Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Model KML-700MWH-M Low-Profile Modular Crescent Cuber Hoshizaki America, Inc. Issued: 10-13-2009 I N S T R U C T I O N M A N U A L .
IMPORTANT Only qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
3 CONTENTS Important Safety Information ................................................................................................. 4 I. Specications ............................................................................................
4 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury.
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1. KML-700MWH-M (water-cooled marine) See the nameplate for electrical and refrigeration specications.
6 B. Dimensions/Connections 1. KML-700MWH-M (water-cooled marine) Unit: in. (mm).
7 II. Installation and Operating Instructions WARNING 1. This icemaker must be installed in accordance with applicable international, national, state, and local regulations. . CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation.
8 C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
9 E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet international, national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, re, or severe damage to equipment.
10 F. Water Supply and Drain Connections See Fig. 4 or 5 WARNING 1. Water supply and drain connections must be installed in accordance with applicable international, national, state, and local regulations. . Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
11 Fig. 4 KML-700MWH-M Connection to an Open Drain System 2. Water-Cooled Condenser a) Connection to an Open Drain System • Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
1 Condenser Return Line Shut-Off Valve Condenser Return Line Drain Valve Icemaker Drain Outlet 3/4" FPT Icemaker Water Supply Inlet 1/" FPT Fig. 5 Condenser Water Supply Inlet 1/" FPT Condenser Return Outlet 3/8" FPT Separate piping to approved drain.
13 G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/storage bin.
14 H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. . If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
15 III. Cleaning and Maintenance WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the dispenser unit/storage bin.
16 8) In bad or severe water conditions, clean the oat switch assembly as described below. Otherwise, continue to step 9. a. Remove the 3 screws securing the oat switch assembly, then remove the assembly. b. Remove the retainer rod from the bottom of the oat switch housing, then remove the oat.
17 2. Sanitizing Procedure - Following Cleaning Procedure 1) Dilute 1.5 . oz. (37 ml or .5 tbs) of a 5.5% sodium hypochlorite solution (chlorine bleach) with .5 gal. (9.5 l) of warm water. ) Remove the front insulation panel. 3) Pour the sanitizing solution into the water tank.
18 C. Preparing the Icemaker for Long Storage CAUTION 1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage.
19 3) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve. 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.
0 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1HL10A.
デバイスHoshizaki KML-700MWH-Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki KML-700MWH-Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki KML-700MWH-Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki KML-700MWH-Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki KML-700MWH-Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki KML-700MWH-Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki KML-700MWH-Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki KML-700MWH-Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki KML-700MWH-Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。