FMIメーカーVFB36NC1の使用説明書/サービス説明書
ページ先へ移動 of 24
For more information, visit www .fmiproducts.com W ARNING: If the information in this manual is not .
www .fmiproducts.com 108662-01L 2 SAFETy .
www .fmiproducts.com 108662-01L 3 .
www .fmiproducts.com 108662-01L 4 PRODUCT FEA TURES OPERA TION This rebox is designed for use with approved ANS I Z21 .1 1.2 deco rat iv e typ e unve nt ed room heat ers. (Physic al size limita tion s apply . Refer to minimum rebox requirements supplied with log heater.
www .fmiproducts.com 108662-01L 5 25 1 / 8 " 29 1 / 2 " 34 7 / 16 " 36 3 / 8 " Standoffs 22 1 / 2 " 4" 29 1 / 2 " 16 3 / 4 " 18 7 / 16 " 32 1 / 4 " 36.
www .fmiproducts.com 108662-01L 6 PRODUCT SPECIFICA TIONS Continued 36" AND 42" MODELS Note: If only one dimension is shown, the dimension is the same for both 36" and 42" mod- els.
www .fmiproducts.com 108662-01L 7 AIR FOR COMB USTION AND VENTILA TION The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation.
www .fmiproducts.com 108662-01L 8 DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Use this work sheet to determine if you have a conned or unconned space.
www .fmiproducts.com 108662-01L 9 VENTILA TION AIR This fresh air would come from an adjoining unconned space.
www .fmiproducts.com 108662-01L 10 IMPORT ANT : V ent-free gas log heaters add moisture to the air . Although this is benecial, ins tal lin g r ebo x i n r ooms wi tho ut enoug h ventilation air may cause mildew to form from too much moisture. See Air for Combustion and V entilation , page 7.
www .fmiproducts.com 108662-01L 11 55 5 / 8 " 39 3 / 8 " 34 1 / 2 " 27 3 / 4 " 0" CLEARANCE 0" CLEARANCE *10 1 / 2 " *10 1 / 2 " * These dimensions allow for min. Clearances to a 45° projected side wall. However , clearances to projected mantel trims and facings are allowed within a min.
www .fmiproducts.com 108662-01L 12 IMPORT ANT : If installing blower accessory (circulating models with louvers only), see Hard-Wiring Firebox, page 16. 3. Car ef ull y set reb ox in fro nt of roug h open - ing with back of rebox inside wall open - ing.
www .fmiproducts.com 108662-01L 13 INST ALLA TION Continued INST ALLING GAS LINE - .
www .fmiproducts.com 108662-01L 14 INST ALLA TION Continued Decide which way you intend to gain access into the bottom rear of the rebox to install the blower accessory . The lower front panel can be removed easily by snapping out the front with a at blade screwdriver .
www .fmiproducts.com 108662-01L 15 INST ALLA TION Continued bracket (see Figure 14). Secure speed control to bracket with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against bracket. 7. Remove knockout plug from louver panel by pressing top and bottom retaining clips (see Figure 1 1, page 13).
www .fmiproducts.com 108662-01L 16 3 . Using screws provided, fasten upper ang e of blow er brack et to hearth pan and end anges to leg stands (see Figure 16, page 15). Note: The wire assembly must be ar - ranged in front of and away from fan blades to reach power receptacle plug.
www .fmiproducts.com 108662-01L 17 INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 The outside air kit may be installed on the left side of the replace only . The vent can be installed through any outside wall a minimum of three feet below replace termination cap.
www .fmiproducts.com 108662-01L 18 REPLACEMENT P ARTS NOTICE: All accessories may Purc has e these acces sori es fro m your loca l de al er .
www .fmiproducts.com 108662-01L 19 ACCESSORIES Continued MANTELS 32" W ALL MANTELS W32TU - 32" Unnished, T raditional W32TO - 32" Oak Stain, T raditional W32CO - 32" Oak Stain, .
www .fmiproducts.com 108662-01L 20 1 2 3 6 7 9 28 29 4 8 14 12 13 1 1 16 15 10 17 18 19 24 25 26 23 27 22 21 20 5 P ARTS MODELS V32, V32A, V32S, V32AS, VFB32C, VFB32AC, VFB32NC, VFB32ANC.
www .fmiproducts.com 108662-01L 21 P ARTS This list contains replaceable parts used in your rebox. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
www .fmiproducts.com 108662-01L 22 1 2 3 4 8 12 13 14 15 21 24/25 23 20 19 18 16 29 30 1 1 31 5 28 32 10 9 6 26 22 17 P ARTS MODELS CUVF36C, V36, V36A, V36S, V36AS, V36ASH, V36H, V36AH, V36SH, VFB36AC.
www .fmiproducts.com 108662-01L 23 KEY P ART NUMBER DESCRIPTION V36S, V36AS V36ASH V36SH, VFB36NC1 VFB36ANC CUVF36C V36, V36A V36H, V36AH, VFB36C1 VFB36AC V42S, V42AS V42ASH V4.
108662-01 Rev . L 09/09 WARRANTy KEEP THIS WARRANTy FMI PRODUCTS, LL C LIMITED WARRANTIES New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free f.
デバイスFMI VFB36NC1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
FMI VFB36NC1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFMI VFB36NC1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。FMI VFB36NC1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。FMI VFB36NC1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
FMI VFB36NC1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFMI VFB36NC1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、FMI VFB36NC1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFMI VFB36NC1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。