Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 4 = Contains updated information. 15 Appliance Setup A. Remove the Packaging 55 B. Remove Screen Package Assembly 55 C. Remove the Shipping Materials 55 D. Removing Fixed Glass Assembly 55 E.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC).
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 8 H. Requirements for the Commonwealth of Massachusetts serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 9 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 1 1 I. Lighting Instructions (IPI) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • The IPI system may be operated with two D-cell batteries.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 12 J. Lighting Instructions (Standing Pilot) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • If your fi replace must be deactivated for service or an extended period of time, follow the instructions below .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 13 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance off and allow it to completely cool. • Remove and clean fi xed glass assembly .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 15 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 16 (Either cobrahead or SIT) PRODUCT SPECIFIC Figure 3.1 IPI Flame Patterns Figure 3.2 Standing Pilot Flame Patterns.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 18 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 19 In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Sections 3.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 20 D Clearance to Ceiling 30 in. (762 mm) 0 in. 0 in. T O LEVEL OF ST ANDOFFS Combustible Object 36 in. (914 mm) 0 in. Combustible flooring may be installed next to the front of the appliance.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 21 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular W all T op of Appliance Drywall A B D.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 22 Gas, Wood or Fuel Oil T ermination Cap B Gas T ermination Cap ** A * * If using dec orat ive cap cover(s), this dis tance may need to be increased. Refer t o the installation instruc tions supplied with the decorative cap c over.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 23 CAUTIO N: IF E X TERI OR WAL LS ARE FI NIS HED W ITH VI NY L SID ING , IT IS SUGG E STE D THA T A VIN YL PR O TECTOR K IT BE I NST ALL ED.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP and SLP venting systems. Refer to Sec- tion 17.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from dif ferent manufacturers.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 25 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 26 H 1 V 1 Figure 7.4 One Elbow 1. T op V ent - Horizontal T ermination - (continued) Figure 7.5 T wo Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 27 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 min. V 1 +V 2 ma x. H 1 +H 2 max. 1 2 in. /3 05 mm 24 f t / 7 . 32 m (DVP) 19 ft /5 .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 28 2. T op V ent - V ertical T ermination No Elbow Figure 7.7a 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 29 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 30 3. Rear V ent - Horizontal T ermination (DVP only) Figure 7.10 Figure 7.1 1 No Elbow One 45° Elbow 18 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 31 3. Rear V ent - Horizontal T ermination (DVP only) - (continued) T wo Elbows Figure 7.12 Figure 7.13 Three Elbows H 2 V 1 H 1 Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 32 4. Rear V ent - V ertical T ermination (DVP only) One Elbow Figure 7.14 T wo Elbows Figure 7.15 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 33 4. Rear V ent - V ertical T ermination (DVP only) - (continued) Three Elbows Figure 7.16 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of vertical, but can- not exceed 26 ft (7.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 34 * When using SLP pipe, minimum clearances from the vent pipe to combus- tible materials at inside wall firestops are: T op: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP Pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 36 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 37 CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 38 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the vent cap has been removed it CANNOT be reattached. • Attach the fi rst vent section (it will snap into place).
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 39 C. Secure and Level the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 40 A B A B 1 0 10 Inst alling V ent P ipe A. Assemble V ent Sections (DVP only) Attach V ent to the Firebox Assembly Note: The end of the pipe sect ions wi th th e lanced tabs will fac e toward the appliance.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 41 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance • Attach an DVP-SLP24 adapter to the starting collar of the appliance.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 42 Figure 10.8 Securing V ertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections D. Secure the V ent Sections • V ertical runs of DVP pipe must be supported every 8 ft. (2.44 m) after the 25 ft.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 43 Cut hole 1/8 in. (3 mm) greater in size than pattern of support box as it is projected onto roofline. 2 in. (51 mm) minimum below finished ceiling Cathedral ceiling support box Level F .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 44 Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.) - Minimum height from roof to lowest discharge opening. 24 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 45 I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap over the outer fl ue of the pipe section.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 46 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 47 1 1 11 Shrouds • Chase top shrouds may be fi eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as speci fi ed. Improper construction may overheat chase top.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 48 Min. Base Dim Min. Height Min. Base Dim Figure 1 1.2 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min. Opening Width Min. Base Dimension Minimum Height Figure 1 1.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 49 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician using Hearth & Home T echnologies specified and approved parts.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 50 Red or Black Button Figure 13.1 Ignitor Button B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. • A 1 10 V AC junction box MUST be installed for use with a fan or remote control.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 51 GRN ORG BLK ORG Control Box To Junction Box Battery Pack 3V Adapter BLK BRN RED RED V alve WHT + - + - W all Switch WHT GRN* * GRN wire only used with optional wall switch WSK-ML T -HTL Ignitor Flame Sensor Pilot Assembly E.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 52 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 13.5): • The power supply for the appliance must be brought into a switch box.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 53 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendi.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 54 0 in. 0 in. 0 in. Finish wall material may be combustible - T op and Sides High T emperature Sealant (300° F/149° C min.) T op and Side Seal Joint B. Facing Material • Cover the metal front faces with non-combustible materi- als only .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 55 1 5 15 Appliance Setup A. Remove the Packaging Remove the shrink fi lm, corrugated top cap, bottom cap and column protectors from the appliance. The appliance should look as shown in Figure 15.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 56 G. Place the Rockwool W ARNING! Risk of Explosion! Follow rockwool place- ment instructions. DO NOT place rockwool directly over burner ports. Replace rockwool material annually . Improp- erly placed rockwool interferes with proper burner opera- tion.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 57 N. Install Hood • Locate the four screws just inside the upper section of the appliance. • Slide the hood into position uncer the screw heads. • T ighten the four screws. See Figure 15.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 58 P . Close the Screen Assembly • Make sure the screen magnetic touch latches are in the open position. See Figure 15.12. • Hange the screen on the shoulder screws in the columns. See Figure 15.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 59 A. Standing Pilot Ignition System 1 6 16 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 60 T roubleshooting (continued) Sym ptom Possib le Caus e Cor rec tive Ac tion 3. (Co ntinued) C. Failed valve. T urn th e valve knob to the O N positi on. Place th e ON/OFF sw itch in the O N positi on.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 61 B. Intelli fi re Ignition System Sym ptom Possib le Caus e Cor rec tive Ac tion 1 . Pilot won’t light .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 62 Intelli fi re Ignition System - (continued) Sym ptom Possib le Caus e Cor rec tive Ac tion 4.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 63 1 7 17 Reference Materials Electrical Access Alternative Gas Access 1-3/4 in. (44 mm) 34-1/2 in. (876 mm) 1-1/2 in. (38 mm) 15-3/4 in. (400 mm) 8 in. (203 mm) 2-3/8 in. (60 mm) 31-1/2 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 64 B. V ent Components Diagrams Figure 17.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pipe inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 12 19 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 65 B. V ent Components Diagrams ( continued ) Figure 17.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 66 B. V ent Components Diagrams ( continued ) Figure 17.4 DVP V ent Components DVP-TB1 Basement V ent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7 - 3/8 i n. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 67 B. V ent Components Diagrams ( continued ) Figure 17.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 68 B. V ent Components Diagrams (continued) Figure 17.6 DVP V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 69 Figure 17.7 SLP Series V ent Components B. V ent Components Diagrams (continued) Effec tive Height /Length Pip e inches mm SLP 4 4 10 2 SLP6 6 1 52 SLP 12 1 2 305 SLP2 4 24 61 0 SLP36 36 91 4 SLP 48 48 1 21 9 SLP 6A 2 - 6 5 1 - 152 SLP12A 2 - 12 51 - 305 8-3/4 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 70 B. V ent Components Diagrams (continued) Figure 17.8 SLP Series V ent Components 1 in. (25 mm) 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-1/4 in. (184 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 13 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 71 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) SLP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm SLP-HRC-ZC-SS (Not approved for NDV4842) (Not approved for NDV4842) B.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 72 Part number list on following page. Log Set Assembly 3 1 4 2 30 in. Novus Circulating - DV 13 11 12 9 17 18 24 23 25 28 27 26 20 21 19 10 22 5 6 7 8 16 14 15 ND V3630, ND V3630i C.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 73 C. Service Parts (continued) I M P O R TA N T : T H I S I S DAT E D I N FO R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 74 C. Service Parts (continued) NDV39 33, NDV 3933i Part number list on following page. Log Set Assembly 33 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 75 C. Service Parts (continued) NDV39 33, NDV 3933i I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 76 C. Service Parts (continued) NDV 4236, ND V 4236i Part number list on following page. Log Set Assembly 33 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 77 C. Service Parts (continued) I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 78 C. Service Parts (continued) ND V 4842, N D V 4842i 13 11 12 10 9 17 18 21 22 20 19 28 27 26 25 24 23 5 6 7 8 16 14 15 Part number list on following page. Log Set Assembly 3 1 4 2 42 in.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 79 C. Service Parts (continued) I M P O R TA N T : T H I S I S D A T E D I N F O R M A T I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 80 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 81 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 82 I M P O R TA N T : T H I S I S D AT E D I N F O R M AT I O N . W h e n r e q u e s t i n g s e r v i c e o r r e p l a c e m e n t par ts for your appliance please provide model number and serial number .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 83 D. Optional Components Model # Descri ption NDV3 63 0 T op /rear dir ect vent s tand ing pil ot, natu ral gas , 36 ” fra ming wi dth, 30 ” view ing glas s NDV3 63 0L T o p/rea r direc t vent sta nding pi lot, L .
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 84 D. Optional Components (continued) Model # Descri ption NDV4236 T o p/rear d irec t vent sta nding p ilot, n atura l gas, 42 ” fra ming wi dth, 36 ” view ing glas s NDV4236 L T op /rear dir ect vent s tand ing pil ot, L.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 85 A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud 20 in. [508 mm] 17 in. [432 mm] 9-3/8 in. [238 mm] TCG375 T erra Cotta Cap LDSCP-M Shroud Leg Multipack (not shown) See your Heatilator dealer for a complete listing of optional components.
Heatilator • Novus NDV Series • 4055-187 Rev . V • 1/12 86 E. Contact Information - NOTES - ________________________________________________________________________________ _____________________.
デバイスHearth and Home Technologies 4055-187の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies 4055-187をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies 4055-187の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies 4055-187の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies 4055-187で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies 4055-187を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies 4055-187の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies 4055-187に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies 4055-187デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。