Modular Crescent Cuber Models KMD-410MAH KMD-410MWH INSTRUCTION MANUAL Issued: 7-5-2013.
1 IMPOR T ANT Only quali fi ed service technicians should install and service the appliance. T o obtain the name and phone number of your local Hoshizaki Certi fi ed Service Representative, visit www .hoshizaki.com. No installation or service should be undertaken until the technician has thoroughly read this Instruction Manual.
2 IMPOR T ANT This manual should be read carefully before the appliance is installed and operated. Read the warnings and guidelines contained in this manual carefully as they provide essential information for the continued safe use and maintenance of the appliance.
3 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury , damage to the appliance, or damage to property . W ARNING Indicates a hazardous situation which could result in death or serious injury .
4 W ARNING, continued • The appliance is not intended for use by persons (including children) with reduced physical, sensory , or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety .
5 I. Speci fi cations A. Electrical and Refrigerant Data The nameplate provides electrical and refrigerant data. The nameplate is located on the right side panel. For certi fi cation marks, see the nameplate. We reserve the right to make changes in speci fi cations and design without prior notice.
6 B. Dimensions/Connections 1. KMD-410MAH Unit: mm [inches].
7 2. KMD-410MWH Unit: mm [inches].
8 II. Installation and Operating Instructions W ARNING • Install in accordance with all applicable national, state, and local codes and regulations. • CHOKING HAZARD : Ensure all components, fasteners, and thumbscrews are securely in place after installation.
9 • Side Panel (R): Remove the screw . Slide forward slightly and lift off. • Front Insulation: Lift up slightly , and pull towards you. • T op Insulation: Push up at front corner , and pop off. C. Location NOTICE • This icemaker is not intended for outdoor use.
10 • In areas where water damage is a concern, install in a contained area with a fl oor drain. • Allow at least 6” (15 cm) clearance at the right side for proper air circulation and at least 12” (30 cm) clearance at top for ease of maintenance and/or service should they be required.
11 Fig. 3 Discharge Hose Float Switch Connector Pump Motor Connector Thumbscrews Snap T ab Pump Motor Bracket Fig. 4 Float Switch Pump Motor Cube Guide Snap T ab 6b) Dispenser Unit: Follow the dispenser unit, adapter kit, or top kit instructions for securing the icemaker .
12 6) Route the bin control lead through the hole in the base, then into the bushing provided. See Fig. 5. Fig. 6 Bin Control Collars Fig. 5 Bushing Bin Control Lead 7) While pulling up the bin control lead, hook the bin control on the right side interior wall.
13 1 1) Replace the water tank, cube guide, pump motor bracket, pump motor and fl oat switch in their correct positions until they snap in place. NOTICE Be sure to let the discharge hose pass behind the copper tube and connect it securely in position.
14 F . Electrical Connection W ARNING • Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury , fi re, or damage.
15 G. W ater Supply and Drain Connections - See Fig. 9, 10 or 1 1 W ARNING W ater supply and drain connections must be installed in accordance with applicable national, state, and local regulations. NOTICE • Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C).
16 1. Icemaker Icemaker W ater Supply Inlet Minimum Icemaker W ater Supply Line Size Icemaker Drain Outlet Minimum Icemaker Drain Line Size 1/2" Female Pipe Thread (FPT) 1/4" Nominal ID Copp.
17 2. W ater-Cooled Condenser a) Connection to an Open Drain System Condenser W ater Supply Inlet Minimum Condenser W ater Supply Line Size Condenser Drain Outlet Minimum Condenser Drain Line Size 1/2.
18 b) Connection to a Closed Loop System Condenser W ater Supply Inlet Minimum Condenser W ater Supply Line Size Condenser Return Outlet Minimum Condenser Return Line Size 1/2" Female Pipe Thread.
19 H. Final Checklist W ARNING CHOKING HAZARD : Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin.
20 I. Startup W ARNING All parts are factory-adjusted. Improper adjustments may adversely affect safety , performance, component life, and warranty coverage. NOTICE • If the unit is turned of f, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor .
21 14) T urn on the power supply to start the automatic icemaking process. 15) T o con fi rm bin control operation, press the bin control’s actuator paddle during the fi rst 5 minutes of the freeze cycle. The compressor and fan motor should de-energize within 15 seconds, then the drain valve should energize until the water tank empties.
22 3) T urn off the power supply . 4) Remove the front panel and move the control switch to the “SERVICE” position. Move the service switch to the “DRAIN” position. 5 ) Replace the front panel in its correct position and turn on the power supply for 2 minutes.
23 Fig. 12 Discharge Hose Float Switch Connector Pump Motor Connector Thumbscrews Snap T ab Pump Motor Bracket Fig. 13 Float Switch Pump Motor Cube Guide Snap T ab NOTICE Be sure to let the discharge hose pass behind the copper tube and connect it securely in position.
24 12) T urn on the power supply to start the washing process. 13) T urn off the power supply after 30 minutes. 14) Remove the front panel. 15) Move the service switch to the "DRAIN" position. 16) Replace the front panel in its correct position and turn on the power supply for 2 minutes.
25 2. Sanitizing Procedure - Following Cleaning Procedure 1 ) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with water (add approximately 0.9 fl . oz. (27 ml) to 1.8 gal. (6.8 lit.) of water). 2) Remove the front insulation. 3) Pour the sanitizing solution into the water tank.
26 B. Maintenance This icemaker must be maintained individually , referring to the instruction manual and labels provided with the icemaker . W ARNING • Only quali fi ed service technicians should service this icemaker . • T o reduce the risk of electric shock, do not touch the control switch with damp hands.
27 C. Preparing the Icemaker for Periods of Non-Use NOTICE • During extended periods of non-use, extended absences, or in sub-freezing temperatures, follow the instructions below to reduce the risk of costly water damage.
28 5) Replace the front panel in its correct position. 6) Remove all ice from the dispenser unit/storage bin. Clean the dispenser unit/storage bin using a neutral cleaner . Rinse thoroughly after cleaning. 7) Close the icemaker water supply line drain valve.
HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www .hoshizaki.com L1F043104.
デバイスHoshizaki KMD-410MAHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki KMD-410MAHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki KMD-410MAHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki KMD-410MAHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki KMD-410MAHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki KMD-410MAHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki KMD-410MAHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki KMD-410MAHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki KMD-410MAHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。