Operating Instructions & Parts Manual 3VG81 Dayton Pr opane Construction Heater ® Form 5S3928 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
Dayton Operating Instructions and Parts Manual 3VG81 2 Dayton Pr opane Construction Heater ® General Safety Information IMPORT ANT : Make certain you r ead and understand all warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3 Model 3VG81 Carbon monoxide poisoning: Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 3VG81 4 Dayton Pr opane Construction Heater ® Air For Combustion And Heating Fuel Combustion Chamber DSI Ignitor Clean Heated Air Out (Front) Fan Solenoid V alve Nozzle Motor On/Off Switch Theory of Operation THE FUEL SYSTEM The hose/regulator assembly attaches to the propane gas supply .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 5 Model 3VG81 Installation (Continued) Hose Propane T ank Hose POL Fitting Supply V alve Inlet Connector Regulator Vent (pointing down) Figure 4 - Regulator With V ent Pointing Down IMPORT ANT : Extra hose or piping may be used if needed.
Dayton Operating Instructions and Parts Manual 3VG81 6 Dayton Pr opane Construction Heater ® Operation (Continued) Storage Disconnect heater from pr opane supply tank(s). 1. Store propane tank(s) in safe manner . See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFP A 58.
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 7 Model 3VG81 IGNITOR Make sure gap between ignitor electr ode and burner nozzle is .13 min./.15"max. Access ignitor electrode fr om inside combustion chamber . No other mainte- nance is needed for ignitor .
Dayton Operating Instructions and Parts Manual 3VG81 8 Dayton Pr opane Construction Heater ® Figure 9 - Repair Par ts Illustration For Repair Parts, call 1-800-323-0620 24 hours a day — 365 days a .
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 9 Model 3VG81 Repair Parts List 1 Upper Shell 098511-116 1 2 * #10-16 x 1/2" Screw M15823-27 8 3 Combustion Cham.
Dayton Operating Instructions and Parts Manual 3VG81 10 Dayton Pr opane Construction Heater ® 41 * #10-32 x 1/4" Screw M12461-25 2 42 * Hex TPG “F” 6-32 s 1/4" Screw M10908-1 2 43 Clip Nut M11271-8 8 44 High T emperature Wire Assembly 101480-10 1 45 High T emperature Wire Assembly 101480-11 1 47 DSI Control No.
デバイスDayton 3VG81の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dayton 3VG81をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDayton 3VG81の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dayton 3VG81の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dayton 3VG81で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dayton 3VG81を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDayton 3VG81の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dayton 3VG81に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDayton 3VG81デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。