SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER By SHERWOOD INDUSTRIES EG-40 Fireplace Insert Vented Room Heater OWNERS MANUAL Installation And Operating Instructions For Model:- EG-40 FPI.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions.
TABLE OF CONTENTS 1 Code Appr ovals ..................................................................................................... 3 2 Specific ations .............................................................................................
3. ASSEMBL Y AND INST ALLA TION INSTRUCTIONS PREPARATION FOR INSTALLATION • Remove the packaging from the appliance, surround panels and log set, check to make sure there is no damage. Carefully check the glass door. Do not use the unit if it is damaged.
4.DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: A. Mantle pillar to stove 10"/ 25 cm B. Stove to 8" wide mantle 12"/ 31 cm Stove must sit on a non-combustible surface, the width and depth of the insert Maintain sufficient clearances for operation, service and maintenance OTHER DIMENSIONS A.
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30 cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30 cm) minimum] C= Cle.
5. VENTING WARNING; THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN CREATE HAZARDOUS SITUATIONS, EITHER THROUG H POOR VENTING OR BY OVERHEATING.
6. INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of ceramic fiber embers is provided for use on the front burner ember tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required.
7.OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by following thes e instructions exactly.
8. ROUTINE MAINTENANCE Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the unit is operating. Periodically check the pilot and burner flames CLEANING OF GLASS Do not clean glass w hen hot It will be necessary to clean the ceramic glass periodically.
9. TROUBLE SHOOTING Problem Cause Solution Spark will not light the pilot after repeated pressing of spark ignitor Defective ignitor Check connections to ignitor -If ignitor connections are good but t.
10. GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93 mm) #55 (1.32 mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” w c (.95 kpa) 11” w c(2.74 kpa) Min. Manifold pressures. 1.
11. ELECTRICAL REQUIREMENTS The ENVIROGAS EG-40 FPI. BV. will operate without an external electrical pow er supply. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners.
12. PARTS AND ACCESSORIES Service Parts available from y our local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 300 ° F(149 ° C) MR.
• There is a separate air shutter for each burner. • Remove one screw from the cove r plate located below the ash shelf. Loosen the other screw (do not remove) sw ing the cover plate out of the way and tighten screw dow n to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
16 13. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of in stallation.
14. INSTALLATION DATA SHEET The installer for warranty purposes and future reference must record the following information. Model: EG 40 FPI Name of Owner: __________________________________________ A.
デバイスEnviro EG-40の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro EG-40をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro EG-40の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro EG-40の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro EG-40で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro EG-40を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro EG-40の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro EG-40に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro EG-40デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。