920-087-04 (10-06) PT A C P A CKAGED TERMINAL AIR CON DI TION ERS & HEA T PUMPS Standard Control Remote Thermostat Seacoast Protected INS T ALL A TION & OPERA TION GUIDE.
2 920-087-04 Unit C omponents ............................................................................................................... ................................................................................ 2 Model N umber Code .......
3 920-087-04 Thank y ou for your decision to pu rchase the newly designed F riedrich Packaged T er min al A ir Conditioner ( PT A C ). W e are con fi de nt tha t y ou will fi nd this u nit a qu iet a nd ef fi cient e xa mple of F riedrich reliability .
4 920-087-04 P T AC Inst allation Recommenda t ions For proper P TAC unit per formance and max imum operating life please r efer to the minimum inst alla tion clear ances below: The abov e suggestions are for ref erenc e only and do no t represent all possible installation s.
5 920-087-04 Fried rich Digital Contr ol Fea tures The new F riedr ich digital PT A C has state of the ar t features to improv e guest comfor t, indoor air qualit y and conser ve energy .
6 920-087-04 Fried rich Digital Contr ol Fea tures C onti nued Instant Heat Heat Pump Mode H ea t p u mp m od e ls w il l a ut o ma t ic a l ly r un t he el e c tr i c he at e r t o quic kly bring the r oom up to temperature wh en initially energize d, t he n re tu r n to he at pu mp m o de.
7 920-087-04 Insta lla tion I nstr ucti ons PXDR 1 0 Drain Kit Internal Drain ( optional for new const ruction ) NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve be fore the wall sleev e is installed. 1 . Refer to Figure 3 below and locate the drain within the " Pr imar y" area for be st drainage.
8 920-087-04 External Drain (f o r n e w c o n s t r u c t i o n o r u n i t r e p l a c e m e n t) When using an exter nal drain system, the condensate is removed th rough either of t wo drain holes on the bac k of the wall sleev e . Select the drain hole whic h best meets your drainage situation and install the drain kit.
9 920-087-04 W all Sleeve Ins tallat ion Inst ruc tions (PD X WS ) NOTE: Insure that the unit is only installed in a wall str uct urally adequate to suppor t the unit including the sleeve, chassis and acc essorie s. If the sleeve projects more than 8 " in to the room, a sub base or other means of suppor t M UST be used .
10 920-087-04 3 . Drill t wo 3/ 1 6 " holes through each side of the sleeve approximately 4 " from top and 4" from b ottom of sleev e. Screw four #1 0 x 1" screws (included) or appropriate fasteners for your installation, through the hole s in the sides of the wall sleeve .
11 920-087-04 If the wall is thicker than allowed in the notes in Figure 6, a sheet met al wall sleeve e x ten sion and fl a s h i n g MU S T be u s e d .
12 920-087-04 Plastic handles Plastic grommets 1 . Remove the center suppor t and weatherboard if st ill in stalled in the sleeve . 2. Inser t six plastic grommets into the gr ille openings from t he outside of the gr ille as shown in Figure 9.
13 920-087-04 A . Electrical R atin g T a bles All 230 / 208 volt units ar e equipped with power cords. S ee Appendix A on page 2 1 for w iring in str uc t ions on 2 65V units. NOTE : Use Copper Conduc tors ON L Y . Wire sizes are per NEC, check local c odes for over seas ap pli ca tions.
14 920-087-04 Section III – Ch assis Instal lati on 1 . Remov e the weatherb oard and center suppor t from the sleeve (if still in plac e ). Be sure an outdoor gr ille is attache d . Check to be sure t he wall sleeve , ex tension ( if used) , grille, and drain kit ar e installed properl y befor e chassis installation .
15 920-087-04 4. Center the chassis in the pre -inst alled sleev e and care ful ly push the chassis until t he chas sis fl ange and gas ke t c o nt ac t the slee v e fl ange. If a remote t hermost at is to be installed, pr oceed to page 18, Step 1. For a 265 V unit , proceed to A ppendix A , Step 1.
16 920-087-04 Digital Contr ol U ser Input Con fi gu ra t io n The adjustable c ontrol dip switches are loc ated at the lower le f t hand por tion of the digit al Smar t Center . The inputs are onl y visible and acc essible with the f ront cov er removed from the PT AC.
17 920-087-04 Digital Contr ol Opera tion Te m p e r a t u r e D i s p l a y The F r iedrich digit al PT AC is shipped from the factor y to display the desired room temperature on the LED readout .
18 920-087-04 R Y W B GL GH C D1 D2 F1 F2 JP1 12 34 56 78 ON DIP Re mote T hermostat and Low Volta ge Contr ol Connections T o contr ol the unit with a wall mounted ther mostat follow the steps below : 1 ) Wit h the front cover remov ed loc ate the low voltage terminal strip at the lower por t ion of the Smar t Center .
19 920-087-04 The vent control lev er is loc ated behind the front cover on the lef t side of the unit. The unit is shipped in the closed p osition with a lock ing screw in place. The screw must be removed to operate the lev er . W hen the lever is back, ( OPEN) , outside air is m i x e d with ind oor a ir .
20 920-087-04 I. Star t - up Checklist Inspect all components and accessories for damage before and after installation. Check installation for compliance with all national and local codes and ordinances. Read and follow all manufacturer's installation instructions.
21 920-087-04 Appendi x A : Electr ica l W irin g for 265 V olt Models 1 . Remove the four control box retaining screws (A ) and open the control box. 2. Pull the c hassis power lead wires (B ) (located on the bot tom- right side of the c ontrol box ) through the plastic bushing so they are located inside the c ontrol bo x.
22 920-087-04 J. Routine Maintenance 1 . Clean the unit air intake fi lter at least ev er y 30 0 to 350 hour s of operation. Clean the fi lters with a mild detergent in warm water and allow to dr y thoroughly before reinstalling.
23 920-087-04 K . Basic T roubleshooting T echniqu es Being familiar with the sequenc e of operation on Standard Contro lled O perating Units or the operation of the Remote Therm ostat Controlled Unit s is impor tant. The following questions and answers ma y help to identif y per formance problems.
24 920-087-04 Dia gnostics The F r iedrich Smar t Center c ontinuously monitors the PT A C unit operation and will store ser vice c odes if c er tain condit ions are w i t ne s s e d. I n s o me c a s e s t he u n it m ay t a ke a c t i on a n d s h u t t h e unit of f until conditions are c orrec ted.
25 920-087-04 Friedr ich P TAC Acce s sorie s NE W CO NSTRU CTIO N AC CE S SO RIES MODEL NUMBER DESC RIPTION PHO T O PDX WS WA LL SL EE VE Ga lva niz ed zin c c oa ted ste el is pre pa re d in an 1 1- s t e p p r o c e s s , t h e n p ow d e r c o a t e d w i t h a p o l y e s t e r fi nish and cured in an oven for e xceptio nal durability .
26 920-087-04 ADDITIONAL A CCE SSORIES MODEL NUMBER DESC RIPTION PHO T O PXSE SLEEVE EX TENSION RETR OFIT KIT Galv aniz ed zinc coated s t e e l , 2 . 4 " s l e e v e e xt e n s i o n a tt a c h e d t o t h e ro o m s i d e o f t h e sleeve to allow for the installation of a PD - Serie s F riedr ich PT AC in a T -Ser ies sleeve .
27 920-087-04 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedr ich.com PD-SERIES PACKAGED TERMINAL AIR CONDITIONERS LIMITED WARRANTY SAVE THIS CERTIFICA TE. It gives you spec ific rights, you may also have other rights w hich may vary from state to state and province to province.
F riedrich Air Condition ing Co. Post Of fic e Bo x 15 4 0 • San Antonio, T exa s 782 95 - 1 54 0 420 0 N. Pan Am Expr es sway • San A ntonio, T exa s 7 8 218 -5212 (210) 357 - 4 4 00 • F A X (210) 3 57 - 4 48 0 w w w. frie drich.com Print ed in t he U.
デバイスFriedrich HEAT PUMPSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich HEAT PUMPSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich HEAT PUMPSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich HEAT PUMPSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich HEAT PUMPSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich HEAT PUMPSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich HEAT PUMPSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich HEAT PUMPSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich HEAT PUMPSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。