Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models DCM-750BAH(-OS) DCM-750BWH(-OS) Cubelet Icemaker / Dispenser Hoshizaki America, Inc.
2 IMPOR T ANT Only quali ed ser vice technicians should inst all, ser vice , and maintain the icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual.
3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 4 I. Specications .......................................................................................
4 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , or damage to the unit. W ARNING Indicates a hazar dous situation which could r esult in death or serious injury .
5 MODEL NUMBER DCM-750BAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
6 MODEL NUMBER DCM-750BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4 HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.
7 MODEL NUMBER DCM-750BWH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
8 MODEL NUMBER DCM-750BWH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
9 B. Dimensions/Connections 1 . DCM-750B AH Unit: in. [mm].
1 0 2. DCM-750BAH-OS Unit: in. [mm].
1 1 3. DCM-750BWH Unit: in. [mm].
1 2 4. DCM-750BWH-OS Unit: in. [mm].
1 3 Unit: in. (mm) 5. DCM-750BAH(-OS) or DCM-750B WH(-OS) on optional SD-70 0 or SD-750 Stand SD-70 0 34" (864) SD-750 34" (864) 6-1/8" (1 56) SD-70 0 26-1/2" (673) SD-750 26-3/4&q.
1 4 II. Installation and Operating Instr uctions W ARNING 1 . This icemaker must be inst alled in accor dance with applicab le national, stat e, and local regulations . 2. CHOKING HAZARD: Ensure all components, f astener s, and thumbscre ws are secur ely in place af ter inst allation.
1 5 T op P anel Side P anel Side P anel F ront P anel Apron P anel Connect or s B. How t o Remo v e Panels See F ig. 1 or Fig. 2 • F ront P anel: Remo ve the scr e w . Lif t up and tow ards you. Disconnect the connect ors on push-but ton models. • T op P anel: Lif t up at front slightl y , push rearw ard and lif t of f .
1 6 C. Location C A UTION 1 . This icemaker is not int ended f or outdoor use. Nor mal operating ambient temper atur e should be within 45°F t o 1 00°F (7°C to 38°C); Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 7 E. Electrical Connection W ARNING 1 . Electr ical connection must be har d-wired and must meet national, st at e, and local electrical code requir ements. F ailure t o meet these code requir ements could result in death, electric shoc k, serious injur y , re, or e xtensiv e damage to equipment.
1 8 F . W ater Suppl y and Dr ain Connections See F ig. 4, 5, or 6 W ARNING 1 . W ater suppl y and drain connections must be installed in accor dance with applicable national, st at e , and local r egulations. 2. Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 9 1 . Icemak er • Icemaker w ater suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the icemaker w ater supply line . • An icemaker w ater supply line shut-of f val v e and drain val ve should be installed.
20 Condenser W at er Supply Inlet 1/2" FPT Condenser Drain Outlet 3/8" FPT Icemaker W at er Supply Inlet 1/2" FPT Drip T ra y Drain Outlet 3/4" FPT 2. W at er -Cooled Condenser a) Connection to an Open Dr ain Sy stem • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT).
21 b) Connection to a Closed Loop S yst em • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the condenser wat er supply line. • Condenser r etur n outlet is 3/8" FPT .
22 G. F inal Chec klist W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er installation. Make sur e that none hav e f allen into the stor age bin.
23 H. Star t up W ARNING 1 . All par ts are f act or y -adjusted. Improper adjustments ma y adv er sely af fect saf ety , performance, component lif e, and warranty cov erage. 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor .
24 F ig. 8 9) Disengage the saf et y s witch. Mov e the control s witch to the "OFF" position, then mov e the pow er s witch to the "OFF" position. T ur n of f the power suppl y . 1 0) Clean the st orage bin liner and the st orage bin cov er using a neutral cleaner .
25 III. Cleaning and Maintenance W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er any cleaning or maint enance is done to the unit. Make sure that none ha ve f allen into the st orage bin. A.
26 1 . W ater S yst em a) Cleaning Solution Dilute 9.6 . oz. (0.29 l) of Hoshizaki "Scale A wa y" with 1 .6 g al. (6.0 l) of war m w at er .
27 1 3) Af t er the gear mot or star ts, mo ve the contr ol s witch to the "DRAIN" position and allow the wat er sy st em to dr ain f or 5 minutes . Note: If you do not sanitiz e the unit, mo v e the contr ol s witch to the "ICE" position af ter the wat er sy st em drains .
28 c) Cleaning and Sanitizing Pr ocedure 1) Mov e the control s witch to the "OFF" position, then turn off the po wer supply . 2) Remo ve the fr ont and t op panels, then mo ve the po wer s witch to the "OFF" position. 3) Remo ve the st orage bin co ver .
29 B. Maintenance This icemaker m ust be maintained individuall y , ref erring to the instruction manual and labels pro vided with the icemaker . The schedule below is a guideline. More fr equent maintenance , howe ver , may be r equired depending on wat er qualit y , the icemaker's envir onment, and local sanitation regulations .
30 C. Pr eparing the Icemak er f or Long Stor age C A UTION When st or ing the icemak er f or an ext ended time or in sub-freezing temper atur es , f ollow the instructions below to pr ev ent damage.
31 4) At tach a compressed air or carbon dio xide supply t o the condenser water suppl y line drain v alv e . 5) Open the wat er regulating v al v e b y using a scr e w driver t o pr y up on the spr ing r etainer under neath the spring.
32 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A2GE10B.
デバイスHoshizaki DCM-750BWH(-OS)の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki DCM-750BWH(-OS)をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki DCM-750BWH(-OS)の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki DCM-750BWH(-OS)の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki DCM-750BWH(-OS)で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki DCM-750BWH(-OS)を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki DCM-750BWH(-OS)の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki DCM-750BWH(-OS)に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki DCM-750BWH(-OS)デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。