5100-I W OOD INSER T 1445 Nor th Highwa y Colville, W A 99114 SA VE THESE INSTR UCTIONS www .quadrare .com P ar t 250-1960 Rev B J anuar y 30, 2004 O - T L Tested and Listed by Beaverton Oregon USA OMNI-Test Laboratories, Inc. C R PRIOR T O FIRST FIRE : Remove all labels from glass .
5100-I W OOD INSERT P age 2 Jan uar y 30, 2004 R 250-1960 Re v B Hearth & Home T echnologies welcomes y ou to our tradition of e xcellence! In choosing a Quadra-Fire appliance, y ou hav e our assurance of commitment to quality , durability , and perf or mance.
P age 3 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B SAFETY & O VER VIEW OF APPLIANCE Dimensions ----------------------------------------------------- 4 Minimum Clearances to Comb usti.
5100-I W OOD INSERT P age 4 Jan uar y 30, 2004 R 250-1960 Re v B DIMENSIONS T OP VIEW SIDE VIEW FR ONT VIEW STD 47” 30-1/2” Large 51-1/4” 34-1/4” P anel Size A B A B 39-1/8" (994mm) 26-3/.
P age 5 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B SERIAL NUMBER LABEL LOCA TION: ON RIGHT SIDE OF INSER T AS Y OU F A CE THE APPLIANCE In Canada a full length 6” (152mm) S635 ue liner required as per ULC S628. NO TE: When installling into a masonr y replace, the re- place must be built to UBC Chapter 37 standards.
5100-I W OOD INSERT P age 6 Jan uar y 30, 2004 R 250-1960 Re v B A V OID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must hav e at least 2 inches (51mm) of air space clearance around t he chimney .
P age 7 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PR O TECTION ASSOCIA TION (NFP A) ST AND ARD 211.
5100-I W OOD INSERT P age 8 Jan uar y 30, 2004 R 250-1960 Re v B Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to.
P age 9 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B 1. An outside air inlet m ust be provided for combustion and must remain clear of leav es, debris, ice and/or snow . It must be unrestricted while unit is in use to pre vent room air star v ation which can cause smok e spillage and an inability to maintain a re.
5100-I W OOD INSERT P age 10 Jan uar y 30, 2004 R 250-1960 Re v B MASONR Y FIREPLA CE USING DIRECT -CONNECT METHOD Refer to: Clearances to Comb ustibles on page 5, Canadian Installation requirements on page 12, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 16.
P age 11 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B F A CT OR Y BUIL T ZERO CLEARANCE FIREPLA CE (USA INST ALLA T ONS ONL Y) The Quadra-Fire 5100-I Inser t is listed to UL Standards f or.
5100-I W OOD INSERT P age 12 Jan uar y 30, 2004 R 250-1960 Re v B INST ALLA TION IN CANAD A MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INT O F A CT ORY-B UIL T FIREPLACES ARE PR OHIBITED IN CAN.
P age 13 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B NO TE: The 5100-I requires replacement of combustion air . If y our home is fairly air-tight, it is receommend that you install outside air . If you are installing into a Mobile Home, outside air is required.
5100-I W OOD INSERT P age 14 Jan uar y 30, 2004 R 250-1960 Re v B BLO WER REPLA CEMENT INSTRUCTIONS P ar t 832-1991 for Serial Numbers 131586 and below P ar t 832-3190 for Serial Numbers 131587 and abov e Figure 14A NO TE: When the speed control is turned clockwise , it will clic k on to high speed.
P age 15 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B ST AND ARD Size: 30-1/2” h x 47”w 831-1452, Gold T r im SP-51S-NL, Nick el T r im Figure 15A Figure 13B Do not tighten sides until.
5100-I W OOD INSERT P age 16 Jan uar y 30, 2004 R 250-1960 Re v B ZER O CLEARANCE ADJUST ABLE TRIM SUPPOR T , 2” to 10” P ar t No. ADJSPT -12, size 12” x 50” Included in Kit: ( 1) T r im T op .
P age 17 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B WOOD SELECTION AND ST ORA GE Burn only dry seasoned wood. Dr y , well-seasoned wood will not only minimize the chance of creosote f or mation but will give you the most efcient heat output.
5100-I W OOD INSERT P age 18 Jan uar y 30, 2004 R 250-1960 Re v B BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high f or 5 to 15 minutes or longer f or very large pieces, close the Star t-Up Air Control (right side) by pulling it out.
P age 19 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B AIR QU ALITY AND Y OUR QU ADRA-FIRE INSERT In recent y ears there has been an increasing concer n about the quality of our air . Much of the b lame f or poor air quality has been placed on the burning of wood for home heating.
5100-I W OOD INSERT P age 20 Jan uar y 30, 2004 R 250-1960 Re v B MAINTENANCE CARE AND CLEANING OF PLA TED SURF A CES IMPORT ANT : Y ou must clean all the ngerpr ints and oils from the plated surfaces bef ore ring the inser t f or the rst time.
P age 21 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B BRICK REPLA CEMENT INSTR UCTIONS FIREBO X BRICK SET , P AR T 832-1970 The rebo x of your Quadra-Fire 5100-I Inser t is lined with high quality rebr ic k which has e xceptional insulat- ing proper ties.
5100-I W OOD INSERT P age 22 Jan uar y 30, 2004 R 250-1960 Re v B SER VICE P AR TS 832-3100 Grille Assembly , Gold 832-3100NL Grille Assembly , Nick el 831-1520 Mantel Deector , 5” 831-1530 Mante.
P age 23 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B Lifetime Warranty LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
P age 24 Jan uar y 30, 2004 250-1960 Re v B R A TTENTION INST ALLER: Please return this man ual to the homeo wner when installation is complete ..
デバイスHearth and Home Technologies 5100-Iの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies 5100-Iをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies 5100-Iの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies 5100-Iの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies 5100-Iで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies 5100-Iを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies 5100-Iの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies 5100-Iに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies 5100-Iデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。