16009-1-0504 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 EFFECTIVE DA TE MA Y 2004 This is an unvented gas-fired heater . It uses air (oxygen) from the r oom in which it is installed.
Page 2 16009-1-0504 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas .............................
16009-1-0504 Page 3 • Installation and repair should be done by a QUALIFIED SERVICE PERSON. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc.
Page 4 16009-1-0504 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor.
16009-1-0504 Page 5 Model SR-10T SR-18T SR-30T Input BTU/HR (KW/H) Five Plaques — — 30,000 (8.8) BTU/HR (KW/H) Three Plaques — 18,000 (5.3) — BTU/HR (KW/H) One Plaque 10,000 (2.
Page 6 16009-1-0504 WA TER VAPOR: A BY -PRODUCT OF UNVENTED ROOM HEA TERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.
16009-1-0504 Page 7 GAS SUPPL Y The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
Page 8 16009-1-0504 SR-10T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
16009-1-0504 Page 9 SR-18T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm).
Page 10 16009-1-0504 WALL MOUNT INST ALLA TION Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2.
16009-1-0504 Page 11 OPTIONAL FLOOR ST AND INST ALLA TION 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield.
Page 12 16009-1-0504 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
16009-1-0504 Page 13 MAIN BURNER FLAME CHARACTERISTICS SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques.
Page 14 16009-1-0504 PILOT FLAME CHARACTERISTICS The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.
16009-1-0504 Page 15 APPLIANCE MAINTENANCE Removing Pilot/Thermocouple From Main Burner Assembly Attention: The thermocouple CAN NOT be replaced as an individual item. You must order a new pilot when replacing thermocouple. 1. Turn OFF gas supply to the heater.
Page 16 16009-1-0504 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBLY - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO I.
16009-1-0504 Page 17 INDEX PART NUMBER NUMBER DESCRIPTION SR-18T INDEX PART NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBLY - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SI.
Page 18 16009-1-0504 SR-10T P AR TS VIEW.
16009-1-0504 Page 19 SR-18T P AR TS VIEW.
Page 20 16009-1-0504 SR-30T P AR TS VIEW.
16009-1-0504 Page 21 INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on optional floor stand there is adequate access area available to install the optional blower.
Page 22 16009-1-0504 .. . . If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 125 ° C wire or its equivalent.
16009-1-0504 Page 23 SER VICE NOTES.
Page 24 16009-1-0504 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 PH: 1-800-851-3153 F AX: 1-800-443-8648 E-MAIL: info@empirecomfort.
デバイスEmpire Products SR-30T-3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Products SR-30T-3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Products SR-30T-3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Products SR-30T-3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Products SR-30T-3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Products SR-30T-3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Products SR-30T-3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Products SR-30T-3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Products SR-30T-3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。