INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 W ARNING: If not installed, operated and main- tained in acco rdance wit h the manu facturer’s instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness.
16941-5-0907 Page 2 SECTION P AGE Important Safety Information ..................................................................................... 3 Safety Information for Users of LP Gas .............................................................
16941-5-0907 Page 3 • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of mor e than 10,000 Btu per hou r sha ll not be inst alled in a bed room or bathr oom.
16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
16941-5-0907 Page 5 *Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFP A54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.
16941-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’ s (.3KW’ s) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
16941-5-0907 Page 8 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
16941-5-0907 Page 9 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws).
16941-5-0907 Page 1 1 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver , be sure the bottom lip of upper louver goes behind the heat shield.
16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
16941-5-0907 Page 13 SR-10T , SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques.
16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther - mocouple. The flame will surround the thermocouple just below the tip.
16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Att ent ion: The ther moc oupl e CAN NOT be repl aced as an in divi dual item. Y ou must order a new pilot when replacing thermocouple. 1. T urn OFF gas supply to the heater . 2.
16941-5-0907 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBL Y - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO .
16941-5-0907 Page 17 INDEX P AR T NUMBER NUMBER DESCRIPTION SR-18T INDEX P AR T NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBL Y - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASI.
16941-5-0907 Page 18 SR-10T P AR TS VIEW.
16941-5-0907 Page 19 SR-18T P AR TS VIEW.
16941-5-0907 Page 20 SR-30T P AR TS VIEW.
16941-5-0907 Page 21 REFLECTOR A ND LOUVERS ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W F AN CONTROL HEA T SHIELD CORD SET HOLE IN CASING BAC K INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is inst alled onto the wall, in order to install the optiona l blower , the heater must be removed from the wall.
16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized .
16941-5-0907 Page 23 SER VICE NOTES.
16941-5-0907 Page 24 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
デバイスEmpire Comfort Systems SR-10T-3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems SR-10T-3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems SR-10T-3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems SR-10T-3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems SR-10T-3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems SR-10T-3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems SR-10T-3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems SR-10T-3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems SR-10T-3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。