Save this manual for future reference. ® YELLO W FLAME DESIGN UNVENTED (VENT -FREE) PR OP ANE/LP GAS LOG HEA TER (Manually-Controlled Models Also Designed Certified as Vented Decorative Appliance) This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
2 102991 CONTENTS SECTION PAGE SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS IMPORTANT: Read this owner ’ s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
3 102991 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 102991 PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Gas Log Heater LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
5 102991 AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
6 102991 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
7 102991 AIR FOR COMBUSTION AND VENTILA TION Continued WARNING ICON G 001 W ARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
8 102991 INST ALLING NOTICE A qualified service person must install heater. Follow all local codes. W ARNING Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.
9 102991 INST ALLING Continued Continued INSTALLATION AND CLEARANCES (Vent-Free Operation Only) W ARNING Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining wall. Carefully follow the instructions below.
10 102991 Heat Resistant Material (A) INST ALLING Continued NOTICE You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fire- place opening is not needed.
11 102991 INST ALLING Continued Minimum Non Combustible Material Clearances If Using Mantel You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick.
12 102991 14" Min. Combustible Material Non-Combustible Material Hearth 5" Min. Combustible Material INST ALLING Continued Floor Clearances A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
13 102991 INST ALLING Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of non combustible material.
14 102991 INST ALLING Continued INSTALLING HEATER BASE ASSEMBLY WARNING ICON G 001 W ARNING If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against soot- ing.
15 102991 INST ALLING Continued CONNECTING TO GAS SUPPLY NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. WARNING ICON G 001 CAUTION Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied).
16 102991 INST ALLING Continued The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur.
17 102991 WARNING ICON G 001 CAUTION Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings. Figure 14 - Gas Connection * Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
18 102991 ON POSITION OFF POSITION 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
19 102991 INST ALLING Continued W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS Each log is marked with a number.
20 102991 OPERA TING HEA TER Manually- Controlled Models 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Press in and turn control knob clockwise Clockwise to the OFF position. Figure 21 - Control Knob and Ignitor Button Location 4.
21 102991 OPERA TING HEA TER Manually- Controlled Models Continued T O TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and turn control knob clockwise Clockwise to the HIGH position. 2. Turn control knob clockwise Clockwise to the pilot position.
22 102991 MANUAL LIGHTING PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, pages 20 and 21. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
23 102991 Figure 23 - Control Knob and Ignitor Button Location 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
24 102991 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
25 102991 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use.
26 102991 TROUBLE- SHOOTING Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3 . Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5.
27 102991 TROUBLE- SHOOTING Continued OBSERVED PROBLEM Burner does light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensa- tion noticed on windows Heater produces a whistling noise when burner is lit REMEDY 1.
28 102991 TROUBLE- SHOOTING Continued W ARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
29 102991 OPTIONAL POSITIONING OF THERMOST A T SENSING BULB For Masonry and Factory-built Metal Fireplace If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.
30 102991 OPTIONAL POSITIONING OF THERMOST A T SENSING BULB For Masonry and Factory-built Metal Fireplace Continued Adhesive-backed Mounting Clip Figure 30 - Locating Thermostat Sensing Bulb on Masonry Fireplace Thermostat Sensing Bulb If you hav e a factory-b uilt metal f ireplace, see Figure 31 for location.
31 102991 TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
32 102991 Note: Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty. Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replace- ment part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
33 102991 ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-472-7879 for referral information. You can also write to the address listed on the back page of this manual.
34 102991 ILLUSTRA TED P ARTS BREAKDOWN V ariable Manually- Controlled Models 5 3 2 1 4 22 11 12 13 21 8 22 22 6 7 10 9 16 15 17 19 23 18 14 19 24 20-2 20-1 20 18 25 CGD3018P CGD3924P CGD3930P.
35 102991 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual. P ARTS LIST KEY CGD3018P CGD3924P CGD3930P NO. PART NUMBER PART NUMBER PART NUMBER DESCRIPTION QTY.
36 102991 ILLUSTRA TED P ARTS BREAKDOWN Thermostatically- Controlled Manuals CGD3924PT 5 22 22 22 3 2 1 4 21 8 6 7 11 12 13 9 10 17 19 19 24 20-2 20-1 20 18 23 25 16 22 15 14.
37 102991 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.
38 102991 NOTES ________________________________________________________________ ________________________________________________________________ ______________________________________________________.
39 102991 NOTES ________________________________________________________________ ________________________________________________________________ ______________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
デバイスDesa Tech CGD3018Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa Tech CGD3018Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa Tech CGD3018Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa Tech CGD3018Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa Tech CGD3018Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa Tech CGD3018Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa Tech CGD3018Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa Tech CGD3018Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa Tech CGD3018Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。