Empire Comfort SystemsメーカーRH-65C-1の使用説明書/サービス説明書
ページ先へ移動 of 18
12822-2-0903 Page 1 WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr op- erty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2 12822-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas .............................
12822-2-0903 Page 3 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
Page 4 12822-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor.
12822-2-0903 Page 5 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation.
Page 6 12822-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.
12822-2-0903 Page 7 CLEARANCES Clearances: When facing the front of the room heater the minimum clearances to combustible construction (material) are the following: Left side 6 inches (152mm). Right side 6 inches (152mm). Recommend 18 inches ((457mm) on left side for servicing.
Page 8 12822-2-0903 VENT SAFETY SHUT OFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system.
12822-2-0903 Page 9 1. STOP! Read the safety information above on this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”.
Page 10 12822-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet.
12822-2-0903 Page 11 Cleaning Pilot Burner After use, cleaning of the pilot burner may be required for the proper flame. The pilot orifice can be cleaned with high pressure air or by placing under running water. Pilot orifice must be dry before replacement.
Page 12 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 23 11713 Pilot Tubing (RH-65-6) 24 RH-457 Air Shutter Bracket 25 P-267 Manifold Assembly (RH-50-6) 25 P-268 Manifold Assembly (RH-65-6) 26 P86-3.
12822-2-0903 Page 13 P AR TS VIEW RH-50 & RH-65.
Page 14 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 18 R-6126 Electrode and Wire Assembly 19 11712 Pilot Tubing (RH-50C-1) 19 11713 Pilot Tubing (RH-65C-1) 20 RH-457 Air Shutter Bracket 21 P-267 Manifold Assembly (RH-50C/CB-1) 21 P-268 Manifold Assembly (RH-65C-1) 22 P86-3.
12822-2-0903 Page 15 P AR TS VIEW RH-50C & RH-65C.
Page 16 12822-2-0903 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward.
12822-2-0903 Page 17 Attention : Wiring harness on blower is factory assembled and installed. If wiring harness becomes disassembled use the following steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly.
Page 18 12822-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeb urg A v e. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: inf o@empirecomf ort.com WEB SITE: www .
デバイスEmpire Comfort Systems RH-65C-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems RH-65C-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems RH-65C-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems RH-65C-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems RH-65C-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems RH-65C-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems RH-65C-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems RH-65C-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems RH-65C-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。