SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 28 B Vented By SHERWOOD INDUSTRIES OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATIONOF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at once least annually by a qualified service person.
TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Venting 6 Installation of Log Sets and Embers 8 Operating Instructions 9 Maintenance and Technical 10 Tro.
4 DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 22"/ 56cm Rear Width: 22"/ 56cm Height: 27-1/2"/ 70cm* Depth 19"/ 48cm (*not including vent coupling) Shipping Weight: 210 lbs/95 kg CLEARANCES: A. Side wall to stove 10"/ 25cm B.
VENT TERMINAL CLEARANCES Figure 3 A= Clearance above grade, ve randah, porch, deck, or [balcony (*12 inches (30cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30cm) minimum.
VENTING This model must have a vent opening in the rear of the unit. Confirm this and also check that the label on the right side panel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM.
A. USING AN EXISTING CHIMNEY • Measure the height of the ch imney beforehand and purchase the appropriate kit. Never attempt to ov er stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked permanently in the open position.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required.
OPERATING INSTRUCTIONS FOR YOUR SA FETY REA D BEFORE OPERA TING WA RNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by follow ing these instructions exactly.
MAINTENANCE AND TECHNICAL Annually check to ensure that y our Venting system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow tips.
Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark igniter Defective piezo igniter Check connections to igniter -If igniter connections are good but there .
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS Orifice size #42 dms #53 dms Manifold pressure. 3.8” w c (0.95 kPa) 11” w c (2.74 kPa) Min. Manifold pressure. 1.1” w c (0.27 kPa) 2.7” w c (0.67 kPa) Supply Pressure.
The ENVIROGAS EG 28.FS.BV. will operate with no external power s upply. These models have a Millivolt gas control which uses the pilot flame to generat e enough electricity to operate the main burner.
14 PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valv.
ADJUSTING THE VENTURI • Remove the ash shelf by undoing the screw at each end, pull shelf towards you. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
16 WARRANTY Because of our high standards Sherwood Industries Ltd. c an offer a *Lifetime Warranty on all it’s gas products. Covered under this warranty are Cabinet Sides, Tops , Pedestals, Surround Panels and Chassis.
PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG28-108 FREESTANDING PEDESTAL EC-002 220 ° F CERAMIC SPILL SWITCH EG28-109 FS PEDESTAL DOOR EC-006 SIT NOVA 820 NG VALVE 50% EG28-116 BURNER TRAY TOP E.
18 FS BV STOVE TOP EG28124 FS DV STOVE TOP EG28-126 FS PEDESTAL DOOR EG28-109 FS PEDESTAL DOOR MAGNET EG28-056 FREESTANDI NG PEDESTAL EG28 108 FIREBOX GOLD BAR EG28-128 UPPER GOLD BARS EG28-129 LOWER .
19 EG28 DOOR AND GAS TRAY ASSEMBLY EXPLODED Page 1 of 2 JULY 2001 GLASS RETAINER GLASS SET WITH TAPE EG28-097 GLASS EXTRUSIONS INNER DOOR WITH GLASS (B) EG28-103 DOOR LATCH BOLT EC-059 OUTER DOOR PAIN.
INSTALLATION DATA SHEET The following information must be recorded by the inst aller for w arranty purposes and future reference. Model: EG 28 B vented Name of Dealer: ________________________________.
デバイスEnviro Vented EG 28 Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro Vented EG 28 Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro Vented EG 28 Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro Vented EG 28 Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro Vented EG 28 Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro Vented EG 28 Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro Vented EG 28 Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro Vented EG 28 Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro Vented EG 28 Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。