1 Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .
2 Impor tant The manufacturer cannot be held responsible for injuries or losses caused by inc orrect use or installation of this product. Please note that the manufacturer reserves the right to invalidat e the guarantee supplied with this product following incorr ect installation or misuse of the appliance or use in a commercial en vironment.
3 Using your Extractor For best performance, y ou should switch on the extractor 15 minutes before starting to cook and leave it to run f or approximately 15 minutes after the end of cooking.
4 Care and Maintenanc e IMPORT ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWIT CHING OFF THE ELECTRICIT Y SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings.
5 Fig . 3 Care and Maintenanc e Changing the charcoal lter (r e -circulating only) When the display ashes alternating the speed selected with the letter F , the charcoal lters must be replac ed.
6 Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HOT . ALLOW IT TO C OOL BEFORE REMOVING IT . Using a at blade screwdriv er , carefully prise o the lamp cover as shown in gure 4. Remove the bulb and replac e with a 12V 20W halogen light bulb.
7 DOUBLE POLE SWITCHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electr icity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE.
8 Electrical I nformation Mains electrical voltage: 230 – 240V ac, 50Hz T otal rated power consumption: 330W T roubleshooting If your extractor is not working: 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown.
9 Mounting your Extractor IMPORT ANT : The extractor is intended to be mounted directly to the ceiling using xings appropriate for the ceiling . Ensure that there is adequat e ceiling strength and supports at the xing points; if in doubt, consult a joiner or electrician.
10 Installation Note: We r ecommend that you seek the help of another individual when installing this product. Preparing the extractor The electronic control bo x and ventilation pipe need to be tted to the motor body bef ore proceeding with the install.
11 Installation Assembling the extractor ready for mounting: 1. Place the extractor body on a table and x the support sec tions (D) using the supplied screws (E) as shown in g 11 below . 2. Remove the screws(A ) fastening the lower and upper(B) support sections as shown in g 12 below .
12 Installation Assembling the extractor ready for mounting: 4. Assemble the upper (B) and lower (C) support sections at the desired height (as calculated in step 3) using the supplied scr ews (G) as shown in g 13.
13 Installation Mounting the extractor to the ceiling: 1. Using the supplied template , drill four holes in the ceiling and t suitable wall plugs into the holes, if required . Note that plugs may not be required if the extractor is to be mounted directly to the ceiling joists.
14 Installation Mounting the extractor to the ceiling: 4. Recirculating mode: If the extractor is to be used as a recirculation device, ltering the air before recycling into the kitchen then the vent diverter needs to be tted. Fit the div erter(M) to the upper suppor t section using screw (I) and connect the ventilation pipe (H).
15 DOUBLE POLE SWITCHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electr icity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE.
16 NO TES:.
17 NO TES:.
18 NO TES:.
19 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CD A reserve the right to change specifications without prior notice. Attribute Symbol Value Units Model Identification evpk90 Annual Energy Consumption AEC Hood 134.
20 Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.cda.eu Passionate about style T o contact our Customer Car e Depar tment, or for Service, please contact us on the details below .
デバイスCDA EVPK90の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA EVPK90をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA EVPK90の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA EVPK90の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA EVPK90で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA EVPK90を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA EVPK90の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA EVPK90に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA EVPK90デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。