Empire Comfort SystemsメーカーDV33IN33Lの使用説明書/サービス説明書
ページ先へ移動 of 28
Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL INNSBROOK FIREPLACE INSERT DIRECT VENT GAS FIREPLACE HEA TER MODEL SERIES DV25IN33L(N,P)-1 DV33IN33L(N,P)-1 DV35IN33L(N,P)-1 UL FILE NO.
23015-3-0707 Page 2 T ABLE OF CONTENTS Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas ............................................
23015-3-0707 Page 3 DO NOT OPERA TE THIS APPLIANCE WITHOUT GLASS FRONT P ANEL INST ALLED Before enclosing the vent pipe assembly , operate the appliance to ensure it is venting pr operly . • Children and adults should be alerted to the hazards of high surface temperatur es and should stay away to avoid burns or clothing ignition.
23015-3-0707 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
23015-3-0707 Page 5 W arning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS. Improper installation or use of the fireplace can cause serious injury or death from fir e, burns, explosions, or carbon monoxide poisoning. Instructions to Installer 1.
23015-3-0707 Page 6 SPECIFICA TIONS DV25IN33L MODELS LP Nat Input Btu/hr Maximum 25,000 25,000 Btu/hr Minimum 17,000 17,000 KWH (Maximum) 7.30 7.30 (Minimum) 5.00 5.00 Orifice #53 (0.0596) #42 (0.0935) Air Shutter Opening Full Open 1/8” DV33IN33L MODELS LP Nat Input Btu/hr Maximum 33,000 33,000 Btu/hr Minimum 25,000 25,000 KWH (Maximum) 9.
23015-3-0707 Page 7 FIREPLACE INSER T DIMENSIONS Figure 1 When planning a fireplace insert installation, it’ s necessary to determine: • The vent system configuration to be used. • Gas supply piping. • Whether optional accessories - devices such as a wall switch or remote control - are desired.
23015-3-0707 Page 8 MANTLE AND TRIM CLEARANCES COMBUSTIBLE MANTEL/TRIM AREA 12” 10” 1 3/4” 23” 1 1 ” Combustible Material No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles.
23015-3-0707 Page 9 Figure 5 The gas pipeline can be brought in through the right or left side of the appliance. The insert has a Flexline with shutoff valve located on the right side when facing the unit. See Figures 5 and 6. Consult the current National Fuel Gas Code, AN SI Z223.
23015-3-0707 Page 10 VENTING AND INST ALLA TION 1. Before beginning, remove glass door and log package from unit. Also check to make sure there is no hidden damage to the unit.
23015-3-0707 Page 1 1 VENTING AND INST ALLA TION V ent System Appr ovals Figure 8 shows the vent termination caps and systems approved for use with these models.
23015-3-0707 Page 12 Figure 8 VENTING AND INST ALLA TION RECT ANGULAR TERMINA TION CAP (DVVK3FV KIT) VENT CLAMPS INT AKE VENT FLUE EXHAUST VENT OPTIONAL ON/OFF SWITCH LOCA TION 10’ MINIMUM 35’ MAXIMUM VENT CLAMPS NOTE: LONG EXTENSION TUBE FOR INLET VENT CONNECTION.
23015-3-0707 Page 13 V ertical Through the Roof Applications The Gas Fireplace Insert has been approved for: a) V ertical installations up to 35 feet in height (top of insert to cap). b) T wo sets of 45 degree elbow of fsets (bends in flexvent) within the vertical installation.
23015-3-0707 Page 14 AL TERNA TE ON/OFF SWITCH INST ALLA TION WIRING THE FIREPLACE Note: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENT AL FIREPLACE OPERATION.
23015-3-0707 Page 15 SURROUND P ANEL INST ALLA TION INST ALLING THE TRIM SURROUNDS Combustible materials MUST NEVER overlap onto the front face. W ARNING: WHEN FINISHING THE FIREPLACE INSER T , NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET LOUVERS ON THE FIREPLACE IN - SER T IN ANY MANNER.
23015-3-0707 Page 16 BLOWER ACCESSOR Y INFORMA TION The appliance, when installed must be electrically connected and grounded in accordance with local codes or , in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFP A No.
23015-3-0707 Page 17 LOG PLACEMENT BACK LOG LEFT TWIG RIGHT TWIG RIGH T CENTER LOG RIGHT FRONT LOG LEFT FRONT LOG LEFT CENTER LOG Figure 18 Figure 19 Note: Center the front two logs on the front log support ledge. Then make sure they are positioned all the way forward and touching the back edges of the grate tang uprights.
23015-3-0707 Page 18 OPERA TING INSTRUCTIONS Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to pur ge themselves of this air .
23015-3-0707 Page 19 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF . 3. T urn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly . 5. Push in gas control knob slightly and turn clockwise to "OFF .
23015-3-0707 Page 20 ST ANDING PILOT WIRING ST ANDING PILOT WIRING DIAGRAM For Standing Pilot Ignition Wiring Appliance Requirements W ARNING: DO NOT CONNECT 1 10-120 V AC TO THE GAS CONTROL V AL VE OR THE APPLIANCE WILL MALFUNCTION AND THE V AL VE WILL BE DE - STROYED.
23015-3-0707 Page 21 With proper installation and maintenance, your new Direct V ent Gas Fireplace will provide years of trouble-fr ee service. If you do experience a pr oblem, r efer to the T rouble Shooting Guide below . This guide will assist a qualified service person in the diagnosis of problems and the corr ective action to be taken.
23015-3-0707 Page 22 INSER T MAINTENANCE AND SER VICE Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance checkup at the beginning of each heating season.
23015-3-0707 Page 23 Decorative Mission Louver Decorative Leaf Louver Decorative Arch Louver STD Louvers 45 Deg STD Contemporary Surround Cast Iron T raditional Surround Bottom Cover DECORA TIVE ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer .
23015-3-0707 Page 24 INSER T P AR TS VIEW.
23015-3-0707 Page 25 INSER T P AR TS LIST P AR T NUMBER INDEX NO. DV25IN33L(N,P) DV33IN33L(N,P) DV35IN33L(N,P) DESCRIPTION 1 22950 22950 22950 GUIDE, FLUE CONNECTOR 2 23309 23211 23211 VENT SLIDE PLA .
23015-3-0707 Page 26 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number .
23015-3-0707 Page 27 SER VICE NOTES.
23015-3-0707 Page 28 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
デバイスEmpire Comfort Systems DV33IN33Lの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems DV33IN33Lをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems DV33IN33Lの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems DV33IN33Lの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems DV33IN33Lで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems DV33IN33Lを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems DV33IN33Lの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems DV33IN33Lに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems DV33IN33Lデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。