Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models KM-1400SWH/3-M Modular Crescent Cuber Hoshizaki America, Inc. Issued: 5-26-2010 I N S T R U C T I O N M A N U A L ™.
2 IMPOR T ANT Only quali ed ser vice technicians should inst all, ser vice , and maintain the icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual.
3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 4 I. Specications .......................................................................................
4 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , or damage to the unit. W ARNING Indicates a hazar dous situation which could r esult in death or serious injury .
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1 . KM-1 40 0SWH-M (water -cooled marine) See the nameplate f or electrical and refrigeration specications.
6 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT HOSHIZAKI ICE MAKER MODEL NUMBER KM-1400SWH3-M SERIAL NUMBER AC SUPPLY VOLTAGE 208-230/60/3 COMPRESSOR 208-230V 5.
7 B. Dimensions/Connections 1 . KM-1 40 0SWH/3-M (water -cooled marine) Unit: (mm) in. Note: When used with a stor age bin not r ecommended b y Hoshizaki, the icemak er needs the space at the bot tom opening as in the illustration.
8 II. Installation and Operating Instr uctions W ARNING 1 . This icemaker m ust be installed in accor dance with applicable int er national, national, stat e , and local r egulations. 2. CHOKING HAZARD: Ensure all components, f astener s, and thumbscre ws are secur ely in place af ter inst allation.
9 C. Location C A UTION 1 . This icemaker is not int ended for outdoor use . Nor mal operating ambient temper atur e should be within 45°F t o 1 00°F (7°C to 38°C); Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 0 5) Install the bin contr ol thermostat as f ollows: a. Remov e the baf f le fr om the bin. b . Remo v e the tie secur ing the bin control thermostat assemb l y . R emov e the 2 thumbscre ws. c. Remov e the bin control thermostat assembl y from the shipping hook b y lif ting it up and shif ting it to the right.
1 1 E. Installation of Second Unit 1) See "II.D . Setup" f or the lo wer unit inst allation. 2) Remo ve the t op panel and the t op insulation of the low er unit. The top panel and the t op insulation of the low er unit ar e not r equir ed when installing the second icemak er .
1 2 7) Remo ve the tie securing the upper unit's bin control thermostat assembl y . 8) Remo ve the bin contr ol thermostat assembl y from the shipping hook by lif ting it up and shif ting it to the right. 9) Remo ve the thermostat bulb at tachment (plastic) of the upper unit fr om the thermostat e xt ension brac ket (stainless).
1 3 F . Electr ical Connection W ARNING 1 . Electrical connection must be hard-wir ed and must meet international, national, stat e , and local electrical code requir ements . F ailure t o meet these code requir ements could result in death, electric shock, serious injur y , re , or se v ere damage t o equipment.
1 4 G. W at er Supply and Dr ain Connections See F ig. 9 or 1 0 W ARNING 1 . W at er suppl y and drain connections m ust be installed in accor dance with applicable int er national, national, stat e, and local r egulations. 2. Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 5 2. W at er -Cooled Condenser a) Connection to an Open Dr ain Sy stem • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" nominal copper wat er tubing is recommended f or the condenser water suppl y line.
1 6 b) Connection to a Closed Loop S yst em • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" nominal copper wat er tubing is recommended f or the condenser water suppl y line. • Condenser r etur n outlet is 3/8" FPT .
1 7 H. F inal Chec klist W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews are secur ely in place af ter inst allation. Make sur e that none ha v e f allen into the stor age bin.
1 8 I. Star t up W ARNING 1 . All par ts are f actor y -adjusted. Improper adjustments ma y adver sely af f ect saf ety , performance, component lif e, and warranty cov erage. 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor .
1 9 CL OSED Normal Icemaking Operation OPEN Cleaning and Sanitizing Operation (allows solution ow t o the inside of the evapor ator) III. Cleaning and Maintenance This icemaker m ust be cleaned and maintained in accor dance with the instr uction manual and labels pr o vided with the icemak er .
20 1 . Cleaning P r ocedur e 1) Dilute 27 . oz. (800 ml) of Hoshizaki "Scale A wa y" with 5 gal. (1 9 l) of war m w at er . 2) Remo ve all ice fr om the e vaporat or and the storage bin. Note: T o r emov e cubes on the ev aporat or , tur n of f the power suppl y and tur n it back on af ter 3 minut es.
21 22) Mov e the control s witch to the "W ASH" position. 23) Replace the fr ont panel in its correct position. 24) T ur n on the power suppl y to rinse of f the cleaning solution. 25) T ur n of f the po wer suppl y aft er 5 minutes . 26) Remo ve the fr ont panel and the insulation panel.
22 B. Maintenance This icemaker m ust be maintained individuall y , ref erring to the instruction manual and labels pro vided with the icemaker . W ARNING 1 . Only quali ed ser vice technicians should at tempt to service this icemaker . 2. Disconnect power bef ore ser vicing .
23 2. Drain the w at er tank: 1) T ur n of f the po wer suppl y , then r emov e the front panel. Mov e the control s witch t o the "OFF" position. 2) Remo ve the insulation panel. Remo v e the drain plug locat ed on the lower fr ont par t of the ice chute .
24 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A7DH10A.
デバイスHoshizaki KM-1400SWH/3-Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki KM-1400SWH/3-Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki KM-1400SWH/3-Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki KM-1400SWH/3-Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki KM-1400SWH/3-Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki KM-1400SWH/3-Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki KM-1400SWH/3-Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki KM-1400SWH/3-Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki KM-1400SWH/3-Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。