INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS BF-10-2 BF-20-2 BF-30-2 W ARNING: If not installed, operated and ma in ta in ed in acc or da nc e with the man uf ac tu r - er's instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness.
16943-7-0907 Page 2 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas .............................
16943-7-0907 Page 3 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.
16943-7-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can af fect your sensitivity or ability to detect that odor .
16943-7-0907 Page 5 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip - ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency .
16943-7-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 Btu (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16943-7-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
16943-7-0907 Page 8 SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 5. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line.
16943-7-0907 Page 9 On Sheet Rock W all 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. T ighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors.
16943-7-0907 Page 10 T O TURN OFF GAS T O APPLIANCE 1. STOP! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. T urn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF".
16943-7-0907 Page 1 1 Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot. T o light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.
16943-7-0907 Page 12 The correct flame will be blue and will extend beyond the thermo- couple. The flame will surround the thermocouple just below the tip.
16943-7-0907 Page 13 Glass Removal, Cleaning and Glass Replacement 1. Remove chrome grill from reflector . 2. Slide glass upward to remove glass from chrome grill. 3. Clean glass with a non-abrasive household glass cleaner and warm water . Gas fireplace glass cleaner can also be used.
16943-7-0907 Page 14 1. Spark electrode does not pr oduce spark. a. Spark electrode broken - replace. b. Ignitor wire ma y not be attache d to spa rk elect rode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode pr oduces spark but pilot does not light.
16943-7-0907 Page 15 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS.
16943-7-0907 Page 16 P AR TS VIEW.
16943-7-0907 Page 17 INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower .
16943-7-0907 Page 18 P ARTS LIST Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri- cal Code, ANSI/NFP A 70, if an external electrical source is utilized.
16943-7-0907 Page 19 SER VICE NOTES.
16943-7-0907 Page 20 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
デバイスEmpire Comfort Systems BF-30-2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems BF-30-2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems BF-30-2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems BF-30-2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems BF-30-2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems BF-30-2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems BF-30-2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems BF-30-2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems BF-30-2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。