Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Model DT-400BAH-OS Cubelet Icemaker / Dispenser Hoshizaki America, Inc. Issued: 2-28-2008 Revised: 6-14-2010 I N S T R U C T I O N .
2 IMPOR T ANT Only quali ed ser vice technicians should at t empt t o install, service, or maintain this icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual.
3 IMPOR T ANT This manual should be r ead car efull y bef ore the icemak er is installed and operat ed. Only quali ed ser vice technicians should inst all, ser vice, and maintain the icemak er . Read the w ar nings contained in this booklet car efully as they giv e impor tant inf or mation r eg ar ding saf et y .
4 I. Specications A. Nameplate Rating HOSHIZAKI ICE MAKER MODEL NUMBER DT-400BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 AMPERES 10.0 DESIGN PRESSURE HI-460PSI LO-290PSI REFRIGERANT 404A 1 LB 1 OZ MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc.
5 B. Dimensions / Connections Unit: mm [inch].
6 II. Installation and Operating Instr uctions A. Checks Bef ore Installation IMPOR T ANT 1 . Install in accor dance with all applicab le national, stat e, and local regulations . 2. Ensure all components, f astener s, and thumbscre ws are secur el y in place af ter installation.
7 C. Location C A UTION 1 . This icemaker is not int ended for outdoor use . Nor mal operating ambient temper atur e should be within +45°F t o +1 00°F (+7°C to +38°C); Nor mal operating w at er t emperatur e should be within +45°F to +90°F (+7°C to +32°C).
8 E. Electrical Connection See F ig. 2 W ARNING The GREEN gr ound wir e in the f actor y -installed pow er cor d is connect ed to a scr ew on the brac ket wher e the cor d ent er s the machine. If it becomes necessar y t o r emov e or replace the po wer cor d, be sure to connect the po wer cord’ s gr ound wir e to this scr ew upon r eat tachment.
9 F . W ater Suppl y and Dr ain Connections See F ig. 3 C A UTION T o pre vent damage t o the equipment, do not operat e this icemaker when the wat er supply is of f, or if the pr essure is belo w 1 0 PSIG. Do not r un the icemaker until the pr oper wat er pr essure is r eached.
1 0 G. F inal Chec klist 1) Is the icemaker le v el? 2) Is the icemaker in a sit e where the ambient t emperatur e is within +45°F to +1 00°F (+7°C to +38°C) and the w ater t emperatur e is within.
1 1 H. Star t up C A UTION 1 . All par ts are f actor y -adjusted. Improper adjustments ma y result in f ailure . 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor .
1 2 Contr ol Switch ("ICE", "OFF" or "DRAIN") Dispense Mode S witch ("POR TION" or "CONTINUOUS") Dispense Ice Sensor Dispense W at er Sensor Fig. 5 P ow er S witch "ON" and "OFF" Agit at or Mot or Dispensing Motor Fig.
1 3 I. Controls and A djustments 1 . P or tion Contr ol A v ariable r esist or which contr ols the amount of ice dispensed is locat ed on the contr ol board. The gures on the label indicat e dispensing time (sec.). When shipped, the por tion control is set at the minimum dispensing time (0.
1 4 III. Cleaning and Maintenance IMPOR T ANT Ensure all components , fast eners and thumbscre ws are secur el y in place af ter any maint enance or cleaning is done to the equipment. W ARNING 1 . Hoshizaki recommends cleaning this icemak er at least t wice a y ear .
1 5 8) Allow the icemak er to sit f or about 1 0 minutes bef ore oper ation. If you placed a clamp on the reservoir hose in st ep 7 , r emov e it befor e operation. 9) Plug the icemaker bac k in. Mov e the power s witch to the "ON" position and r eplace the panels in their correct positions .
1 6 8) Mov e the control s witch to the "OFF" position. Remo v e the upper fr ont, t op and lef t side panels. 9) Mov e the power s witch to the "OFF" postion.
1 7 Fig. 8 Fig. 9 B. Cleaning and Sanitizing Instructions - Dispensing Components P erf orm follo wing the cleaning and sanitizing pr ocedur es f or the water s yst em.
1 8 9) Immerse the parts remov ed in steps 4 thr ough 8 in the cleaning and sanitizing solutions f or about 1 5 minut es each. 1 0) Rinse these par ts thoroughl y with clean water . 1 1) Thor oughl y wipe the shut ter locat ed abov e the ice dispensing spout.
1 9 C. Maintenance IMPOR T ANT 1 . This icemaker m ust be maintained individuall y , r ef err ing to the instruction manual and labels pr o vided with the icemak er .
20 D . P reparing the Icemak er for Long St ora ge W ARNING When the icemak er is not used for t wo or thr ee day s under nor mal conditions, it is suf ficient t o onl y mov e the control s witch to the "OFF" position.
21 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A2KB10C.
デバイスHoshizaki DT-400BAH-OSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki DT-400BAH-OSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki DT-400BAH-OSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki DT-400BAH-OSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki DT-400BAH-OSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki DT-400BAH-OSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki DT-400BAH-OSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki DT-400BAH-OSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki DT-400BAH-OSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。