EnviroメーカーHaven Direct Vent Fireplaceの使用説明書/サービス説明書
ページ先へ移動 of 41
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. DIRECT VENT FIREPLACE BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE I.
2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions.............................. ....................................................................................2 T able of Contents.............................................................................
4 DIRECT VENT ONLY: This appliance draws all of its air f or combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approv ed for installations from 0 feet to 4500 feet (1372 m) above sea level.
.
Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
2. Start the pilot by pr essing the gas contr ol knob and turning it to PIL O T . While holding the gas control knob in, press the piezo ignitor sever al times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 3).
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating A) Make sure the pilot is lit. B) T urn gas control knob COUNTER -CLOCKWISE to ON. C) Flip the burner switch to ON. D) T urn HI/LO knob to the desired ame height.
Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything.
10 Maintenance And Ser vice C LEANING D ECORATIVE S URFACES : P ainted and porcelain faces should be wiped with a damp cloth periodically . If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the nish, including cleaners, polish and nger prints.
11 Maintenance And Ser vice F UEL C ONVERSION : TO BE INST ALLED BY A QU ALIFIED SERVICE A GENCY ONL Y Please read and understand these instructions before installing. Figure 9: Removing valve cap. 5. Convert the burner orice(s): a) Remove the main burner orice with a inch deep sock et.
12 Maintenance And Ser vice b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key -wa y of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NTRODUCTION : This section of the owner’s manual is for the use of qualied technicians only . Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as wel l as the gas and electric systems.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y The framing boards ma y touch the top, side and back standoffs, but no insulation or other material can be placed between the frame and the standoffs. The gas line, inch NPT , can be brought to either the right side, the left side, or the bottom of the replace.
15 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 20. Top Mounting brackets. F RAMING M OUNT B RACKETS : Drywall Wood Framing Front T abs; bent up & screwed into the drywall Back T abs; bent up & screwed into the wood framing Figure 17.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Drywall Plywood Brick Drywall Plywood T ile Drywall Plywood Figure 21. Bottom Mounting Holes.6.
17 Combustible Header Combustible Facing (up to 1" (25mm) thick) 31 7 / 8 " (810mm) 7" (178mm) 3 1 / 2 " (89mm) 10" (254mm) 1 1 1 / 2 " (292mm) 10 1 / 4 " (260mm) 3 / 4 " (19mm) 5 / 8 " min (16mm) Figure 25.
1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier .
19 KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 W all thimble 1 4 oz tube R TV silicon.
Flue Pipe Adaptor Wall Framing Wall Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5/8" Flex Pipe Wire Spacers 9. Install the ex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the v ent termination cap.
21 W ARNING: Do not mix parts from diff erent vent manuf acturers’ s systems. EXCEPTION T O W ARNING: This product has been evaluated by Intertek for using a Direct V ent GS starting collar in conjunction with Secure V ent, Direct - T emp, and Ameri V ent Direct venting systems.
Figure 32. Vent Framing Through Wall/Ceiling. Figure 31. Vent Pipe Clearances. 2" (51mm) 7 1 1 / 16 " (195mm) 39" (991mm) Framing Joists/Studs 10” 10” Initial Inst alla tion QUALIFI.
23 0” (0m) 0” (0m) 10’ (4.72m) 15’ (7.09m) 15’ (7.09m) 20’ (9.45m) 32’ (15.12m) 17’ (8.03) 1 V ent Restriction Positions 39” (99cm) from the floor 2 3 4 5 25’ (1 1.81m) 30’ (14.17m) 10’ (4.72m) 5’ (2.36m) 5’ (2.36m) Figure 33.
W all framing Horizontal wall termination W all thimble fire stop Rigid Coaxial Pipe Elbow Initial Inst alla tion QUALIFIED INST ALLERS ONL Y H ORIZONTAL T ERMINATION : NOTES: 1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the stove), there should be at least inch (6.
25 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Step 3. T o install the Round Support Box/W all Thimble in a at ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 32.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y STEP 5. Cut hole in the r oof centered on the small hole placed in the roof from Step 2. The hole should be of sufcient size to meet minimum requirements for Clearance to Combustibles, as specied.
27 NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (914 mm), to avoid excessive stress on the elbows, and possible separ ation. W all straps are available for this purpose (see Figure 38).
I NSTALLATION O F E LECTRICAL W IRING F OR T HE O PTIONAL F AN K IT : Figure 40. Wiring Diagram For Gas Valve..
29 Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping ma y make the necessary gas connections to this appliance. GAS LINE CONNECTION • This replace is equipped with a certied exible pipe located on the right side of the unit.
Second ar y Inst alla tion QUALIFIED INST ALLERS ONL Y O PTIONAL F AN K IT I NSTALLATION : If the Haven is installed the burner and v alve assemblies must be remov ed. If the Haven is not installed the fan can be installed through an access hole at the lower r ear of the unit.
31 Figure 48. Install Fan Control Box. Figure 49. Install Fan Control Nut. Second ar y Inst alla tion 6. Re-install the screws f or the back cover and the stand-of f . 7 . Remove the two (2) screws holding the contr ol panel in place. Pull the panel out of the wa y .
Figure 52. Charcoal Pieces Installation. Figure 53. Ember Placement. Second ar y Inst alla tion 6. Install the two (2) grommets; place a 8-32 x ” bolt through each grommet then attach the bolt to the back cover using a ” sock et (see Figure 51) 7 .
33 Second ar y Inst alla tion.
Second ar y Inst alla tion I NSTALLATION OF S TEEL F IREBOX L INER OR O PTIONAL C ERAMIC F IREBOX L INER : NOTE: The ceramic liner is fragile and should be handled gently. Please ensure that it has not been damaged. Turn off the gas control knob and allow the unit to cool.
35 T roubleshooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature.
P ar ts List - Components Reference Number Part Description Part Number 1 120°F Ceramic Fan T emperature Sensor EC-001 2 S.I.T . Nova V alve NG Convertible 50-1421 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-01 1 3 Thermopile EC-012 3 Pilot Orice NG Threaded EC-019 3 Pilot Orice LP Threaded EC-020 3 Pilot Gasket EC-021 4 S.
37 P ar ts List - Options Referance Number Part Description Part Number 20 Firebox Liner - Bankers Brown Brick 50-1209 20 Firebox Liner - Arizona Stucco 50-1210 20 Firebox Liner - Red Brick 50-1225 21 Firebox Liner - Steel Black 50-1282 Fireplace Horizontal V ent Kit - 5 Feet (1.
P ar ts Diagr am - Components Haven Fireplace 20 1 1 19 6 8 10 3 4 18 5 9 17 2 7 16 15 14 13 1 12 21 The Haven - Components December 2005 38.
39 P ar ts Diagr am - F ascia .
40 W arr anty Sherwood Industries Ltd. offers a Limited Lifetime Warr anty on this gas product. This Limited Lifetime W arr anty covers the appliance for a period of seven years from the date of installation. This warr anty applies only to the original owner in the original location.
41 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
デバイスEnviro Haven Direct Vent Fireplaceの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro Haven Direct Vent Fireplaceをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro Haven Direct Vent Fireplaceの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro Haven Direct Vent Fireplaceの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro Haven Direct Vent Fireplaceで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro Haven Direct Vent Fireplaceを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro Haven Direct Vent Fireplaceの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro Haven Direct Vent Fireplaceに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro Haven Direct Vent Fireplaceデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。