SC450NX MP Server Rack/Pedestal Kit Installation Guide Order Number: 711917-001a.
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document.
Copyright 1998, Intel Corporation. All Rights Reserved..
.
v Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server.
vi CAUTIONS E LECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION : ESD can damage disk drives, add-in boards, and other components. This server can withstand normal levels of environmental ESD while hot -swapping SCSI hard disk drives. However, we recommend doing all procedures in this manual only at an ESD-protected workstation.
vii Equipment Rack Precautions WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs).
viii.
ix Contents Safety Guidelines Server Precautions ............................................................................................................... v Equipment Rack Precautions .............................................................
x.
11 Introduction The SC450NX MP server is designed to either stand upright (pedestal mode) or be mounted in a rack (rack mode). Figures 1 and 2 on page 12 show examples of these configurations. Before operation, you must purchase an adapter kit to configure the server for one of the two modes.
12 Table 1 . SC450NX MP Server Physical Specifications Specification Pedestal Mode Rack Mode Height 48.26 cm (19 inches) 7u Width 31.12cm (12.25 inches) 19 inch rack Depth 63.5cm (25 inches) 25 inches Weight 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum configuration 38.
13 Configuring for Rack Mount Before starting, please read “ Safety Guidelines ” on page v . Prepare the Slide Assemblies See Figure 3 . 1. Remove the slide assemblies from the kit. 2. Orient a slide assembly so that the smallest outer bar is facing down.
14 Prepare the Server Before you can install the server in the 19-inch equipment rack, you must install a bezel, handles, and the small bars of the slide assemblies onto the sides of the server. Attaching the Bezel Frame and Door To be installed in a rack, the server needs a bezel frame with rectangular cutouts where the chassis handles fit.
15 Attach the Small Bar of the Slide Assembly to the Server See Figure 4 . 1. Remove four screws from the kit. 2. While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server.
16 Prepare the Equipment Rack Before you can install the server in the 19-inch equipment rack, you must attach the center bar and large outer bar assemblies to the vertical rails of the rack.
17 Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack See Figure 6 . 1. Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack.
18 Install the Server in the Rack WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs).
19 1 Small outer bar 2 Center bar 3 Large outer bar 4 Safety latch Figure 7 . Installing the Server in the Rack.
20.
21 Configuring for Pedestal Mount Install Chassis Feet See Figure 8 . 1. Remove two system feet and two screws from the kit. 2. Each system foot has one screw hole and, on the opposite end, two slots that fit two tabs extending from the chassis wall. Orient the chassis foot to align these features with their corresponding parts of the chassis wall.
22 Install Bezel Frame and Door 1. Attach the bezel frame by inserting the tabs at the corner of the frame into their corresponding rectangular slots on the chassis.
23 Changing from Pedestal to Rack To change your server from pedestal mode to rack mode, you must complete two basic steps: removing the components of the pedestal mount, then configuring the server for a rack mount.
24 Exchange the Bezel Frame To be installed in a rack, the server needs a new bezel frame with rectangular cutouts where the chassis handles fit. You need to remove the old bezel frame and install the new one from the rack kit.
デバイスIntel SC450NXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Intel SC450NXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIntel SC450NXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Intel SC450NXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Intel SC450NXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Intel SC450NXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIntel SC450NXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Intel SC450NXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIntel SC450NXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。