Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-6-3 SR-10-3 SR-18-3 SR-30-3 SR-30 SHOWN This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not pr ohibited by local codes.
16942-5-0907 Page 2 Important Safety Information ............................................................................... 3 Safety Information for Users of LP Gas ............................................................... 4 Introduction ..
16942-5-0907 Page 3 • An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,00 0 Btu pe r ho ur sh all no t be ins talle d in a be dro om or bathr oom.
16942-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
16942-5-0907 Page 5 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with unvented room heater . 3. Installer should show owner how to start and operate unvented room heater .
16942-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16942-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
16942-5-0907 Page 8 Figure 3 (SR-6) When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches 152mm). Do not install in alcove or closet. Rear wall 0 (0mm) inches.
16942-5-0907 Page 9 Figure 5 (SR-10) CEILING WINDOW SILL OR SHELF 24” MIN (610mm) 14” MIN (356mm) 12” MAX (305mm) 0” (0mm) CLEARANCE TO REAR W ALL SIDE VIEW 2” MIN (51mm) FLOOR Figure 6 (SR-.
16942-5-0907 Page 10 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
16942-5-0907 Page 1 1 On Solid W all 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall. 2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall.
16942-5-0907 Page 12 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 14. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line. *Floor stand can not be used in a bathroom or bedroom installation.
16942-5-0907 Page 13 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
16942-5-0907 Page 14 SR-6 Main Burner Flame (Figur e 15) The main burner flame will have a red-orange glow over the sur- face of the ceramic plaque. The red-orange glow on the surface of the ceramic plaque will have a pattern in the shape of a number 1.
16942-5-0907 Page 15 The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip.
16942-5-0907 Page 16 1. Spark electrode does not produce spark. a. Spark electrode broken - replace. b. Ignitor wire may not be attached to spark electrode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode produces spark but pilot does not light.
16942-5-0907 Page 17 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor .
16942-5-0907 Page 18 USE ONL Y MANUF ACTURER’S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. SR-18 INDEX NUMBER P ART NUMBER DESCRIPTION 1 13346 CASING SIDE ASSEMBL Y .
16942-5-0907 Page 19 SR-6 P AR TS VIEW.
16942-5-0907 Page 20 SR-10 P AR TS VIEW.
16942-5-0907 Page 21 SR-18 P AR TS VIEW.
16942-5-0907 Page 22 SR-30 P AR TS VIEW.
16942-5-0907 Page 23 INST ALLING OPTIONAL BLOWER SRB-18 OR SRB-30 If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on op - tional floor stand there is adequate access area available to install the optional blower .
16942-5-0907 Page 24 Wiring The appliance, when installed , must be electr ically grounde d in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized.
デバイスEmpire Comfort Systems SR-30の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems SR-30をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems SR-30の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems SR-30の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems SR-30で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems SR-30を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems SR-30の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems SR-30に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems SR-30デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。