenser from the power source. 2. Disconnect the water supply tube on the tank lid. 3. Disconnect the black wires on the limit thermstat. 4. Disconnect the black wire and the white or red wire from the tank heater terminals.
39 J4 J1 J2 J3 J4 J1 J2 J3 SERVICE (cont.) FIG. 38 T ANK HEA TER SWITCH TERMINALS P1219 BLK to Main Harnesss BLK from Main Harness FIG. 37 T ANK HEA TER SWITCH T ANK HEA TER SWITCH P2635 Location: The tank heater switch located inside the dispenser on the upper right of the front panel.
40 J4 J1 J2 J3 J4 J1 J2 J3 TANK HEATER RELAY (120V Dispensers only) FIG. 39 TANK HEATER RELAY P2635 Location: The tank heater relay is located behind the lower front access cover, mounted on the left rear side of the component bracket. Test Procedure: 1.
41 J4 J1 J2 J3 J4 J1 J2 J3 TRANSFORMER FIG. 41 TRANSFORMER P2635 Location: The transformer is located behind the lower front access cover, mounted on the right rear side of the component bracket. Test Procedure: 1. Disconnect the dispenser from the power source.
42 GRN GRY WHI/GRY BRN/BLK BRN/BLK BLK I N C D E C INCREASE/ DECREASE SWITCH RINSE/PROGRAM/ RUN SWITCH RUN RUN PGM PGM RINSE RINSE WHI/VIO RED/BLK GRN GRN GRN GRN GRY PNK WHI/ORN WHI/ORN WHI/RED WHI/R.
43 GRN GRY WHI/GRY BRN/BLK BRN/BLK BLK I N C D E C INCREASE/ DECREASE SWITCH RINSE/PROGRAM/ RUN SWITCH RUN RUN PGM PGM RINSE RINSE WHI/VIO RED/BLK GRN PROBE GRN GRN GRN GRY PNK WHI/ORN WHI/ORN WHI/RED.
44 GRN GRY WHI/GRY BRN/BLK BRN/BLK BLK I N C D E C INCREASE/ DECREASE SWITCH RINSE/PROGRAM/ RUN SWITCH RUN RUN PGM PGM RINSE RINSE WHI/VIO RED/BLK GRN GRN GRN GRN GRY PNK WHI/ORN WHI/ORN WHI/RED WHI/R.
45 GRN GRY WHI/GRY BRN/BLK BRN/BLK BLK I N C D E C INCREASE/ DECREASE SWITCH RINSE/PROGRAM/ RUN SWITCH RUN RUN PGM PGM RINSE RINSE WHI/VIO RED/BLK GRN PROBE GRN GRN GRN GRY PNK WHI/ORN WHI/ORN WHI/RED.
デバイスBunn FMD-4の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bunn FMD-4をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBunn FMD-4の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bunn FMD-4の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bunn FMD-4で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bunn FMD-4を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBunn FMD-4の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bunn FMD-4に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBunn FMD-4デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。