Heat & Glo LifeStyleメーカー8000CF-OAK-IPIの使用説明書/サービス説明書
ページ先へ移動 of 61
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 1 Models: 8000CF-OAK-IPI 8000CFLP-OAKIPI • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: _________________.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 4 Î = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 45 B. Facing Material . . . . . . . . . . . . . . . . . . . .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 5 B. Limited Lifetime W arranty Î.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 6 B. Limited Lifetime W arranty (continued).
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC).
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dw.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 19 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 21 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .........................
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 22 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 24 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 One Elbow T wo Elbows T op V ent - Horizontal T ermination V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 6 ft.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 25 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. V 1 + V 2 Min. H 1 + H 2 Max. 1 ft. 305 mm 3 ft. 914 mm 1 ft.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 26 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/termination of f the top of the appliance, the fl ue restrictor should be used. V 1 V 1 = 50 ft.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 27 Figure 7.1 1 T wo Elbows H 1 V 1 V 2 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum 1 ft. 305 mm 3 ft. 914 mm * * * 2 ft. 610 mm 6 ft. 1.8 m * * * 4 ft. 1.2 m 12 ft. 3.7 m * * * V 1 + V 2 + H 1 = 50 ft.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 28 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 29 A 12 in. 10 in. B Figure 8.6 W all Penetration B. W all Penetration Framing A* B 57-1/2 in. 56-1/2 in. Figure 8.5 Horizontal V enting Clearances to Combustible Materials 3 IN. TOP CLEARANCE HEA T SHIELD HEA T SHIELD WA LL WA LL SHIELD FIRESTOP 1 IN.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 30 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 31 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 32 A. Attaching Sheetrock Ledges Attach sheetrock ledges together using the attachment holes (see Figure 9.1). Figure 9.1 The sheetrock ledges will attach to the top of the unit (see Figure 9.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 33 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 34 PILOT PLA TE Figure 9.8 Note: E n s u r e p i l o t p l a t e i s i n p l a c e . T h i s w i l l e n s u r e p i l o t stabilit y ( see Figure 9.8) F . Checking Pilot Plate Figure 9.7 Re-install grate in unit RE-INSTALL INTO THE UNIT E.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 35 1 0 10 Inst alli ng V ent Pipe A. Assemble V ent Sections Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 36 B. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl ue of the slip section over the outer fl ue of the pipe section.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 37 D. Disassemble V ent Sections • Rotate either section (see Figure 10.9) so the seams on both pipe sections are aligned as shown in Figure 10.10. • Pull carefully to separate the pieces of pipe.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 38 E. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.1 1) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 39 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.15 Figure 10.15 TERMINA TION CAP G. Install V ertical T ermination Cap • Attach the ve.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 40 Figure 10.16 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 41 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 42 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 43 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 44 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 45 A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 46 1 2 4 6 7 8 10 9 A. Remove Fixed Glass Assembly See Section 14.I. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 47 G. Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 48 H. Install the Log Assembly Log Assembly: LOGS-8OAK If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 49 STEP 5: (SR V2057-723): Mate the top of log 4 with the right metal tab on log 3. The bottom of log 4 should touch the inside face of the right grate tine. 2 3 1 2 3 1 5 4 2 3 5 6 STEP 7: (SR V2057-725): Place log 6 on log 2 as shown.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 50 M. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 51 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 52 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 53 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 54 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 55 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 56 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 57 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI appliances only.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 58 C. Service Parts Part number list on following page. Service Parts Diagram 8000CF-OAK-IPI Beginning Manufacturing Date: Jan.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 59 C. Service Parts List 8000CF-OAK-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 60 Intermittent Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List 8000CF-OAK-IPI Beginning Manufacturing Date: Jan.
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev . R • 6/09 61 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
デバイスHeat & Glo LifeStyle 8000CF-OAK-IPIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Heat & Glo LifeStyle 8000CF-OAK-IPIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHeat & Glo LifeStyle 8000CF-OAK-IPIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Heat & Glo LifeStyle 8000CF-OAK-IPIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Heat & Glo LifeStyle 8000CF-OAK-IPIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Heat & Glo LifeStyle 8000CF-OAK-IPIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHeat & Glo LifeStyle 8000CF-OAK-IPIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Heat & Glo LifeStyle 8000CF-OAK-IPIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHeat & Glo LifeStyle 8000CF-OAK-IPIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。