HoshizakiメーカーL1F015102の使用説明書/サービス説明書
ページ先へ移動 of 22
SELF-CONT AINED CRESCENT CUBER INSTRUCTION MANUAL KM-201BAH KM-260BAH KM-201BWH KM-260BWH L1F015102 (100109).
IMPORT ANT Only qualified service technicians should install, service and maintain the product. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
IMPORT ANT 1. This booklet is an integral and essential part of the product and should be handed over to the user . Read the warnings contained in this booklet carefully as they give important indications regarding the safety of the installation, use and maintenance.
1 I. Specifications A. Nameplate Rating Model Amperes Refrigerant Energy Star KM-201BAH 6.1 AMPS R404A 12.0 oz. Applicable KM-260BAH 7.6 AMPS R404A 12.7 oz. Applicable KM-201BWH 5.4 AMPS R404A 10.9 oz. Not applicable KM-260BWH 7.1 AMPS R404A 13.8 oz.
2 B. Dimensions/Connections 1. KM-201BAH Unit: mm [inches].
3 2. KM-260BAH Unit: mm [inches].
4 3. KM-201BWH Unit: mm [inches].
5 4. KM-260BWH Unit: mm [inches].
6 II. Installation and Operating Instructions A. Checks Before Installation * V isually inspect the exterior of the shipping container , and any severe damage noted should be reported to the carrier . IMPORT ANT 1. Remove shipping carton, tape(s) and packing.
7 C. Location W ARNING This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +32° C).
8 D. Electrical Connection W ARNING THIS APPLIANCE MUST BE GROUNDED. This icemaker requires a ground that meets the national and local electrical code requirements. T o prevent possible severe electrical shock injury to individuals or extensive damage to equipment , install a proper ground wire to this icemaker .
9 Fig. 2 Fig. 3 T apped Hole (Leg Mounting) Base from 6” (15.2 cm) to 7” (17.8 cm). Screw the legs tightly into the tapped holes in the base (see Fig. 3). Handle the icemaker carefully not to damage the exterior . F . W ater Supply and Drain Connections - See Figs.
10 * Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and the floor drain. * This icemaker should be installed in accordance with applicable national, state and local regulations.
11 W ater Supply Inlet 1/2” FPT Drain Outlet 3/4” FPT Fig. 5 KM-201BWH KM-260BWH Condenser W ater Outlet 1/2” FPT Condenser W ater Inlet 1/2” FPT Shut-off V alve Drain V alve Shut-off V alve T o approved floor drain T wo-inch (5 cm) air gap Drain Floor Separate piping to approved drain.
12 G. Final Checklist 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7° C to +38°C) and the water temperature within +45°F to +90°F (+7°C to +32°C) all year around? 3) Is there at least 2” (5 cm) clearance at the right side for proper air circulation and at least 0.
13 H. Startup CAUTION 1. All parts are factory-adjusted. Improper adjustments may result in failure. 2. If the unit is turned of f, wait for at least 3 minutes before restarting the icemaker to prevent damage to the Compressor .
14 III. Cleaning and Maintenance Instructions IMPORT ANT Ensure all components, fasteners and screws are securely in place after any maintenance or cleaning is done to the equipment . A. Cleaning W ARNING 1 . Hoshizaki recommends cleaning this unit at least once a year .
15 7) After 30 minutes, move the Control Switch to the “OFF” position. 8) Same as step 4. 9) Move the Control Switch to the “ICE” position to fill the W ater T ank with water . 10) After 3 minutes, move the Control Switch to the “SERVICE” position and the Service Switch to the “W ASH” position.
16 17) Wash the Bin Control Switch, W ater T ank, Float Switch, Cube Guide and Overflow Pipe by using a nylon scouring pad, brushes and the cleaning solution. In addition to the removed parts, also wash the bin liner and Bracket (L) (R) with the solution.
17 2 ) Soak the removed parts from step 17 above in a clean container containing the sanitizing solution. After allowing the parts to soak for 10 minutes, wash them with the solution. Also wash the bin liner , Bracket (L) (R) with the solution. 3) Discard the sanitizing solution and rinse the parts thoroughly with water .
18 * The Storage Bin is for ice use only . Do not store anything else in the bin. * Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly . * Clean the bin liner by using a neutral cleaner . Rinse thoroughly after cleaning. 3.
19 5) Allow the line to drain by gravity . 6) Attach compressed air or carbon dioxide supply to the potable water supply line Drain V alve. 7) Move the Control Switch to the “ICE” position. 8) Quickly blow the potable water supply line out using compressed air or carbon dioxide.
デバイスHoshizaki L1F015102の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hoshizaki L1F015102をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHoshizaki L1F015102の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hoshizaki L1F015102の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hoshizaki L1F015102で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hoshizaki L1F015102を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHoshizaki L1F015102の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hoshizaki L1F015102に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHoshizaki L1F015102デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。