BunnメーカーTB3Q-LPの使用説明書/サービス説明書
ページ先へ移動 of 27
TB3Q TB3Q-LP OPERA TING & SERVICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .
Page 2 CONTENTS User Notices .................................................................... 3 Electrical & Plumbing Requirements ............................... 4 Initial Set-Up ...............................................................
Page 3 W ARNING ! Fill water tank before turning - on - thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not use near combustibles.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specified in Initial Set-Up. 120V model brewers require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. "A" model brewers require 2-wire, grounded service rated 230 volts ac, 10 amp, single phase, 50 Hz.
Page 5 INITIAL SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the Initial Set-Up, except when specified in the instructions. 1. Remove the top lid from the brewer . 2. Rotate the control thermostat knob fully counter clockwise to the "OFF" position and replace the top lid.
Page 6 37236 050305 AUTO SWEETENER SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the Initial Set-Up, except when specified in the instructions. 1. Remove the top lid and both rear panels. 2. Make sure the brewer water supply is off.
Page 7 ADJUSTING BREW VOLUMES CAUTION - Disconnect the power sour ce from the brewer prior to the removal of any panel for the replacement or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply , the tank is properly filled, and a funnel and server are in place.
Page 8 OPERA TING CONTROLS A. ON/OFF Switch ON - Placing the switch in the left position allows the start switch to activate a timed brew cycle for three gallons of tea.
Page 9 37236 080504 TEA BREWING 1. Begin each brew cycle with a clean empty brew funnel and server . (Be sure the ser ver lid doesn’t inter fere with the flow of dilution water .) 2. Insert a BUNN® filter into the funnel. 3. Pour the packet of loose fresh tea leaves into the filter .
Page 10 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
Page 11 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) Water is not hot Dilution cycle will not start Inconsistent beverage level in dispenser 6. Brew Timer 7. Brew Solenoid Valve 1. Limit Thermostat CAUTION - Do not eliminate or by- pass limit thermostat or thermal cut-off.
Page 12 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Consistently high or low beverage level in the dispenser Spitting or excessive steaming Drip-out time too long Sweetener is not working 1.
Page 13 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Water flows into tank continuously (ON/OFF Switch "ON") (UNSWEET/OFF/SWEET Switch in "UNSWEET" or "SWEET" position) Water flows into tank continuously (ON/OFF Switch "OFF") (UNSWEET/OFF/SWEET Switch in "OFF" position.
Page 14 TROUBLESHOOTING (cont.) PROBLEM Weak beverage (cont.) Dr y tea leaves remain in the funnel Brewer is making unusual noises PROBABLE CAUSE 4. Funnel Loading 5. Water T emperature 6. Low Brew Water V olume 1. Funnel Loading 1. Solenoid(s) 2. Plumbing Lines 3.
Page 15 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y .
Page 16 SERVICE (cont.) BREW SOLENOID V AL VE FIG. 2 BREW SOLENOID V AL VE P3046 Location: Viewing the brewer from the top, the brew sole- noid valve is mounted on the right side of the brewer. Test Procedures: 1. Disconnect the brewer from the power source.
Page 17 SERVICE (cont.) DIGIT AL BREW TIMER FIG. 4 DIGIT AL BREW TIMER P3047 Location: The timer is located inside the hood, on the left side. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.
Page 18 SERVICE (cont.) TL1 - WHI to Power Cord (100V & 120V) or RED to Power Connector (230V) and WHI to On/Off Switch (100V & 120V) or RED to On/Off Switch (230V) TL2 - WHI/VIO to Brew Solenoid and WHI/VIO to On/Off Switch TL3 - WHI/ORN to Start Switch TL4 - WHI/GRN to Brew Solenoid TL5 - WHI/YEL to Start Switch FIG.
Page 19 SERVICE (cont.) CONTROL THERMOST A T FIG. 6 CONTROL THERMOST A T P3047 Location: The control thermostat is located inside hood on the right side. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Locate the blue/black wire on the control thermo- stat.
Page 20 SERVICE (cont.) LIMIT THERMOST A T FIG. 8 LIMIT THERMOST A T P3047 Location: The limit thermostat is located inside the hood on the tank lid. T est Procedure: 1. Disconnect the brewer from the power source and remove the black wire from the limit thermostat.
Page 21 SERVICE (cont.) ON/OFF SWITCH FIG. 10 ON/OFF SWITCH P3034 Location: The ON/OFF switch is located in the front of the hood, above and to the left of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. Remove the black and white/violet wires from the switch terminals.
Page 22 If continuity is present as described, reconnect the wires, the switch is operating properly . If continuity is not present as described, replace the switch. Removal and Replacement: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the hood and gently push the switch through the opening.
Page 23 FIG.15 UNSWEET/OFF/SWEET SWITCH TERMINALS P1763 37236 050305 SERVICE (cont.) UNSWEET/OFF/SWEET SWITCH (Sweetner Option) FIG. 14 UNSWEET/OFF/SWEET SWITCH P3034 Location: The UNSWEET/OFF/SWEET switch is located in the front of the hood, above and to the left of the brew funnel.
Page 24 37236 050305 SERVICE (cont.) SWEETNER SOLENOID V AL VE FIG. 16 SWEETNER SOLENOID V AL VE P3298 FIG. 17 SOLENOID V AL VE TERMINALS P2843 WHI/VIO to Brew Solenoid WHI/VIO to Brew Timer TL1 BRN/W.
Page 25 SERVICE (cont.) T ANK HEA TER FIG. 18 T ANK HEA TER Location: The tank heater is located inside the tank and se- cured to the tank lid. T est Procedures: 1.
Page 26 LIMIT THERMOSTAT BLU/BLK TANK HEATER "KEEP WARM" HEATER START L1 N BLK WHI BLK BREW TIMER WHI WHI GREEN WHI/YEL WHI/ORA BLK WHI/GRN WHI/VIO WHI BRN/WHI WHI/VIO WHI WHI SCHEMATIC WIRI.
Page 27 37236 050305 SCHEMA TIC WIRING DIAGRAM TB3QA LIMIT THERMO S TAT S W1 BREW TIMER BLK BLK BLK BLU/BLK RED RED RED WHI WHI WHI/VIO WHI/VIO WHI/GRN WHI/GRN WHI/ORN L1 L2 GRN/YEL WHI/YEL 37234.
デバイスBunn TB3Q-LPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bunn TB3Q-LPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBunn TB3Q-LPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bunn TB3Q-LPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bunn TB3Q-LPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bunn TB3Q-LPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBunn TB3Q-LPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bunn TB3Q-LPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBunn TB3Q-LPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。