DesaメーカーROPANE CONSTRUCTION HEATERSの使用説明書/サービス説明書
ページ先へ移動 of 16
! GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC- TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
2 099162 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ...........................................
3 099162 SAFETY INFORMA TION Continued ! W ARNINGS Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.
4 099162 PRODUCT IDENTIFICA TION Generic LP 155 LP-PFA/PV 008B Hot Air Outlet (Front) Handle Fan Guard Upper Shell On/Off Switch Power Cord Hose /Regulator Assembly Inlet Connector Figure 2 - 150,000 .
5 099162 45/80 LP SIDE LP-PFA/OV 001A Air For Combustion And Heating Fuel Combustion Chamber DSI Nozzle Figure 3 - Cross Section Operational View (80,000 BTU/Hr Model Shown) Clean Heated Air Out (Front) Cool Air In (Back) THEOR Y OF OPERA TION The Fuel System: The hose/regulator assembly attaches to the propane gas supply.
6 099162 PROP ANE SUPPL Y Propane gas and propane tank(s) are to be furnished by the user. Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/ NFPA 58 .
7 099162 Generic LP 45 & 80 LP-PFA/P 023 3. Connect hose to inlet connector. Tighten firmly using a wrench. IMPORTANT: Extra hose or piping may be used if needed. Install extra hose or piping between hose/regulator assembly and propane tank. You must use the regulator supplied with heater.
8 099162 To Start Heater 1. Follow all installation, ventilation and safety information. 2. Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater. 3. Plug power cord of heater into a three-prong, grounded extension cord.
9 099162 MAINTENANCE ! W ARNING Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur. 1. Keep heater clean. Clean heater annually or as needed to remove dust and debris.
10 099162 LP-PFA/P 019B 45/80 Models FAN CROSS SECTION LP-PFA/P 013 FAN LP-PFA/P 023 SERVICE PROCEDURES Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2.
11 099162 LP-PFA/P 019A 150 Model Air Sensing Switch (80,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Clean air sensing switch paddle. Use soft cloth moistened with kerosene or solvent. IMPORTANT: Do not scrub. Use gentle cleaning action.
12 099162 7. Replace spark plug into combustion chamber. Tighten spark plug mount- ing nut finger tight onto spark plug threads. Use 11/16" socket to hold spark plug mounting nut. Tighten spark plug to spark plug mounting nut using 13/16" spark plug socket.
13 099162 WIRING DIAGRAMS 80,000 BTU/Hr Model Electrical Connection Diagram Motor Air Switch Black Black Black Black Green/Yellow Flame Sensor Spark Plug Terminal Board Green/Yellow Ignition Cable Dir.
14 099162 WIRING DIAGRAMS 150,000 BTU/Hr Model Electrical Connection Diagram Power Cord 120 VAC Motor Green Solenoid Valve L or 1 M or 3 S or 2 Red On/Off Switch Safety Control G V VR ACR AC Black Bla.
15 099162 ACCESSORIES Purchase accessories and parts from your nearest dealer or service center. If your dealer or service center can not supply an accessory or part, either contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or call DESA International’s Parts Depart- ment at (502) 781-9600.
DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for six (6) months from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.
デバイスDesa ROPANE CONSTRUCTION HEATERSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa ROPANE CONSTRUCTION HEATERSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa ROPANE CONSTRUCTION HEATERSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa ROPANE CONSTRUCTION HEATERSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa ROPANE CONSTRUCTION HEATERSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa ROPANE CONSTRUCTION HEATERSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa ROPANE CONSTRUCTION HEATERSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa ROPANE CONSTRUCTION HEATERSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa ROPANE CONSTRUCTION HEATERSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。