1 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODELS: NA TURAL GAS PROP ANE CFL-18NG-C CFL-18LP-C CFL-24NG-C CFL-24LP-C CFL-30NG-C CFL-30LP-C ST -CFL-24NG.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ D.
3 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 = Contains updated information. T able of Contents 1 Introduction A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 4 opening provided by the fi replace chimney damper to vent the fl ue products must not be less than 51 square inches (328 cm 2 ). The chimney damper MUST be fi xed in a man- ner to maintain the minimum permanent vent opening.
5 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODEL CFL-18-C MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 1/2 ” (750mm) REAR WIDTH : 19 1/2 ” (521mm) DEPTH.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 6 Figure 2. DAMPER CLAMP OPEN DAMPER These models contain complete gas-burner , grate(s), and log components needed. Use caution when handling logs to avoid damage.
7 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI 7. T est fi re the unit after referring to the SAFETY INFOR- MA TION and LIGHTING INSTRUCTIONS found in Section 3 in this manual, or on the label plate assembly found on the gas-burner .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 8 • If a remote control is used, the receiver cannot be placed under the burner . If possible, place the receiver outside the combustion chamber . • If the receiver must be placed in the combustion chamber , the protective heat shield MUST be used.
9 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Upon completing the gas line connection, a small amount of air will be in the lines. When fi rst lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 10 Lighting Instructions (IPI) The IPI system must be operated with two D-cell batteries. 1. Turn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner.
11 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 12 A. Standing Pilot Ignition System 4 4 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
13 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) c. V alve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 14 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring.
15 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 16 Service Parts Diagram CFL-18NG-C, CFL-18LP-C A. Service Parts 5 5 Reference Materials Part number list on following page. Log Set Assembly 5 2 4 9 8 6 1 3 10 7 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov .
17 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-18NG-C, CFL-18LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 18 Service Parts Diagram Service Parts CFL-24NG-IPI, CFL-24LP-IPI Part number list on following page.
19 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 20 Service Parts Diagram Service Parts CFL-24NG-C, CFL-24LP-C Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov .
21 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-24NG-C, CFL-24LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 22 Service Parts Diagram Service Parts CFL-30NG-C, CFL-30LP-C Part number list on following page. Log Set Assembly 11 12 13 14 15 16 17 10 8 9 5 11 7 1 3 2 4 6 Beginning Manufacturing Date: Nov .
23 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-30NG-C, CFL-30LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 24 Service Parts Diagram Service Parts ST -CFL-24NG-B, ST -CFL-24LP-B Part number list on following page. Log Set Assembly 11 12 9 8 1 10 7 2 4 3 5 6 13 14 15 16 17 18 19 20 Beginning Manufacturing Date: Nov .
25 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 ST -CFL-24NG-B, ST -CFL-24LP-B Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 26 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnolo.
27 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 28 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo CFL-18LP-Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo CFL-18LP-Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo CFL-18LP-Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo CFL-18LP-Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo CFL-18LP-Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo CFL-18LP-Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo CFL-18LP-Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo CFL-18LP-Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo CFL-18LP-Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。