Heat & Glo LifeStyleメーカー6000TRI-SPの使用説明書/サービス説明書
ページ先へ移動 of 34
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 3 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists ........................................................
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 5 IT E M / PI ÈCE CO M MO N P A RTS / PI ÈCE S CO MM UNES SERI A L # / N° D E SÉRI E P A RT NUM BER / N° DE PI ÈCE 1 S urr.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 6 (NG , LP) Exploded Part s Diagram (GN, PL) Vue éclatée des pièces Service Parts Beginning Manufacturing Date: 7-03 Ending M.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 7 (NG , LP) Exploded Part s Diagram (GN, PL) Vue éclatée des pièces Service Parts Beginning Manufacturing Date: 7-03 Ending M.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 9 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 10 Figure 1. Diagram of the 6000TRI-IPI, 6000TRI-SP TOP VENT COLLARS REAR VE NT COLL ARS GAS LIN E ACCESS EL ECTR ICAL ACCE SS G.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 11 3 Inst alling the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fireplace within a room. Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front .
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 12 Framing should be constructed of 2 X 4 lumber or heavier . A . ............. 42”* B . ......... 38 1/2” C . ............... 22 ” D . ......... 42 3/4” E . ......... 27 7/8” Figure 3.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 13 Figure 4. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . D V P 9 0 S T 12- 9/16 11 - 1/ 4 7-1/4 1-1 /4 TYP 1/2 TYP 8-9/1 6 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 14 Figure 5. V ent System Component s and T ermination Kits Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP-series direct vent pipe components and terminations (see Figures 4 and 5).
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 15 Figure 6. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7).
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 16 HORIZONT AL VENTING Kit No. H Max. Run DV P- TR AP 24" (610 mm) Figure 1 1. Corner Installation NOTE: This model is tested and approved to use 45° elbows in corner inst allations.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 17 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 18 Figure 14. V enting with T wo 90° Elbows VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 19 Figure 16. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 20 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H (FT . ) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 21 ! B. Inst alling V ent Components After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly .
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 22 3. Continue Adding V ent Component s W ARNING: INST ALLA TION OF THIS FIRE- PLACE REQUIRES THE USE OF HEA T SHIELD 570-290 ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM. Figure 20 T o Inst all the Heat Shield: 1.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 23 5. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 24 Figure 28. T rapezoid T ermination Cap 7 1/4” (184mm) Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previously cut and framed hole.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 25 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. V ent T ermination Minimum Clearances A = 12" ....................... clearances above grade, ve ran- da, porch, deck or balcony B = 12" .
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 26 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 27 ! ! Step 6. The Gas Control Systems W ARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. The types of gas control systems used with this model ar e Intermittent Pilot Ignition (IPI) and Standing Pilot Ignition (SP).
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 28 Figure 35. Gas Supply Line • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 29 Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram IGNITI ON MODULE 3 V AC TRANSFO RMER 3 V AC GRN OR G INTERMITT EN.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 30 Figure 38. Fan Wiring Diagram NOTE: IF ANY OF THE ORIGINAL WI RE AS SUPPLIED W IT H THE APPLIANCE MUST BE RE PLACE D, IT MUST BE REPLACE D W ITH TYPE 105 C RATED WIRE.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 31 Step 10. Finishing Figure 39 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 32 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 33 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev . F • 5/05 34 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and mai.
デバイスHeat & Glo LifeStyle 6000TRI-SPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle 6000TRI-SPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle 6000TRI-SPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle 6000TRI-SPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle 6000TRI-SPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle 6000TRI-SPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle 6000TRI-SPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle 6000TRI-SPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle 6000TRI-SPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。