SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 28 Direct Vent By SHERWOOD INDUSTRIES OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
2 SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person.
TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Planning your installation 6 Installation of Log Sets and Embers 14 Operating Instructions 15 Maintenance.
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 22"/ 56 cm Rear Width: 22"/ 56 cm Height: 27-1/2"/ 70 cm* Depth 19"/ 48 cm (*not including vent coupling) Shipping Weight: 210 lbs/95 kg CLEARANCES: A. Side wall to stove 10"/ 25 cm B.
VENT TERMINAL CLEARANCES A= Clearance above grade, ve randah, porch, deck, or balcony [*12 inches (30 cm) minimum] 5 B= Clearance to window or door that may be opened [*12 inches (30 cm) minimum] C= C.
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT T YPE "GS" PIPE FOR GAS STOVES. SECURITY VENT ING SYSTEMS (SECURE VENT) Kits are avail able for vertical venting or horizontal venting.
When planning your installation, it w ill be necessary to select the proper length of vent pipe fo r your particular requirements . It is important to note when passing through a w all, the maximum allow able w all thickne ss is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintai ned.
STEP 7 . Slide the decorative wall thimble up to the w all surface and attach w ith the scr ews provided. Apply decorative brass or chrome trim if desired. FIG-14. FIG. 11 FIG. 12 FIG-13 FIG-14 NOTES : (1) The four wood screw s provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding.
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, w alls, roofs, enclosures, attic rafters , or other nearby combus tible surfaces. Do not pack air spaces with insulation.
NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the v ent pipe every 3 feet, to avoid excessive stress on the elbows, and po ssible separation. Wall straps are available for this purpose. FIG-18 (2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbow s.
CATHEDRAL CEILING INSTALLATION STEP 1. Follow installation steps 1 and 2 under Vertical Termination. STEP 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point.
Install 2 spring spacers around the flex pi pe. Slide the horizont al section of pipe over the flexible liner and install thr ough the wa ll thimble, ensure that this portion of pipe slides onto the vent te rmination cap. Slide the inside finished collar over the horizontal section of pipe and secure to wa ll using the screws provided.
VENTING INTO CLASS “A” CHIMNEYS Simpson GS Dura vent cap Cap Adapter Class “a Chimney Roof Flashing 4” flex liner inside Class “A” chimney Ceiling rafters Retro adapter GS Simpson Dura Vent pipe 4” x 6 5/8” This model is also certified and tested to vent into CLASS “A” wood.
INSTALLATION OF LOGSET and EMBERS INSTALLATION OF LOGSET and EMBERS INSTALLING THE GLOWING EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner. A bag of Rock Wool embers is provided for use on the burner. CAUTION: Use only the type of ember material supplied with this appliance.
OPERATING INSTRUCTIONS FOR YOUR SA FETY REA D BEFORE OPERA TING WA RNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by follow ing these instructions exactly.
MAINTENANCE AND TECHNICAL Periodically check to ensure that your "Direct Vent" system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow tips.
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark igniter Defective piezo igniter Check connections to igniter -If igniter connections ar.
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS Main Orifice #42 dms #53 dms Manifold pressure. 3.8” w c (0.95 kPa) 11” w c (2.74 kPa) Min. Manifold pressure. 1.1” w c (0.27 kPa) 2.7” w c (0.67 kPa) Supply Pressure.
The ENVIROGAS EG 28.FS.DV. will operate with no external power s upply. These models have a Millivolt gas control which uses the pilot flame to generat e enough electricity to operate the main burner.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve P.
ADJUSTING THE VENTURI 21 • Remove the ash shelf by undoing the screw at each end, pull shelf towards you. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
22 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of in stallation.
23 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG28-108 FREESTANDING PEDESTAL EC-002 220 ° F CERAMIC SPILL SWITCH EG28-109 FS PEDESTAL DOOR EC-006 SIT NOVA 820 NG VALVE 50% EG28-116 BURNER TRAY TO.
24 FIREBOX GOLD BAR EG28-128 FS BV STOVE TOP EG28124 FS DV STOVE TOP EG28-126 FS PEDESTAL DOOR EG28-109 FS PEDESTAL DOOR MAGNET EG28-056 FREESTANDI NG PEDESTAL EG28 108 UPPER GOLD BARS EG28-129 LOWER .
25 EG28 DOOR AND GAS TRAY ASSEMBLY EXPLODED Page 1 of 2 JULY 2001 GLASS RETAINER GLASS SET WITH TAPE EG28-097 GLASS EXTRUSIONS INNER DOOR WITH GLASS (B) EG28-103 DOOR LATCH BOLT EC-059 OUTER DOOR PAIN.
INSTALLATION DATA SHEET The installer for warranty purposes and future reference must re cord the following information. Please keep this information f or your records.
デバイスEnviro EG 28の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro EG 28をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro EG 28の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro EG 28の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro EG 28で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro EG 28を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro EG 28の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro EG 28に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro EG 28デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。