1 W415-0298 / K / 12.06.07 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER . Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalplaces.com • ask@continentalfire.
2 W415-0298 / K / 12.06.07 PG 3-4 INTRODUCTION W arranty General Instructions General Information Care of Glass Door , Catalytic T iles & Plated Parts 5-7 INST ALLA TION Combustion and V entilatio.
3 W415-0298 / K / 12.06.07 CONTINENTAL® gas fireplaces are manufactured under the strict Standard of the world recogn ized ISO 9001:2000 Qual ity Assurance Certificate. WOLF STEEL LTD. products are designed with superior components and materials , assembled by tr ained craftsmen who take great pride in their work.
4 W415-0298 / K / 12.06.07 Use only accessories designed for and listed with your specifi c fi replace. Early signs of carbon monoxide poisoning resem- ble the fl u, with headache, dizziness and/or nau- sea. If you have these signs, the heater may not be working properly .
5 W415-0298 / K / 12.06.07 ROOM 2 ROOM 1 This hea ter shall not be installed in a confined space or unusually tight constr uction unless pro visions are pr ovided for adequa te combustion and ventila tion air .
6 W415-0298 / K / 12.06.07 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi replace when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
7 W415-0298 / K / 12.06.07 T o install the fireplace face flush with the finished wall, position the framework to ac- commodate the thickness of the fi nished wall. Bend out the four nailing tabs, attached on either side of the fi replace and secure to the 2x4 framing.
8 W415-0298 / K / 12.06.07 The curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring. The hea ter must not be used when the hood is r e- mov ed. Hook the hood over the lip of the curtain support plate.
9 W415-0298 / K / 12.06.07 A C B FIGURE14 HOOD Attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. A CLIPS CENTRE SLOT FLANGE UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit.
10 W415-0298 / K / 12.06.07 FIGURE 22 FIGURE 20 Attach the connectors from the black and red wires to the blower . Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle. The wir e harness pr ovided in this kit is a univ ersal harness .
11 W415-0298 / K / 12.06.07 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. T urn off all electric power to the fi replace.
12 W415-0298 / K / 12.06.07 This pr ocedure m ust be performed by a qualified service per son! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fi bre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
13 W415-0298 / K / 12.06.07 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Co ntinental® d ealer or distributor. When ordering replacement parts always give the following information: 1.
14 W415-0298 / K / 12.06.07.
15 W415-0298 / K / 12.06.07 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
16 W415-0298 / K / 12.06.07 Flames are consist- ently too large or too small. Carbon- ing occurs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
17 W415-0298 / K / 12.06.07 W olf Steel Fir eplace Ser vice Histor y This fi replace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dea.
18 W415-0298 / K / 12.06.07 NO TES.
デバイスContinental CVF36Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Continental CVF36Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはContinental CVF36Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Continental CVF36Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Continental CVF36Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Continental CVF36Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はContinental CVF36Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Continental CVF36Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちContinental CVF36Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。