MODEL 2100R & 2200R Engine Gages Read Instructions Carefully ! !.
Saf ety Instructions This instrument was manuf actured and tested according to the applicable technical standards . It complies with all the safety regulations as shipped from the f actory . Installation and star tup must be performed by skilled personnel.
! ! T ABLE OF CONTENTS P age 1. Saf ety Instructions 2 2. Model Encodement 3 3. T echnical Specifications 3.1 Electrical 5 3.2 Mechanical 8 3.3 Environmental 9 4.
3 2. MODEL ENCODEMENT (f or 2100R/2200R series) 2111RXX-YYYY ZZ Model Numbers 2111 T emperature 2112 Fuel 2113 Pressure 2114 V oltage 2211 T emperature/Hour 2212 Fuel/Hour 2213 Pressure/Hour 2214 V ol.
4 R = case (round) XX = v oltage (DC v oltages only) YYYY = sequential number code describes gage’ s f actor y programming ZZ = ar twork code (OO = Cur tis) !.
5 3. TECHNICAL SPECIFICA TIONS 3.1 Electrical Operating V oltage Model Series 2100R and 2200R are availab le in either 12VDC or 24VDC (negative g round systems only) Operating V oltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.
Operating Current T otal system current is a function of the voltage, sender type, displa y mode, and the gage’ s factory programming. T ypical operating currents (not including the current to drive the sender) v ar y from 16-55 mA, f or 12V models , depending on model number .
Output signal trigger point (lower) First LED Second LED Output signal trigger point (upper) Ninth LED T enth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing m.
Damping and Hysteresis Tr ansducer po wer modulation (XPM) Used to reduce current in sender circuit Output signal f ormat Outputs are capable of sinking or sourcing up to 1mA, maximum (50 µ A maximum is standard) The 5V -0 output signal format is fully compatible with the Cur tis Model 1178 relay module.
Bezel Material Aluminum, blac k anodized Hardware U clamp (1) (Individually box ed 4 mm lock washers (2) un it s ) F emale 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) Hardware U clamp (1) (OEM bulk pac ked) 4 mm lock w ashers (2) 4 mm hex n uts (2) 3.
Vibration Meets SAE J 1378 March 83. Double amplitude of 1.53 mm with frequency sw eep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Wa ter/dust immunity F ace IP63 Rear IP50 Salt spra y (fog) ASTM B 117-73 as per SAE J1810, section 4.
4. INST ALLA TION Te r m inal Assignment f or Models 2111R, 2112R, 2113R 1 Sender in 2B attery + 3G round 4 Sender low (optional: for use with two wire senders) 5 Output signal (upper) 6 Output signal.
Te r minal Assignment f or Model 2114R 1 Not Connected ** 2B attery + 3G round 4 Not Connected** 5 Output signal (upper) 6 Output signal (lower) Te r minal Assignments f or Models 2211R, 2212R, 2213R .
Te r minal Assignments f or Model 2214R 1 Not connected*** 2B attery + 3G round 4 Hourmeter enable*** 5 Output signal (upper) 6 Output signal (lower) * Options terminal can be factory programmed to fu.
5. TR OUBLESHOO TING The follo wing checklist should help y ou to trou- b leshoot an y problems with the instrument. T urning the instrument off and then on again after about 10 seconds may solv e the prob lem in the simplest cases. Make sure to observe the saf ety instructions in Section 1.
6. MAINTENANCE Cur tis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the f actory within the warranty period will be replaced without charge.
Guarantee - These Curtis Instr uments’ products are guaran- teed against defects in w orkmanship and material for a period of three years , or as defined in the individual product literature, from date of shipment from our factory , when applied in a prop- er application within specified ratings.
CURTIS INSTRUMENTS, INC. 200 Kisco A venue, Mt. Kisco, NY 10549 T el. (914) 666-2971 • FAX (914) 666-2188 53018 REV A 10/97.
デバイスCurtis 2200Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Curtis 2200Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCurtis 2200Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Curtis 2200Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Curtis 2200Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Curtis 2200Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCurtis 2200Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Curtis 2200Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCurtis 2200Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。