EnviroメーカーEG40 BVの使用説明書/サービス説明書
ページ先へ移動 of 23
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE .
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLOWING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Caref ully r ead all the instructions in this manual rst.
T able of Contents 3 Safety Precautions..........................................................................................2 T able of Contents...........................................................................................3 Codes And Approv als.
BV: This V ented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be v ented through a conv entional chimney using a chimney liner kit. This appliance has been tested and approved f or installations from 0 feet to 2000 feet (610 m) above sea level.
5 WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENTING : This model must have a v ent opening in the rear of the unit. Conrm this and also check that the label on the right side panel door states “V ented Room Heater” . WARNING: This appliance has been designed to operate by dr awing combustion air and dilution air from the room.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y T ERMINATION : 7 .
8 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y S TRAIGHT V ERTICAL I NSTALLATION : Figure 5: Straight vertical installation. This basic venting conguration shown ar e rough guidelines only . Follow national and local codes for other installation options.
9 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : The ENVIRO EG40 will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to operate the main burners.
A DJUSTING T HE V ENTURIES : • There is a separate v enturies for each burner , see Figure 9. • R emove one screw from the cov er plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
11 Initial Inst alla tion F UEL C ONVERSION : WARNING: This conversion kit shall be installed by a qualied service technician in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work wi th gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting.
13 Second ar y Inst alla tion I NSTALLATION OF L OG S ET AND E MBERS : CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other foreign materials on the burners may create dangerous conditions.
Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. 4. Upon the rst light up, watch for ignition to ALL burner ports. If a long delay is noted: First, w ait for the appliance to cool down. • Open the front door of the appliance.
Oper a ting Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OR LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly .
16 R outine Maintenance and Ser vice Annually check to ensure that your V enting system is clear . Periodically check the pilot and burner . Check to see that all the burner ports are clean and clear . Check the pilot head for blockage. Check to ensure the pilot ame is blue with no or very small yellow tips.
T rouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor . • Check connections to ignitor . • If ignitor connections are good but there is no spark; replace ignitor .
P ar ts List Reference Number Part Description Part Number 1 120 °F (49 °C) Ceramic T emperature Sensor EC-001 2 220 °F (104 °C) Ceramic Spill Switch EC-002 3 S.
19 P ar ts List Reference Number Part Description Part Number BV Owner ’s Manual EG40-071 14 Pedestal EG40-080 15 Side Panel EG40-086 16 BV Stove T op EG40-087 Firebox Bafe EG40-088 Stove T op Ba.
P ar ts Diagr am - Chas sis EG 40 Body (Chassis) July 2004 20.
21 P ar ts Diagr am - Gas T r a y & Door EG40 Gas Tray & Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4.
W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arrant y on this gas product. This limited lifetime warr anty covers the appliance for a period of seven years from the date of installation.
23 Inst alla tion Da t a Sheet The following information must be r ecorded by the installer for warr anty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRES.
デバイスEnviro EG40 BVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro EG40 BVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro EG40 BVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro EG40 BVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro EG40 BVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro EG40 BVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro EG40 BVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro EG40 BVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro EG40 BVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。