FMIメーカーVFN24Rの使用説明書/サービス説明書
ページ先へ移動 of 26
UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED AS VENTED DECORATIVE APPLIANCES OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual.
2 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. 1. This appliance is only for use with the type of gas indicated on the rating plate.
3 105072 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1 , also known as NFPA 54*.
4 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
5 105072 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 105072 OWNER’S MANUAL LOG SIZING REQUIREMENTS Minimum Firebox Size Log Front Rear* Size Height Depth Width Width 18" 17" 14" 20" 14" 24" 17" 14" 26" 18.
8 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Heat Resistant Material (A) Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace INST ALLA TION Continued If Using Mantel You must have noncombustible material(s) above the fireplace opening.
9 105072 OWNER’S MANUAL Minimum Non- Combustible Material Minimum Non- Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12" 8".
10 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
11 105072 OWNER’S MANUAL Installation Items Needed Before installing heater, make sure you have the items listed below. • piping (check local codes) • sealant (resistant to propane/LP gas) • e.
12 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ON POSITION OFF POSITION Open Closed Equipment Shutoff Valve Figure 15 - Checking Gas Joints Gas Meter Equipment Shutoff Valve Gas Control Location Test Pressures Equal To or Less Than 1/2 PSIG (3.
13 105072 OWNER’S MANUAL Rear Log (#3) Peg Grate Prong Grate Prong Groove in Back of Log Groove in Back of Log Top Middle Log (#4) Hole Peg Figure 19 - Installing Crossover Log (#4) Figure 18 - Inst.
14 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. O F F P I L O T O N L O I H AUTO OFF ON OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
15 105072 OWNER’S MANUAL OPERA TING HEA TER Continued TO TURN OFF GAS TO APPLIANCE 1. Follow steps 1 thr ough 6 under Light- ing Instructions , page 14. 2. Depress contr ol knob and light pilot with match. 3. Keep contr ol knob pressed in f or 30 seconds after lighting pilot.
16 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Thermocouple Pilot Burner Figure 25 - Correct Pilot Flame Pattern Figure 26 - Incorrect Pilot Flame Pattern INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.
17 105072 OWNER’S MANUAL WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If front burner flame pattern shows yellow tipping, fol- low instructions at bottom of this page. Yellow flame on rear burner is normal.
18 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
19 105072 OWNER’S MANUAL TROUBLESHOOTING Continued Continued REMEDY 1. Contact local natural gas company 2. Clean burner(s) (see Cleaning and Main- tenance , page 17) or replace burner orifice(s) 3. Contact qualified service person 4. Replace burner orifice(s) 5.
20 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. REMEDY 1. This is common with most heaters. If noise is excessi ve, contact qualified ser - vice person 1. Open window to ventilate room. Stop us- ing odor causing products while heater is running 2.
21 105072 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
22 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ILLUSTRA TED PA R T S BREAKDOWN VFN18R VFN24R VFN30R 7 8 9 10 7 7 11 12 22 13 25 26 31 31 15 18 30 20 21 28 29 16 23 19 14 27 .
23 105072 OWNER’S MANUAL P AR TS LIST VFN18R VFN24R VFN30R This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. KEY PART NUMBERS NO. VFN18R VFN24R VFN30R DESCRIPTION QTY.
24 105072 UNVENTED NA TURAL GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated's Parts Department at 1-800- 888-2050 for referral information.
25 105072 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスFMI VFN24Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
FMI VFN24Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFMI VFN24Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。FMI VFN24Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。FMI VFN24Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
FMI VFN24Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFMI VFN24Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、FMI VFN24Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFMI VFN24Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。