For more information, visit www .desatech.com DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL NA TURAL GAS “TUDOR” MODEL (V)T32EN SERIES PROP ANE/LP GAS “TUDOR” MODEL (V.
www .desatech.com 1 1 1987-01D 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Product Identication ...............
www .desatech.com 1 1 1987-01D 3 SAFETY INFORMA TION Continued This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 1 1987-01D 4 SAFETY INFORMA TION Continued 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 1 1987-01D 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • The blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the replace when framing.
www .desatech.com 1 1 1987-01D 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 4 - Framing Clearances for Installation Against an Exterior Wall Figure 5 - Framing Clearances for Corner Installation C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 Wall Ref.
www .desatech.com 1 1 1987-01D 7 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N .
www .desatech.com 1 1 1987-01D 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 1 1987-01D 9 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 1 1987-01D 10 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 1 1987-01D 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Scr.
www .desatech.com 1 1 1987-01D 12 CORN ER AND AL TERNA TE INST ALL A TIO N Recommended Applications: • Corner ground oor installation • G ro un d o or in st a l la ti on w he re pi p e v en.
www .desatech.com 1 1 1987-01D 13 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 1 1987-01D 14 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 1 1987-01D 15 Figure 20 - Installing Firestop If area above is a living space, install restop below framed hole. If area above is an attic or insulated area, install restop above framed hole. 7. T wist-lock the vent cap onto the last section of vent pipe.
www .desatech.com 1 1 1987-01D 16 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 1 1987-01D 17 AND COMPONENTS P47-6 6".
www .desatech.com 1 1 1987-01D 18 FIREPLACE INST ALLA TION Use proper gas type for replace unit you are installing.
www .desatech.com 1 1 1987-01D 19 FIREPLACE INST ALLA TION Continued Figure 28 - Location of Wiring Diagram Decal (Model May V ary from Illustration) Wiring Diagram Decal 12" in Front of Burner 9. Check to make sure power cord is completely clear of blower wheel and there are no other foreign objects in blower wheel.
www .desatech.com 1 1 1987-01D 20 1 1. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom ap - proxima tely 12" in front of blower (see Figure 28, page 19).
www .desatech.com 1 1 1987-01D 21 FIREPLACE INST ALLA TION Continued Figure 32 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 1 1987-01D 22 PRESSURE TESTING GAS SUPPL Y PIPING SYSTEM T est Pressures In Excess Of 1/2 PSIG 1. Dis conne ct rep lac e and i ts indiv idual equ ip - ment shutoff valve from gas supply piping sy st em .
www .desatech.com 1 1 1987-01D 23 REMOVING/REPLACING GLASS DOOR .
www .desatech.com 1 1 1987-01D 24 .
www .desatech.com 1 1 1987-01D 25 4. Place log #4 (right log) onto pin on right side of front log as shown in Figure 44. 5. Pl ace lo g #5 (base log) onto front left part of grate making sure notches t over prongs of grate. See Figure 45. 6. Place log #6 (left log) onto two pins on left side of back and front log.
www .desatech.com 1 1 1987-01D 26 FIREPLACE INST ALLA TION Continued Ember Material Figure 46 - Placing Ember Material on Burner 8. Pull ember material apart into pieces no larg er than a dime.
www .desatech.com 1 1 1987-01D 27 STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH IGN EV2 INCOMING MAIN GAS SUPPL Y EV1 GAS LINE TO BURNER 24V AC 120V AC INCOMING 120V AC (FUSE BOX OR BREAKER) OFF ON WALL SWITCH (NOT SUPPLIED) GREEN BLACK WHITE 120v , 60Hz, 0.
www .desatech.com 1 1 1987-01D 28 5. T u rn eq ui pme nt shu to ff val ve clo ck wis e to the OFF position (see Figure 49). Do not force. 6. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor .
www .desatech.com 1 1 1987-01D 29 OPERA TING FIREPLACE Continued TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Open lower louver panel. 4. T u rn eq ui pme nt shu to ff val ve clo ck wis e to OFF .
www .desatech.com 1 1 1987-01D 30 CLEANING AND MAINTENANCE .
www .desatech.com 1 1 1987-01D 31 TROUBLESHOO TING .
www .desatech.com 1 1 1987-01D 32 Pilot will not stay lit No gas to burner, although wall switch and valve are set to the ON position Frequent pilot ou.
www .desatech.com 1 1 1987-01D 33 Glass soots Remote does not function Dark residue on logs or inside of replace 1. Flame impingement on logs 2 . Debris around burner air mixer 1.
www .desatech.com 1 1 1987-01D 34 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1987-01D 35 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1987-01D 36 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1987-01D 37 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1987-01D 38 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 1 1987-01D 39 ACCESSORIES NOTICE: All accessories may Pu rch ase th ese rep lace acce ss or ies from your loca l reta iler .
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1987-01 Rev . D 03/06 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
デバイスDesa (V)T32EN SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa (V)T32EN SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa (V)T32EN SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa (V)T32EN SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa (V)T32EN SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa (V)T32EN SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa (V)T32EN SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa (V)T32EN SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa (V)T32EN SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。