Delkin DevicesメーカーEI - 25-1の使用説明書/サービス説明書
ページ先へ移動 of 44
INSTALLER: Please leave this manual with the appliance owner for futur e reference. NOT FOR USE WITH SOLID FUEL 200-0215 FEBRUARY 2005 EUR O 25 EUR O 25 - - 1 1 Vented Gas F ireplace Insert Heating Ap.
.
Congratulations on purchasing the Archgard Euro-25 Gas Fireplace Insert Heater! The Euro-25 is one of the most advanced gas he ating appliances on the market.
EUR O 25 -1 4 5.08: M odifications to NFPA-54, Ch apter 10 (2) Revise 10.8.3 by adding the following additional re quir ements: (a) For all side wall horizontally vented ga s fueled equipment installe.
T ABLE OF CONTENTS Caution & Safety Information 5 General Information 6 Appliance Description and Dimensions 7 Installation Instructions 8 Operation Instructions 20 Maintenance 22 Troubleshooting .
EUR O 25 -1 6 Due to high temperatures, the appliance should be located out of traffic and aw ay from furniture and draperies. Children and adults should be alerted to th e hazards of high surface temperature and stay away to avoid burns or clothing ignition.
EUR O 25 -1 7 GENERAL INFORMA TION This appliance is tested and certified to the follo wing U.S. and Canadian gas appliance standards. - ANSI Z 21.88b-2003 / CSA 2.33b-20 03, Vented Gas Fireplace Heater - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes.
EUR O 25 -1 8 APPLIANCE DESCRIPTION & DIMENSIONS GAS VALVE CONVECTION FAN SPEED CONTROL TOP LOUVERS BAY GLASS DOOR REMOVABLE CONTROL COVER SURROUND FRONT VIEW SPARKER APPLIANCE DIMENSIONS A B I K .
EUR O 25 -1 9 Leveling leg INST ALLA TION INSTRUCTIONS CLEARANCES TO COMBUSTIBLES Combustible mantle allo wed in shaded area. Mantle extension ma y be increased 1” (25 mm) for each ad ditional 1” (25 mm) increase in clearance height.
EUR O 25 -1 10 MINIMUM MASONRY FIREPLAC E DIMENSIONS 17” (432 mm) 25” (635 mm) 12” (305 mm) TOP VIEW The standard flue ad apter will fit if X is more than 5 ¾ ”.
EUR O 25 -1 11 INST ALLA TION INSTRUCTIONS - Continued Flue connector straight-up vent Flue connector offset vent Flue connector straight-up vent Flue connector offset vent MINIMUM ZERO-CLE ARANCE WOO.
EUR O 25 -1 12 PRECAUTIONS • This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes. • This appliance needs fresh air for safe operation a nd must be installed so there are provisions for adequate combustion and ventilati on air.
EUR O 25 -1 13 GAS CONNECTIONS Have your gas supplier or a qualified gas fitter run a gas supply line to the gas fireplace. The line must be properly sized and fitted according to the installati on codes. Up stream of the suppl y connection, the fitter shall provide an accessible manual shut-off valve.
EUR O 25 -1 14 ATTACHMENT OF FIREPLACE SURROUND The surround has four hooks that clip onto the si des of the appliance. Make sure the surround sits evenly with the front of the fireplace. Af ter the surround is properly installed, th e bottom edge of the centre sectio n of the surround is about ¾ ” from the top of the appliance.
EUR O 25 -1 15 GLASS DOOR WARNING: Glass door is fragile. Do not strike or a buse glass. Do not ope rate appliance with broken glass. Do not attempt to fix a broken glass door. It must be replaced with an identical one from the manufacturer. Do not attem pt to re move the glass door when the appliance is hot.
EUR O 25 -1 16 WARNING : Do not place the embers directly on the burner ports. A fire, explosion or excessive carbon monoxide (CO) may result, causing property damage, personal injury or loss of life. Do not add more or different materials to the burner than the amount and type supplied with the unit.
EUR O 25 -1 17 STEP 2 - Locate log #136 and place onto rear log suppor t using locator pins and pre-drilled holes in log. Log will sit as shown in the photo below. PINS FOR LOG # 136 STEP 3 - Locate log #137 and place onto the left side of the burner using locator pins and pre-drilled holes in log.
EUR O 25 -1 18 STEP 4 - Locate log #140 and place onto centre of burner using the locator pins and pre-drilled holes in log. Log should sit as shown in photo below. PIN HOLES FOR LOG # 140 STEP 5 - Locate log #141 and place onto right side of burner using the locator pins and pre-drilled holes in log.
EUR O 25 -1 19 STEP 6 - Locate log #135 and place onto rear log using the locator pins and pre-drilled holes in log. Log should sit as shown in photo below. PIN HOLE FOR LOG # 135 STEP 7 - Locate log #139 and place onto rear log using the locator pins and pre-drilled holes in log.
EUR O 25 -1 20 STEP 8 - Locate log #138 and place onto rear log using the locator pins and pre-drilled holes in log. Log should sit behind left grate tine as shown in photo below. FINAL LOG PLACEMENT - Please note that all logs should be placed exactly as shown.
EUR O 25 -1 21 OPERA TION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, pe rsonal injury or loss of lif e. This appliance has a pilot which must be lit by hand using the sparker located next to the appliance valve controls.
EUR O 25 -1 22 Set the thermostat, if present, to the lowest level. Set the flame adjustm ent knob to the HI position. Press slightly and tu rn the control knob clockwise 3 to the OFF position and wait 5 minutes; thus allowing any gases to escap e which may have accumulated in the combustion chamber.
EUR O 25 -1 23 MAINTENANCE CAUTION : Maintenance should only be c onducted on a cold appliance. The exterior painted surfaces, gl ass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable , mild, non-abrasive cleaner.
EUR O 25 -1 24 TROUBLESHOOTING SYMPTOM ACTION Pilot will not light after pressing the sparker m any times. 1. When lighting the appliance for the first time after installation or after servicing , th ere is air in the gas line. It takes a while for all the air to purge out of the pilot before gas can reach the pilot and ign ite.
EUR O 25 -1 25 TROUBLESHOOTING - Continued SYMPTOM ACTION The main burner does not turn on with the pilot lit. (continued ) 3. If using an optional t hermostat, check t o make sure t he therm ostat is set high enough to turn on the appliance. 4. If using an optional remote switch, check that the remote switch or the thermostat is turned on.
EUR O 25 -1 26 SER VICING Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer from which you have pur chased the .
EUR O 25 -1 27 REPLACEMENT OF FAN • Disconnect the power to the appliance. • Re move the louvers, control cover do or, brick panels, logs and burner. • Re move the firebox lower back. Remove the screws located at the back of the firebox. Take the lower firebox back out.
EUR O 25 -1 28 REPLACING MAJOR GAS COMPONENT S • Remove the glass door, log set and the burner. • Use a ½ ” wrench to loosen the orifice. • Change the orifice. • Attach the new orifice. • Replace the burner and the log set. • Test fire the appliance with the gl ass door off and check for gas leaks.
EUR O 25 -1 29 APPENDIX A EURO 25-1 - INSTRUCTIONS FOR INSTALLATION INTO VE NTED GAS FIREPLACES PRECAUTIONS • This installation must be conducted by a qualified gas applia nce installer and the installation must conform to the installation codes.
EUR O 25 -1 30 HOST GAS FIREPLACE PREPARATION • The following procedures must be conducted by a qualifie d gas appliance installer. • Double check the minimum firebox dimensions. • Disconnect electrical power and gas supply. • Remove the burner or sandpan, pilot, a nd all parts of the gas train assembly.
EUR O 25 -1 31 VENTING OF THE EURO- 25-1 IN SIDE THE HOST GAS FIREPLACE A connector kit (BCV4-KIT or BCV5-KIT ) is used to connect the EURO 25-1 insert to the host gas fireplace’s venting system. The connector slips into the host fireplace’s B-vent.
EUR O 25 -1 32 W ARNING : This fireplace has been modified for use with the Archgard EURO-25-1 gas insert. Usage without the EURO-25-1 gas insert may cause property damage, personal injury or loss of life. SAMPLE MODIFICA TION W ARNING PLA TE 303-0050 W ARNING : This fireplace has been modified for use with the Archgard EURO-25-1 gas insert.
EUR O 25 -1 33 INSTALLATION INSTRUCTIONS INSTALLING THE EURO 25-1 GAS FIREPL ACE INSERT HEATING APPLIANCE INTO VENTED ZERO-CLEARANCE GAS FIREPLACE: CANADIAN HEATING PRODUCT MODEL MONTIGO 28 SERIES 1. Remove the louvers and screens or glass door. 2. Remove the burner/sandpan assembly, valve and pilot assem bly from the firebox bottom plate.
EUR O 25 -1 34 1. Unhook the screen rod at the center and remove screens or glass door. 2. Unscrew and remove the front trim st rip at the front of the firebox bottom. 3. Remove the burner/sandpan assembly, valve and pilot assem bly from the firebox bottom plate.
EUR O 25 -1 35 1. Remove the screens and rod or glass door. 2. Remove the bottom door track. 3. Remove the pilot and valve assembly. 4. Cut the front legs of sandpan with an ab rasive cutting disc or plasma cutter. Bend up sandpan to expose rear legs.
EUR O 25 -1 36 1. Remove the louvers and screens or glass door. 2. Remove the burner/sandpan assembly, valve and pilot assem bly from the firebox bottom plate. Flip the plate over and leave the plate in place to suppo rt the gas insert. 3. Remove the facing cross members with an abrasive cutting disc or plasma cutter.
EUR O 25 -1 37 1. Remove the screens or glass door. 2. Remove the burner assembly. (two 5/16” Hex screws at the back) 3. Remove the brick panels. 4. Remove the front top deflector. (f our 5/16” Hex scre ws at the top) 5. Remove the valve tray. (two Philips s crews on the sides) 6.
EUR O 25 -1 38 IMPOR T ANT INFORMA TION * Please have the installer fill out the installa tion information for warranty and future reference. NAME ADDRESS CITY STATE / PROV COUNTRY ZIP / POS TAL CODE .
This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an Ar chgard gas burning fireplace (s) th at the product will be free of defe cts in materials and workmansh ip under normal use and service, for a “lifetim e”.
EUR O 25 -1 40 Parts can be ordered through your lo cal dealer or distributor by giving ITEM # and DESCRIPTION. REPLACEMENT P A R TS FOR EURO 25-1 ITEM # DESCRIPTION QTY.
EUR O 25 -1 41 NOTES.
POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSE D CUT ALONG LINE CUT ALONG LINE CUT ALONG LINE Model # : EURO 25 -1 Serial #: Date Installed: / / Name: Address: City: State/Prov: ZIP: Pho.
.
Ar c hgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com.
デバイスDelkin Devices EI - 25-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delkin Devices EI - 25-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelkin Devices EI - 25-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delkin Devices EI - 25-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delkin Devices EI - 25-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delkin Devices EI - 25-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelkin Devices EI - 25-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delkin Devices EI - 25-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelkin Devices EI - 25-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。